Læs gratis den danske manual til Klein Tools NCVT-2 (8 sider) i kategorien Måleudstyr. Denne vejledning er vurderet som hjælpsom af 62 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 31.5 anmeldelser. Har du et spørgsmål om Klein Tools NCVT-2, eller vil du spørge andre brugere om produktet?

Side 1/8
NON-CONTACT VOLTAGE TESTER
(NCVT-2) OwNER’S MANuAL
Fig. 1
Locking tab
Lengüeta de fijación
Languette de
verrouillage
Probe
Punta de prueba
Sonde
Body /Cuerpo/Corps
Cap /Tapa/Capuchon
Power button
Botón de encendido
Interrupteur
Fig. 2
Gently push down on locking tab.
Empuje suavemente hacia abajo.
Appuyez doucement sur la languette de verrouillage.
AAAAAA
Fig. 4
While pushing down on tab, slide cap off body.
Mientras empuja hacia abajo sobre la lengüeta, deslice la
tapa hasta separarla del cuerpo.
Tout en appuyant sur la languette, faites glisser le capuchon
pour le détacher du corps du détecteur.
Align channel tabs on cap with slots on
tester body (one on each side of tester).
Alinee las lengüetas de canal ubicadas en la
tapa con las ranuras ubicadas en el cuerpo del
probador (una a cada lado del probador).
Alignez les languettes à profilés sur le
capuchon avec les fentes du corps du dé-
tecteur (une de chaque côté du détecteur).
Slide cap onto body.
Deslice la tapa
sobre el cuerpo.
Faites glisser le capuchon
sur le corps du détecteur.
Align locking tab with cap.
Alinee la lengüeta de fijación con la tapa.
Alignez la languette de verrouillage avec le capuchon.
Hold pocket-clip on cap close to tester body while sliding cap onto tester.
Sujete el clip para bolsillo ubicado en la tapa cerca del cuerpo del probador
mientras desliza la tapa sobre el probador.
Maintenez la pince-agrafe sur le capuchon à proximité du corps du détecteur
tout en faisant glisser le capuchon sur le détecteur.
Fig. 3
KLEIN TOOLS, INC.
Chicago, IL USA
© 2015
www.kleintools.com
139805 Rev. 01/15 B
DuAL RANGE
MANUAL DEL USUARIO DEL PROBADOR DE TENSIÓN
SIN CONTACTOS DE INTERVALO DUAL (NCVT-2)
DéTECTEUR DE TENSION SANS CONTACT À
DOUBLE PLAGE (NCVT-2) - MODE D’EMPLOI
ENGLISH
SYMBOLS ON TESTER:
Warning. Risk of electric shock.
Risk of danger. Important information: It is important that users of this tester read,
understand, and follow all warnings, cautions, safety information, and instructions in this manual
before operating or servicing this tester. Failure to follow instructions could result in death or
serious injury.
Double Insulated.
Equipment is designed to protect against transients from the primary supply level.
(i.e. - electricity meter or overhead/ underground utility service).
OPERATING INSTRUCTIONS:
Modes of operation:
The NCVT-2 can operate as a dual range (NCVT-2 mode) or single range (NCVT-1 mode) tester. In
NCVT-2 mode, the tester will light a steady blue LED in the tip to indicate power-on and dual range
mode. In NCVT-1 mode, the tester will light a steady green LED in the tip to indicate power-on and
single range mode.
Turn unit on:
Press and hold the power button for ½ second, then release. Listen for single-beep sound and
watch for a steady green or blue LED to illuminate in the tip of the tester. The tester is now
activated and is operational. Test on known live circuit to verify tester functionality. See Silent
mode for additional power-on options.
Turn unit off:
Press and hold the power button for ½ second then release. Listen for a double-beep sound and
watch the green or blue LED turn off. The tester is now deactivated and is not operational.
System self-test:
The “power on” blue or green LED visually confirms battery sufficiency, system integrity, and
operation/active mode. Always test on known live circuit to verify tester functionality prior to use.
Changing operation modes:
While the unit is powered on, press and hold the power button for 2 seconds. The power-on LED
will switch from blue to green or green to blue. The tester will start in whichever mode it was last
powered off in.
Checking for the presence of AC voltage:
Prior to use, test on known live circuit to verify tester functionality. Place tip of the tester near an
AC voltage and refer to the tables below for each mode:
NCVT-2 mode:
POWER-ON 12 TO 48 VOLTS AC 48 TO 1000 VOLTS AC
Audible
Single Beep Low-Pitched Pulsing Beeping Sound
High-Pitched Continuous Beeping Sound
Visual
Steady Blue LED
Blue LED Turns OFF and Red LED
Blinks (approx. 2-times per second).
Blue LED Turns OFF and Red LED
illuminates continuously.
NCVT-1 mode:
POWER-ON 12 TO 48 VOLTS AC 48 TO 1000 VOLTS AC
Audible
Single Beep No Sound
High-Pitched Continuous Beeping Sound
Visual
Steady Green LED Steady Green LED Green LED Turns OFF and Red LED
illuminates continuously.
In NCVT-2 mode, the tester will be more sensitive and will show voltage indication at a further
distance away from a high voltage source than in NCVT-1 mode. Use NCVT-1 mode in situations
where you expect the voltage source will be greater than 48V AC.
Low battery indication:
Scenario 1 – Powering on the tester: The “power on” LED in the tip of the tester changes from a
steady green or blue to a blinking green or blue and a series of beeping sounds is generated. The
tester then turns off. The unit is now deactivated and is not operational, the batteries require replace-
ment. To replace the tester batteries refer to the Maintenance section titled “Battery Replacement.”
Scenario 2 – Operating the tester: If the LED lights dim and the tone fades, the tester may require new
batteries. To replace the tester batteries refer to the Maintenance section titled “Battery Replacement.”
Auto Power Off:
After 4 minutes of non-use, the tester automatically powers off to conserve battery life. Listen for
a double-beep sound and watch the “power on” LED turn off. The tester is now deactivated and
is not operational.
Silent mode:
The tester can be operated with only visual indication of voltage. With the tester powered off, press
and hold the power button for 2 seconds then release.
MAINTENANCE:
Battery Replacement:
• Orient the tool/tester with the pocket-clip facing you.
• Gently depress the tab, Fig. 2, until you can slide the end-cap off the main body of the tester.
• Remove the batteries using caution to prevent damage or injury to the internal components.
• Replace with two 1.5V AAA or LR03 or NEDA 24A batteries.
• Place batteries into tester with the positive terminals facing the tip, Fig. 3.
• Carefully align and slide the end-cap to the body of the tester, Fig. 4. Push the cap until it is
fully seated (denoted by a clicking sound), Fig. 4.
• Note: Hold pocket-clip on cap close to tester body while sliding cap onto tester.
• Test on known live circuit to verify tester functionality.
CAT
IV


