Læs gratis den danske manual til Kitchen Brains Modularm 75LC (12 sider) i kategorien ukategoriseret. Denne vejledning er vurderet som hjælpsom af 14 personer og har en gennemsnitlig bedømmelse på 4.7 stjerner ud af 7.5 anmeldelser. Har du et spørgsmål om Kitchen Brains Modularm 75LC, eller vil du spørge andre brugere om produktet?

Side 1/12
®
Kitchen Brains © 2016 | www.KitchenBrains.com | 229-40072 E Page 1 of 12
24/7 Toll-Free Technical Support
1-800-243-9271
(from the U.S., Canada and the Caribbean)
Save the instructions
for future reference.
www.KitchenBrains.com
INSTALLATION &
OPERATING GUIDE
MODULARM 75LC Multi-Monitor
This document contains confidential information. The dissemination, publication, copying, or duplication of this document or the software described herein without prior written authorization is strictly prohibited.
Page 2 of 12
MODULARM 75LC Multi-Monitor Installation & Operating
NOTICES
Before you start, please read these instructions
thoroughly in order to obtain maximum benefit from
the capabilities that this product offers.
Thank you for purchasing the 75LC multi-monitor. The 75LC
integrates sophisticated function with easy operation.
Patented Autoset* Technology, combined with common
pre-programmed default settings eliminates the need for
manual programming in most applications. PAS-PRO
password programming allows for easy and secure custom
configuration. All product functions and accessories may be
used simultaneously or you may use only those required for
your application. A simple, 3 button user interface combined
with prioritized intuitive visual alarm display makes the 75LC
extremely user friendly.
OVERVIEW
75LC FUNCTIONS:
The 75LC offers the following functions: (Patented
Operation, other Patents Pending.)
1. HI & LO Temperature Alarm with Patented Autoset
Technology.
2. AC Failure Alarm with built-in rechargeable battery
and built in recharging circuitry.
3. Door Ajar Alarm. (Requires magnetic contacts. See
pg. 3)
4. Panic (Entrapment) Alarm (Requires optional IP-1
Illuminated Button See pg. 3)
5. Manual and patented timed light control.
6. HACCP monitoring. (additional equipment required)
7. Remote notification. (additional equipment required)
8. Built in audible alarm.
*What is Autoset?
Patented Autoset Technology selects the right alarm temp
setpoints for monitoring a cooler or a freezer automatically,
virtually eliminating the need for manual programming.
Common cooler and freezer setpoints are pre-loaded into
the 75LC. Autoset Setpoints are:
COOLER FREEZER
HI 42F (6C) HI 10F (-12C)
LO LO 30F (-1C) -20F (-29C)
Cooler setpoints are the default settings, used for cooler
monitoring. If the compartment is a freezer, Autoset
detects the lower compartment temperature and
automatically changes to the freezer setpoints. (Freezer
defaults won’t revert to cooler defaults if temperature rises.
Cooler defaults can be easily manually restored when
necessary.) Manually changing setpoints in the program
menu automatically disables Autoset.
THREE BUTTON USER INTERFACE:
Test (Up):
Lights (Prog):
Silence (Down):
WHILE IN RUN OR ALARM MODE
Test: Press to test and to view alarm
parameter settings.
Lights: Press to manually activate and
deactivate compartment
Silence: Press to acknowledge an
alarm.
WHILE IN PROGRAM MODE
Up: Press to increase and alarm
parameter values.
Lights: Press to select PAS-PRO™
preset and program menu options.
Down: Press to decrease alarm
parameter values.
VISUAL ALARM ANNUNCIATION:
NOTE the following:
1. During normal operation the monitored temp
displays constantly.
2. Any abnormal or alarm condition (except Panic
Alarm) alternates between monitored condition
display and monitored temp as follows: (In order
of priority.)
ALARM TYPE ABNORMAL
CONDITION
ALARM
CONDITION
PANIC ALARM [Non applicable] “HLP” + HLP”
DOOR AJAR Door Light On “Dor” +
Temperature
TEMP OUT OF
RANGE
“HI” or “LO +
Temperature
“HI” or “LO”
+ AL +
Temperature
AC POWER
FAILURE
“PF” +
Temperature
A single dot will
display
Panic Alarm Operation: Two types of Panic Alarm are
available:
Manual Panic Alarm – (Requires optional IP-1).
The alarm can be cleared by either pressing the
Silence button on the 75LC or by opening and
closing the door. (This requires door contacts).
Auto Panic Alarm – (Requires magnetic contacts,
and either or both of the following IP-1 & MD -1).
Auto Panic offers protection for persons who may
be hurt or disabled and cannot activate a Manual
Panic Alarm.
Kitchen Brains © 2016 | www.KitchenBrains.com | 229-40072 E
This document contains confidential information. The dissemination, publication, copying, or duplication of this document or the sof tware described herein without prior written authorization is strictly prohibited.


Produkt Specifikationer

Mærke: Kitchen Brains
Kategori: ukategoriseret
Model: Modularm 75LC

Har du brug for hjælp?

Hvis du har brug for hjælp til Kitchen Brains Modularm 75LC stil et spørgsmål nedenfor, og andre brugere vil svare dig




ukategoriseret Kitchen Brains Manualer

ukategoriseret Manualer

Nyeste ukategoriseret Manualer