Læs gratis den danske manual til Little Giant EC-1-DV (40 sider) i kategorien Vandpumpe. Denne vejledning er vurderet som hjælpsom af 2 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 1.5 anmeldelser. Har du et spørgsmål om Little Giant EC-1-DV, eller vil du spørge andre brugere om produktet?

Side 1/40
EC-1-DV & EC-1K-DV Series
OWNER'S MANUAL
English
EN
This pump is designed to automatically remove condensate water
that drips from wall mount ductless air conditioners up to 34,000
BTU/hr. The EC-1-DV pump is only suitable for intermittent use in
applications with a maximum 50% pump duty cycle and maxi-
mum 3-minute pump ON cycle. To maintain a maximum 50%
duty cycle, the pump must have at least twice the flow rate of the
condensate produced at the head required by the application.
The pump is controlled by a float switch mechanism, which auto-
matically starts and stops the pump. These models also include a
high water level switch, which opens a thermostat circuit or breaks power to the machine when the pump
reservoir is full, stopping production of condensate. Alternatively, this switch can be reconfigured to close a
circuit and operate a relay to sound an alarm, power a warning light, or signal a building management sys-
tem (alarm, light, and BMS are purchased separately).
This product is covered by a Limited Warranty for a period of 2 years from the date of original purchase by
the consumer. For complete warranty information, refer to www.LittleGiant.com
.
Specifications
Model
Item
Number
Volts Hz Amps Watts
EC-1-DV 553507
110-240 50/60 0.18 18
EC-1K-DV 553517
Model
Item
Number
Gallons (Liters) per Hour at Height
Shut Off
ft (m)
0 ft
(0.0 m)
1 ft
(0.3 m)
5 ft
(1.5 m)
10 ft
(3.0 m)
20 ft
(6.1 m)
EC-1-DV 553507
2.7 (10.2) 2.5 (9.5) 1.8 (6.8) 1.5 (5.7) 1.2 (4.5) 33 (10)
EC-1K-DV 553517
SAFETY INSTRUCTIONS
Specifications
2
SAFETY INSTRUCTIONS
This equipment should be installed and serviced by technically qualified personnel who are familiar
with the correct selection and use of appropriate tools, equipment, and procedures. Failure to comply
with national and local electrical and plumbing codes and within Little Giant recommendations may
result in electrical shock or fire hazard, unsatisfactory performance, or equipment failure.
Know the product’s application, limitations, and potential hazards. Read and follow instructions care-
fully to avoid injury and property damage. Do not disassemble or repair unit unless described in this
manual.
Failure to follow installation or operation procedures and all applicable codes may result in the follow-
ing hazards:
Risk of death, personal injury, or property damage due to explosion,
fire, or electric shock.
Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc.
Do not use in explosive atmospheres or hazardous locations as classified by the NEC, ANSI/NFPA70.
Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
When a pump is in its application, do not touch the motor, pipes, or water until the unit is unplugged or electrically disconnected.
If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of power.
Risk of severe injury or death by electrical shock.
To reduce risk of electrical shock, disconnect power before working on or around the system.
Wire pump system for correct voltage.
Be certain that this pump is connected to a circuit equipped with a ground fault circuit interrupter (GFCI) device if required by
code.
Check electrical outlets with a circuit analyzer to ensure power, neutral, and ground wires are properly connected.
These pumps are designed to be used with an earth-grounding conductor. To reduce the risk of electrical shock, connect the
earth lead to a properly-grounded circuit in accordance with electrical code.
Some pumps are supplied with lead wires and are intended to be hardwired using a junction box or other approved enclosure.
The pumps include a grounding connector. To reduce risk of electric shock, be certain that it is properly connected to ground.
All wiring must comply with the National Electrical Code and local codes.
Check local electrical and building codes before installation. The installation must be in accordance with their regulations as well
as the most recent National Electrical Code (NEC) and the Occupational Safety and Health Association (OSHA).
Do not use the power cord for lifting the pump.
Do not use an extension cord.
The pump should only be used with liquids compatible with pump component materials. If the pump is used with liquids incom-
patible with the pump components, the liquid can cause failure to the electrical insulation system resulting in electrical shock.
This pump has not been investigated for use in swimming pool or marine areas.
To reduce risk of electric shock, install with all electrical components above the top grade level of the pump.


Produkt Specifikationer

Mærke: Little Giant
Kategori: Vandpumpe
Model: EC-1-DV

Har du brug for hjælp?

Hvis du har brug for hjælp til Little Giant EC-1-DV stil et spørgsmål nedenfor, og andre brugere vil svare dig




Vandpumpe Little Giant Manualer

Vandpumpe Manualer

Nyeste Vandpumpe Manualer

Vonroc

Vonroc SP510DC Manual

24 August 2025
Vonroc

Vonroc GP530AC Manual

23 August 2025
Vonroc

Vonroc GP529AC Manual

23 August 2025
Vonroc

Vonroc GP528AC Manual

23 August 2025
DAB

DAB Nova Manual

23 August 2025
DAB

DAB Nova 4100 Manual

23 August 2025
Generac

Generac ST20K Manual

22 August 2025
Generac

Generac CW10K Manual

22 August 2025
Generac

Generac CW15K Manual

22 August 2025