Produkt Specifikationer

Mærke: Klein Tools
Kategori: Måleudstyr
Model: NCVT-2

Har du brug for hjælp?

Hvis du har brug for hjælp til Klein Tools NCVT-2 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måleudstyr Klein Tools Manualer

Klein Tools

Klein Tools ET19 Manual

1 Januar 2025
Klein Tools

Klein Tools NCVT-6 Manual

28 December 2024
Klein Tools

Klein Tools ET18 Manual

21 September 2024
Klein Tools

Klein Tools VDV211-048 Manual

21 September 2024
Klein Tools

Klein Tools ET500 Manual

3 September 2024
Klein Tools

Klein Tools ET510 Manual

3 September 2024
Klein Tools

Klein Tools NCVT-3 Manual

3 September 2024
Klein Tools

Klein Tools NCVT-2 Manual

3 September 2024
Klein Tools

Klein Tools 45001 Manual

3 September 2024
Klein Tools

Klein Tools HVNCVT-1 Manual

3 September 2024

Måleudstyr Manualer

Nyeste Måleudstyr Manualer

Uni-T

Uni-T UT220 Manual

3 April 2025
Uni-T

Uni-T UT681C Manual

3 April 2025
Uni-T

Uni-T UT216C Manual

3 April 2025
Uni-T

Uni-T UT611 Manual

3 April 2025
Uni-T

Uni-T UT210D Manual

3 April 2025
Uni-T

Uni-T UT210C Manual

3 April 2025
Uni-T

Uni-T UT210B Manual

3 April 2025
Uni-T

Uni-T UT682 Manual

3 April 2025
Uni-T

Uni-T UT275 Manual

3 April 2025
Uni-T

Uni-T UT08A Manual

3 April 2025