Kurth Electronic KE2100 Manual


Læs nedenfor 📖 manual på dansk for Kurth Electronic KE2100 (16 sider) i kategorien Måling. Denne guide var nyttig for 3 personer og blev bedømt med 3.9 stjerner i gennemsnit af 2 brugere

Side 1/16
KE2100
Time Domain Reectometer
Version 2.0
© KURTH ELECTRONIC GmbH
All rights reserved, including translations.
All reprints and electronic copies, including excerpts, require prior written approval
of Kurth Electronic GmbH.
All of the brand names and trademarks cited herein are the property of their registered owners.
Operating Manual
Kurth Electronic GmbH | Muehleweg 11 | D 72800 Eningen u.A. GERMANY |
Tel. +49(0)7121 9755 0 | Fax +49(0)7121 9755 56 |
info@kurthelectronic.de | www.kurthelectronic.de
© Kurth Electronic GmbH, All Rights Reserved
2
Usage
The KE2100 is a handy and compact Time Domain Reectometer for fault
location for all types of cables without service, such as twin wires, coax and
power lines. It has a very short minimum resolution and a range of up to
14 km. The adjustable impedance and the editable shortening factor meet
all requirements for a successful test setup. The tester o󰀨ers simple and
intuitive operation.
With the AUTO test, a single click ensures that the impedance and length
specications correspond to the cable section to be tested, thus ensuring fast
diagnosis. With the clearly operable cursor a fast distance determination is
possible, this is additionally supported by a second cursor.
The freeze function allows you to examine the curve accurately, a feature
available on the very few TDRs in this price range. The high screen resolu-
tion with backlighting allows an accurate error evaluation of the trace. The
bundled management software manages the cable database and the stored
measurements can be examined in the intuitive interface.
At a glance
Simple operation
AUTO test for immediate use
High measurement resolution / maximum cable length up to 14 km
Menu language German or English
Indicates the distance to the error in meters or feet
Symmetrical search signal
Freezing function for precise error evaluation
Measurement curve as reference in the background
Preparation
Insert 4x AA alkaline batteries into the battery compartment on the back of
the unit. Only replace the batteries with the test cables removed. See page
13 for details.