Kramer KC-ON PREM Manual


Læs gratis den danske manual til Kramer KC-ON PREM (2 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 36 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 18.5 anmeldelser. Har du et spørgsmål om Kramer KC-ON PREM, eller vil du spørge andre brugere om produktet?

Side 1/2
KC-ONPREM Quick Start
P/N:
2900- 301595QS
Rev:
1
Scan for full manual
Step 1: Check what’s in the box
KC-ONPREM Hardware platform for Control On Prem
1 Power adapter and cord
1 Quick start guide
Step 2: Get to know your -ONPREM KC
#
Feature
Function
1
Power Button
Press to turn the on and o. unit
2
USB 2.0 Connector
Connect to a computer for upgrading rmware or connect a USB device. to
3
DC IN 19V Connector
Connects to the 19V DC power adapter.
4
HDMI OUT Connector
Connect to an HDMI display.
5
DP OUT Connector
Connect to a DisplayPort display.
6
USB 3.0 connectors
Connect to up to 2 USB devices.
7
USB 2.0 connectors
Connect to up to 2 USB devices.
8
LAN RJ-45 Connector
Connect to a Local Area Network (LAN) cable.
9
AUDIO
LINE OUT 3.5mm Mini Jack
Connect to an unbalanced stereo audio acceptor.
MIC IN 3.5mm Mini Jack
Connect to a microphone.
The terms HDMI, HDMI High-Denition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc.
Step 3: Mount -ONPREM KC
Install using one of the following methods: KC-ONPREM
Attach the rubber feet and place the unit on a at surface.
Mount the unit in a rack using the recommended rack adapter
(see www.kramerav.com/product/KC-ONPREM).
Ensure that the environment (e.g., maximum ambient temperature & air ow) is compatible for the device.
Avoid uneven mechanical loading.
Appropriate consideration of equipment nameplate ratings should be used for avoiding overloading of the circuits.
Reliable earthing of rack-mounted equipment should be maintained.
Maximum mounting height for the device is 2 meters.
Step 4: Connect inputs and outputs
Always switch OFF the power on each device before connecting it to your . KC-ONPREM
Connecting Keyboard, Mouse, and Display are optional for normal operation. a
To achieve specied extension distances, use the recommended Kramer cables available at . www.kramerav.com/product/KC-ONPREM
Using third-party cables may cause damage!
Step 5: Connect power
Connect the power cord to and plug it into the mains electricity.
KC-ONPREM
Safety Instructions (See for updated safety information)www.kramerav.com
Caution:
For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
There are no operator serviceable parts inside the unit.
Warning:
Use only the power cord that is supplied with the unit.
Disconnect the power and unplug the unit from the wall before installing.
Step 6: Operate -ONPREM KC
Note that -ONPREM setup requires a network with a DHCP server. KC
To set -ONPREM: KC
1. Connect a mouse, keyboard and monitor directly to . KC-ONPREM
2. Connect the LAN cable to your local Network.
Note that does not support conguring a static IP within the software. All IP reservations must be done by MAC KC-ONPREM
reservations within the local router. You may need to contact your IT manager to obtain this information.
3. Log into the O Prem OS system. (Username = kramer Password = KC_Brainware) n .
The IP address appears on the display.
4. - The distributed IP appears. Run the command “hostname I”.
5. Change the HOSTNAME:
Set the `HOSTNAME` variable in the `.env` le, for example., `HOSTNAME=192.168.1.2`.
6. -Install On-Prem after editing the .env le: Re
Run the command from the kramer-control-13062024 sudo ./install.sh “ ”
Upon completion of the installation, the following message appears: . “User exists with same username”}Done
7. Using the IP Address, access Kramer Control via port 8888
KC-ONPREM :
Enter http://${HOSTNAME}:8888’ to access Kramer Control as the default user ``no-reply@kramerav.com` and
using 'K#passw0rd as the default password.
For example, if the IP address is 192.168.1.2, connect to the manager via “ 8888”.http://192.168.1.2:
8. Change the default password as required.
The device is connected to the Manager and is ready for project programming.


Produkt Specifikationer

Mærke: Kramer
Kategori: Ikke kategoriseret
Model: KC-ON PREM

Har du brug for hjælp?

Hvis du har brug for hjælp til Kramer KC-ON PREM stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Kramer Manualer

Kramer

Kramer C-CU32/UC+H Manual

20 Februar 2025
Kramer

Kramer AD-RING Manual

3 Januar 2025
Kramer

Kramer VSM-4x4A Manual

19 December 2024
Kramer

Kramer VS-6464DN-EM Manual

19 December 2024
Kramer

Kramer VIA GO3 Manual

19 December 2024
Kramer

Kramer VS-8FDxl Manual

19 December 2024
Kramer

Kramer VA-4X Manual

19 December 2024
Kramer

Kramer VA-14 Manual

19 December 2024
Kramer

Kramer VS-48HDxl Manual

19 December 2024
Kramer

Kramer VS-44HDxl Manual

19 December 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer