Mach Power SW-UG8P2LV-059 Manual


Læs gratis den danske manual til Mach Power SW-UG8P2LV-059 (2 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 15 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 8 anmeldelser. Har du et spørgsmål om Mach Power SW-UG8P2LV-059, eller vil du spørge andre brugere om produktet?

Side 1/2
Features
Comply with IEEE802.3, IEEE802.3ab, IEEE802.3u,IEEE802.3az, IEEE802.3af/at standards
Support IEEE802.3x full-duplex flow control; support Auto MDI/MDIX
8 Port support 48V-56VDC power to PoE powered devices
Provide 15.4W or 30W power to powered devices
Extra 2-Port 10/100/1000Mbps UPLINK RJ-45
120 watts PoE budget
PoE data & power transmission distance up to 100meters
Port based VLAN for Enhanced Security
Excellent anti-thunder, anti-static and anti-interference ability
Surge Protection: 6KV
Restart function helps master IC reset wholly
Easy and convenient to use, plug & play, no need to configure
Galvanized housing for stable and durable working life
Overview
The SW-UG8P2LV-059 provides 8 port 10/100/1000Mbps IEEE 802.3af/at Power over
Ethernet with a total of 120 watts of PoE budget, which is an ideal solution to fulfill the
demand of sufficient PoE power for network applications.
The SW-UG8P2LV-059 is an ideal solution for securing IP surveillance infrastructure. It
provides both 802.3af/at PoE functions along with 8 x 10/100/1000Base-TX ports
featuring 15.4 watts 802.3af/30 watts 802.3at PoE in RJ-45 interfaces and extra 2 x
10/100/1000Mbps UPLINK RJ- 45 port to keep a cascade connection with another switch
or NVR. For instance, one SW-UG8P2LV-059 can be combined with one 8 Channel NVR
and 8 PoE IP cameras as a kit for the administrators to centrally and efficiently manage
the surveillance system in the local LAN and the remote site via Internet.
With data and power over Ethernet from one unit, the SW-UG8P2LV-059 reduces cabling
requirements and eliminates the need for dedicated electrical outlets on the wall, ceiling
or any unreachable place. A wire that carries both data and power can lower the installa-
tion costs, simplify the installation effort and eliminate the need for electricians or
extension cords. Providing 8 PoE interfaces, the SW-UG8P2LV-059 is ideal for small
businesses and workgroups requiring deploying the PoE for the wireless access points,
IP-based surveillance IP phones in any places easily, efficiently and cost-effectively.
visit our website
www.machpower.it
USER MANUAL SW-UG8P2LV-059
Front panel
1. Rack-mounting ears: Cabinets for product installation or Wall installation
2. Power indicator: Red Light on: with power; Light off: no power
3. PoE indicator: Yellow Light on: when device is powered
Light off: when device is not detected or not powered
4. Link/ Act Indicator: Green LED on: link up
Green LED off: link down
Green LED blinks: data transfer
5. Downlink Port: Transfer data from other IP devices to the switch
6.Uplink Indicator: Green LED on: link up
Green LED off: link down
Green LED blinks: data transfer
Yellow LED on: link speed is 10/100/1000Mbps
Yellow LED off: link speed is 10/100Mbps
7. Uplink Port: Transfer data from PoE ports to other devices (NVR/Switch/ADSL)
Rear panel
1. Reset button: Press the reset button to turn on indicator and the device restarts
2. Reset button indicator: Green
3. LAN Button: Turn on VLAN button: indicator on and VLAN function starts
Turn on VLAN button: indicator off and VLAN function stops
4. VLAN Indicator: Green
5. Ground Connection
6. Input: DC 48~56V
Technical Specification
How to make a network cable
To create a network cable, you will first need the equipment listed below.
1. Cat5e, Cat6, or Cat7 cable
2. RJ-45 connectors
3. Crimping tool
3. Wire stripper or knife
1. We recommend stripping at least a half of an inch offf the cable to expose the inner
wires.
2. Separate the wires within the cable after the network cable jacket has been removed
so that they can be put into the RJ-45 connector
3. The CAT5 twisted-pair cable consist of four twisted wires, each color coded; 8 wires
must be correctly lined as the standards of EIA/TIA 568A or EIA/TIA568B
4. Cut thread residue and leave 1.5cm wire exposed outside the insulating layer and
ensure 8 wire are straighten and neat.
5. Place the cable into the RJ-45 connector and use the crimping tool to attach the
connector.
6. Repeat above steps for the other end of the cable; the wire sequence of both ends of
