© 2025 MERCUSYS 7100000114 REV1.2.1
LED Explanation
Note: For simplicity, we will take MS108GP for example. Your product may dier from the depicted.
Switch Explanation
O: Ports run at 1000/100/10 Mbps (100/10 Mbps for MS110P, MS110CP and
MS110CMP) and support PoE power supply up to 100m away.
On: Ports run at 10 Mbps and support PoE power supply up to 250m away.
Extend
O: The PoE Auto Recovery function is disabled.
On: The switch will constantly detect the working status of a PoE powered device (PD).
When the switch nds that the PD works abnormally, the switch will reboot it.
Recovery
O: Ports can transmit data with each other.
On: The isolated ports cannot transmit data with other downlink ports. They can transmit
data only with the uplink ports (port 5 of MS105GP/port 8 of MS108GP/ports 9-10 of
MS110P, MS110CP and MS110CMP).
Isolation
PoE Switch
Quick Installation Guide
DC AP er ow dapter
AC Power Cord
Connection
PC
Ethernet Ports (1-8)
PoE Ports (1-7)
1. PoE ports can also connect to non-PoE devices, but only transmit data.
2. Non-PoE ports (port 5 of MS105GP/port 8 of MS108GP/ports 9-10 of MS110P,
MS110CP and MS110CMP) are recommended to connect to uplink devices like
gateways.
3. Ports 1-2 have higher priority than other ports in transmitting data if network
congestion occurs. It is recommended to connect key network devices (network
cameras, APs, etc.) to ports 1-2 (not for MS110CP or MS110CMP).
Notes:
Internet
IP Camera AP IP Phone
Powered Device (PD)
Power
On: The power is on
O: The power is o
Link/Act
On:
Link present but no activity
Flashing:
Transmitting or receiving data
O:
No link
PoE Status
On:
PoE power provided
O:
No PoE power provided
Note: For MS108GP, the Power LED is on the top right of port 8.

Mercusys hereby declares that the device is in compliance with the essential
requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU,
2011/65/EU and (EU)2015/863.
The original EU declaration of conformity may be found at
https://www.mercusys.com/en/ce/
EU declaration of conformity
General Specications
Specications
IEEE 802.3i, IEEE 802.3u, IEEE 802.3x (for all models)
IEEE 802.3ab, IEEE 802.1p (only for MS105GP and MS108GP)
CSMA/CD. 802.3af/at PD supported
MS105GP:
5 1000 Mbps RJ45 Ports Auto-Negotiation/Auto MDI/MDIX
PoE Ports: Port 1–4
MS108GP:
8 1000 Mbps RJ45 Ports Auto-Negotiation/Auto MDI/MDIX
PoE Ports: Port 1–7
MS110P:
10 10/100 Mbps RJ45 Ports Auto-Negotiation/Auto MDI/MDIX
PoE Ports: Port 1–8
MS110CP/MS110CMP:
8 10/100 Mbps RJ45 Ports Auto-Negotiation/Auto MDI/MDIX
2 1000 Mbps RJ45 Ports Auto-Negotiation/Auto MDI/MDIX
10BASE-T: 2-pair UTP/STP (≤100m) of Cat. 3 or above
100BASE-TX: 2-pair UTP/STP (≤100m) of Cat. 5 or above
1000BASE-T: 4-pair UTP/STP (≤100m) of Cat. 5e or above
(except for MS110P)
MS105GP: 10 Gbps
MS108GP: 16 Gbps
MS110P: 2 Gbps
MS110CP/MS110CMP: 5.6 Gbps
Store-and-Forward
Automatically learning, automatically aging
External Power Adapter
Input:
NV models: 220-240 VAC, 50/60 Hz
UN models: 100-240 VAC, 50/60 Hz
Output:
MS110CMP: 54 VDC/2.22 A
Other models: 53.5 VDC/1.31 A
MS110CMP: 115 W (up to 30 W for each PoE port)
Other models: 65 W (up to 30 W for each PoE port)
CE, RoHS
Standard
Interface
Protocol
Frequently Asked Questions (FAQ)
The Power LED should be lit when the power system is working normally. If the Power
LED is not lit, please check as follows:
A1:
Make sure the AC power cord/power adapter is connected the switch with power
source properly.
A2:
Make sure the voltage of the power supply meets the requirements of the input
voltage of the switch.
A3:
Make sure the power source is on.
Q1. Why is the Power LED not lit?
It is recommended that you check the following items:
A1:
Make sure that the cable connectors are rmly plugged into the switch and the
device.
A2:
Make sure the connected device is turned on and working well.
A3:
The cable must be less than 100 meters long (328 feet). If Extend Mode is enabled,
it should be less than 250 meters (820 feet).
Q2. Why is the Link/Act LED not lit when a device is
connected to the corresponding port?
When the total power consumption of connected PoE devices exceeds the maximum,
the PoE port with a smaller port number has a higher priority. The system will cut o
power to the ports with larger port numbers to ensure supplying to other ports.
Take MS108GP as an example. If port 1, 2 and 4 are consuming 18 W respectively, and
an additional PoE device with 15 W is inserted to port 3, the system will cut o the
power of port 4 to compensate for the overload.
Q3. Why are PoE ports not supplying power for PoE devices?
A1:
Before upgrading a connected PoE powered device (PD), disable PoE Auto
Recovery to avoid the PD’s damage.
A2:
When a PD does not send data packets to the switch for a long period in certain
scenarios (e.g. an IPC in sleep mode), disable PoE Auto Recovery to avoid the PD
repeatedly rebooting.
Q4. What should I notice before using the PoE Auto Recovery
feature?
Network Media (Cable)
Switching Capacity
Power Supply
Forwarding Method
MAC Address Learning
PoE Budget
Environmental and Physical Specications
CE, RoHS
-10˚C to 40˚C (14˚F to 104˚F)
-40˚C to 70˚C (-40˚F to 158˚F)
10% to 90% non-condensing
5% to 90% non-condensing
Certication
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Mercusys hereby declares that the device is in compliance with the essential
requirements and other relevant provisions of the Electromagnetic Compatibility
Regulations 2016 and Electrical Equipment (Safety) Regulations 2016.
The original UK declaration of conformity may be found at
https://www.mercusys.com/support/ukca/
UK declaration of conformity
For technical support, replacement services, user guides, and other information,
please visit https://www.mercusys com/support/..
Safety Information
Keep the device away from water, re, humidity or hot environments.
Do not attempt to disassemble, repair, or modify the device. If you need service,
please contact us.
Place the device with its bottom surface downward.
Do not use damaged charger or USB cable to charge the device.
Do not use any other chargers than those recommended.
Adapter shall be installed near the equipment and shall be easily accessible.
The plug on the power supply cord is used as the disconnect device, the
socket-outlet shall be easily accessible.
The PoE ports shall not be used to charge lithium batteries or devices supplied by
lithium batteries.
The socket-outlet shall be near the equipment and shall be easily accessible.
Plug the product into the wall outlets with earthing connection through the power
supply cord.
For MS110CMP only:
Certication
Produkt Specifikationer
Mærke: | Mercusys |
Kategori: | Ikke kategoriseret |
Model: | MS110CMP |
Har du brug for hjælp?
Hvis du har brug for hjælp til Mercusys MS110CMP stil et spørgsmål nedenfor, og andre brugere vil svare dig
Ikke kategoriseret Mercusys Manualer

4 Juni 2025

4 Juni 2025

3 Juni 2025

3 Juni 2025

3 Juni 2025

3 Januar 2025

24 December 2024

23 December 2024

3 September 2024

2 September 2024
Ikke kategoriseret Manualer
- Ikke kategoriseret Nintendo
- Ikke kategoriseret Donexon
- Ikke kategoriseret Lancom
- Ikke kategoriseret Scandes
- Ikke kategoriseret Peterson
- Ikke kategoriseret Tycon Systems
- Ikke kategoriseret USL
- Ikke kategoriseret Hifonics
- Ikke kategoriseret Skaarhoj
- Ikke kategoriseret Besco
- Ikke kategoriseret Profoon
- Ikke kategoriseret Razorri
- Ikke kategoriseret Vtech
- Ikke kategoriseret ISpring
- Ikke kategoriseret Rommer
Nyeste Ikke kategoriseret Manualer

4 Juni 2025

4 Juni 2025

4 Juni 2025

4 Juni 2025

4 Juni 2025

4 Juni 2025

4 Juni 2025

4 Juni 2025

4 Juni 2025

4 Juni 2025