Side 1/2
// LCT 840
QUICKSTART GUIDE
WHAT YOU SEE
IS WHAT YOU GET
SUPER-LOW SELF NOISE MULTI-PATTERN
TUBE MICROPHONE
// Overview
// Large diaphragm condenser tube microphone
// Multi-pattern microphone: omnidirectional, wide cardioid,
cardioid, supercardioid,  gure-8
// Noiseless pushbuttons for quick and easy attenuation and
low-cut  lter selection
// 4 low-cut settings: linear, 40 Hz (12 dB/oct), 150 Hz (6 dB/oct)
and 300 Hz (6 dB/oct)
// 3 pre-attenuation settings: 0 dB, -10 dB and -20 dB
// High dynamic range and low self-noise
// Custom power supply unit with illuminated user interface
for easy handling - even in dark environments
// Gold plated & corrosion-resistant 11-pin XLR socket
Top applications // Vocals, acoustic instruments
and wind instruments
// User interface
1 On/Off switch
2 Fuse
3 Mains socket
4 Mains voltage selection switch
5 3-pin XLR socket
6 11-pin XLR socket
7 Pre-attenuation indications
8 Pre-attenuation push button
9 Polar pattern selection
10 Status indicator ring
11 Low-cut lter indications
12 Low-cut lter push button
13 11-pin audio cable
41
10
11
12
7
8
5 6
3
2
13
9
READ THE
FULL MANUAL!
Learn Everything about your LCT 840
www.lewitt-audio.com/resources/manuals/LCT-840.pdf
Supply voltage: Custom power supply unit 230 V, 50 Hz 110 V, 60 Hz
Current consumption: 14.66 W
Connector: Gold plated 11-pin XLR
Cable: 5 m (16.40 ft) 11-pin audio cable oxygen-free copper
// LCT 840
QUICKSTART GUIDE
// Operating the microphone
Status indicator ring 10
Illuminated in white: The microphone is in normal working mode.
Illumination is off: Key-lock active.
Illumination ashes in red: The microphone is experiencing clipping due to high SPL.
Illumination in red: The microphone is in automatic attenuation mode.
Illumination ashes in white and red: The microphone indicates the clipping history.
Polar pattern indicator // 5 different directivity characteristics omnidirectional, wide cardioid, cardioid, supercardioid, gure-8
can be set by briey turning the jog-dial to the right or left 9 .
Setting an attenuation level // Attenuation levels can be set by briey pressing the left push button 8 .
Settings are: 0 dB, -10 dB and -20 dB. Attenuation is used in high SPL environments in order to prevent clipping of the
microphone, mixer and other audio equipment.
Setting a low-cut lter // Low-cut lters can be set by pressing the right push button 12 .
Settings are: linear, 40 Hz (12 dB/oct), 150 Hz (6 dB/oct) and 300 Hz (6 dB/oct). Low-cut lters eliminate unwanted low-frequency
sounds, compensate the proximity effect and reduce structure-borne noise. Do not forget to use the supplied windshield if
necessary.
To learn about the key-lock function, automatic attenuation and clipping history please read the full manual following the
link at the bottom.
// Please Note
// The capsule is a sensitive, high precision component. Make sure you do not drop it from high heights and avoid strong mechanical
stress and force.
// To ensure high sensitivity and best sound reproduction of the microphone, avoid exposing it to moisture, dust or extreme
temperatures. Use supplied windshield if suitable.
// Do not apply excessive force on the buttons or the connected cable.
// When disconnecting the microphone cable, grasp the connector and do not pull the cable.
// Do not attempt to modify or x the microphone, as it would void your product warranty.
// The casing of the microphone can be cleaned easily using a wet cloth, never use alcohol or another solvent for cleaning.
// The windshield can be washed with soap water, if necessary.
// IMPORTANT NOTICE!
// Never remove the mains earth, doing so can have lethal consequences.
// Replace fuse only with the same type.
// Only use indoors, in safe and dry environments.
// There are no user-serviceable parts inside the power supply unit, but there
are potentially lethal voltages. If it does not work correctly, you should consult your dealer. Do not open the unit yourself.
// Do not disconnect the microphone cable while the system is powered as this may result in damage to the microphone.
// Do not use with damaged cables or after unit has fallen and loose parts or broken glass can be heard inside.
// Do not cover the power supply unit, always leave enough space around it for proper ventilation.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired operation.
// Getting started
1 Make sure that the mains voltage selection switch 4 is set to the correct position depending on the country´s specic
mains electricity.
2 Use the 11-pin audio cable to connect the microphone with the 11-pin XLR socket on the backside of the PSU.
3 Use the 3-pin XLR cable to connect your mixer with the 3-pin XLR socket 5 on the backside of the PSU.
4 Put the LCT 840 into operation by activating the On/Off switch 1 on the backside of the PSU.
5 Let the tube warm up. Microphone reaches full sensitivity after 60 seconds.
6 Choose your settings.
7 You are ready to go!
LEWITT
®
Burggasse 79
1070 Vienna
Austria
www.lewitt-audio.com


Produkt Specifikationer

Mærke: Lewitt
Kategori: Mikrofon
Model: LCT 840

Har du brug for hjælp?

Hvis du har brug for hjælp til Lewitt LCT 840 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Mikrofon Lewitt Manualer

Lewitt

Lewitt LCT-240 Pro Manual

4 September 2025
Lewitt

Lewitt LCT 940 Manual

20 November 2024
Lewitt

Lewitt LCT 840 Manual

21 August 2024
Lewitt

Lewitt MTP 350 CM Manual

21 August 2024
Lewitt

Lewitt MTP 550 DM Manual

21 August 2024
Lewitt

Lewitt DTP 640 REX Manual

21 August 2024
Lewitt

Lewitt LCT 140 AIR Manual

21 August 2024
Lewitt

Lewitt MTP 250 DMs Manual

21 August 2024

Mikrofon Manualer

Nyeste Mikrofon Manualer

Kurzweil

Kurzweil Mangler Manual

15 September 2025
Kurzweil

Kurzweil KM-2U Manual

15 September 2025
Kurzweil

Kurzweil UNiTE-2 Manual

14 September 2025
AKG

AKG GN50 ESP Manual

12 September 2025
Karma

Karma SET 6090 Manual

12 September 2025
AKG

AKG HT45 Manual

12 September 2025
Karma

Karma SET 8202 Manual

12 September 2025
M-Audio

M-Audio Nova Manual

12 September 2025
Grimm Audio

Grimm Audio MP1 Manual

12 September 2025
Ipevo

Ipevo Vocal Manual

12 September 2025