the cable is suggested to be identical.
7. Make sure to test the cables before installing them once both ends of the cable have
been completed.
Note:
1. All RJ-45 Ports of this device support Auto MDI/MDIX, so the different wire
sequence of both enads of the cable is allowed.
T568A
T568B
1
white
greeen
white
orange
2
greeen
orange
3
white
orange
white
green
4
blue
blue
5
white
blue
white
blue
6
orange
green
7
white
brown
white
brown
8
brown
brown
The wire sequence of RJ45 connector must
comply with internaonal standard of EIA/TIA
568A or EIA/TIA 568B.
MODEL
Product name
Power Supply
Network port
parameter
Network switch
specification
Indicator
SW-UG8P2LV-059
8 ports 10/100/1000Mbps IEEE 802.3af/at PoE switch
Power Supply mode
Voltage range
Power consumption
Network Port
Transmission distance
Transmission medium
PoE standard
PoE power supply mode
PoE power supply wattage
Network standards
Swap mode
Data-caching mechanism
MAC address list
Throughput
Power indicator
Uplink RJ45 port indicator
PoE indicator
PoE network port indicator
Power adaptor
AC 48~56V
The device 8W <
PoE power supply 120W
Ethernet downlink RJ45 port : 8 x 10/100/1000Mbps
Uplink port: 2 x 10/100/1000Mbps
Downlink port: 100m
Uplink port: 100m
Downlink port: Cat5e/6 standard cable
Uplink port: Cat5e/6 standard cable
IEEE802.3 af/at standard
End-span method
Each port 8W
Whole device 120W
IEEE802.3, IEEE802.3ab,
IEEE802.3u,
IEEE802.3az
Store and forward
1.5M
4K
14.88Mbps
Red led on: power on
Green led > on: link up / off: link down / blinks:
data transfer
Yellow LED on: link speed is 1000Mbps
Yellow LED off: link speed is 10/100Mbps
8 PoE indicator (yellow)
8 port indicators blink white data transfer
Indicator
Button
Protection level
Reliability
Mechanical
Environmental
Reset indicator
VLAN Indicator
Reset button
VLAN button
Surge protection
Electrostatic protection
Mean time btw failures
Dimension (mm)
Housing
Body color
Net weight
Operating temperature
Storage temperature
Relative Humidity
Green light on when press reset button
Green light on when press VLAN button
Press the reset button and the device restarts
Turn on VLAN on: indicator on and VLAN restarts
Turn o ffVLAN on: indicator off and VLAN stops
6KV (common mode), 10/700us IEC61000-4-5
2KV (differential mode), 10/700us IEC61000-4-5
Contact Discharge: ±4KV
Air Discharge: ±6KV
Standard:IEC61000-4-2
>50.000h
219.6L x 105W x 27.6H
Galvanized
Black
612g
C 55°C~
-40°C 85°C~
0~ 95% (non-condensing)
Quick Setup Guide
Step1: Begin with all input/output devices turned off with power cables removed
Step2: Connect RJ-45 port of PoE cameras with Downlink RJ-45 port of PoE
switches in standard Cat 5e/6 cables
Step3: Connect with Uplink RJ-45 port of PoE switches with RJ-45 port of NVR
or computer or other devices in standard Cat 5e/6 cables
Step4: Input AC power cord into power socket of PoE switch
Step5: Make sure above connection is properly finished, then turn on power
VLAN Introduction
At present, applications of Ethernet switch is very wide. To satisfy the needs of various
customers, it is urgent for network services to solve the problems of broadcast domains,
bandwidth and security, so a new kind of technology of VLAN emerged.
Each DOWNLINK RJ-45 port and UPLINK RJ-45 ports form a separate workstation
respectively. In the same VLAN workstation, regardless of which switch they are actually
connected to, the communication between them is as if they were on a separate switch.
Broadcasts in the same VLAN can only be heard by members of the VLAN, but not in
other VLANs, which can control the generation of unwanted broadcast storms. At the
sam me, if there is no roung, different VLANs cannot communicate with each other,
which increases the security of different departments in the enterprise network.
When the VLAN mode is enabled, the data cannot be forwarded among DOWNLINK
RJ-45 ports, but DOWNLINK RJ-45 ports and UPLINK RJ-45 ports can communicate
with each other. The bandwidth of UPLINK RJ-45 port is 1000Mbps, which keeps a
cascade connection with another switch or NVR.
Note:
After you turn on VLAN button, please press reset button or reboot power the
device, then VLAN mode is enabled.


Produkt Specifikationer

Mærke: Mach Power
Kategori: Ikke kategoriseret
Model: SW-UG8P2LV-059

Har du brug for hjælp?

Hvis du har brug for hjælp til Mach Power SW-UG8P2LV-059 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Mach Power Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer