Chauvin Arnoux C.A 6113 Manual


Læs gratis den danske manual til Chauvin Arnoux C.A 6113 (82 sider) i kategorien Måling. Denne vejledning er vurderet som hjælpsom af 5 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 3 anmeldelser. Har du et spørgsmål om Chauvin Arnoux C.A 6113, eller vil du spørge andre brugere om produktet?

Side 1/82
Installation tester
EN - User’s manual
C.A 6113
2
WARNING, risk of DANGER! The operator must refer to these instructions whenever this danger symbol appears.
Useful information or tip.
Current clamp.
Auxiliary rod.
Polarity of the supply connector with direct voltage.
The voltage on the terminals must not exceed 550 V.
The CE marking indicates compliance with the European Low Voltage Directive (2014/35/EU), Electromagnetic
Compatibility Directive (2014/30/EU), and Restriction of Hazardous Substances Directive (RoHS, 2011/65/EU and
2015/863/EU).
The UKCA marking certies that the product is compliant with the requirements that apply in the United Kingdom, in
particular as regards Low-Voltage Safety, Electromagnetic Compatibility, and the Restriction of Hazardous Substances.
The rubbish bin with a line through it indicates that, in the European Union, the product must undergo selective disposal
in compliance with Directive WEEE 2012/19/EU. This equipment must not be treated as household waste.
Denition of measurement categories
Measurement category IV corresponds to measurements taken at the source of low-voltage installations.
Example: power feeders, counters and protection devices.
Measurement category III corresponds to measurements on building installations.
Example: distribution panel, circuit-breakers, machines or xed industrial devices.
Measurement category II corresponds to measurements taken on circuits directly connected to low-voltage installations.
Example: power supply to electro-domestic devices and portable tools.
PRECAUTIONS FOR USE
This instrument complies with safety standard IEC/EN 61010-2-030 or BS EN 61010-2-030 for voltages of 600V category III or
300V in category IV (under shelter).
Failure to observe the safety instructions may result in electric shock, re, explosion, and destruction of the instrument and of the
installations.
Do not exceed the maximum rated voltage and current and the measurement category.
Never exceed the protection limits indicated in the specications.
Comply with the conditions of use, namely the temperature, the humidity, the altitude, the degree of pollution, and the place of use.
Do not use the device or its accessories if they seem damaged.
Do not use the device if the battery compartment cover is missing or incorrectly installed.
To recharge the battery, use only the mains adapter unit provided with the device.
To replace the battery, disconnect everything connected to the device and set the switch to OFF.
Do not use a battery with a damaged jacket.
Use connection accessories of which the overvoltage category and service voltage are greater than or equal to those of the
measuring device (600 V Cat. III or 300 V Cat. IV).
Troubleshooting and metrological checks must be done only by accredited skilled personnel.
Wear the appropriate protective gear.
Thank you for purchasing a C.A 6113 installation tester.
To obtain the best service from your unit:
read these operating instructions carefully,
comply with the precautions for use.


Produkt Specifikationer

Mærke: Chauvin Arnoux
Kategori: Måling
Model: C.A 6113

Har du brug for hjælp?

Hvis du har brug for hjælp til Chauvin Arnoux C.A 6113 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måling Chauvin Arnoux Manualer

Måling Manualer

Nyeste Måling Manualer

Megger

Megger Teleflex VX Manual

13 Oktober 2025
Megger

Megger SWG 1750 Manual

13 Oktober 2025
Megger

Megger DET4TR2 Manual

13 Oktober 2025
Megger

Megger MFT1735 Manual

12 Oktober 2025
Megger

Megger Baker NetEP Manual

12 Oktober 2025
Megger

Megger BT51 Manual

12 Oktober 2025
Megger

Megger Baker WinTATS Manual

12 Oktober 2025
Megger

Megger DLR0 10X Manual

12 Oktober 2025