1. PoE ports can also connect to non-PoE devices, but only transmit data.
2. Non-PoE ports (ports 5-6 of MS106LP/MS106P and uplink ports of MS110GMP) are
recommended to connect to uplink devices like gateways.
3. By default, ports 1-2 of MS106LP/MS106P have higher priority than other ports in
transmitting data if network congestion occurs. It is recommended to connect key network
devices (network cameras, APs, etc.) to ports 1-2.
On: Link present but no activity
Flashing: Transmitting or receiving data
O: Not providing PoE power
Link/Act; Uplink 1, Uplink 2
Green On: Running at 1000 Mbps, but no
Green Flashing: Running at 1000 Mbps and
is transmitting or receiving data.
Yellow On: Running at 10/100 Mbps, but no
Yellow Flashing: Running at 10/100 Mbps
and is transmitting or receiving data.
O: Ports run at100/10 Mbps (1000/100/10 Mbps for MS110GMP) and support PoE
power supply up to 100m away.
On: Ports run at 10 Mbps and support PoE power supply up to 250m away.
Extend (For MS106LP/MS106P/MS110GMP)
O: The PoE Auto Recovery function is disabled.
On: The switch will constantly detect the working status of a PoE powered device (PD).
When the switch nds that the PD works abnormally, the switch will reboot it.
Recovery (For MS106LP/MS106P/MS110GMP)
O: Ports can transmit data with each other.
On: The isolated ports cannot transmit data with each other. They can transmit data only
with the uplink ports (ports 5-6 of MS106LP and MS106P/uplink ports of MS110GMP).
Isolation (For MS106LP/MS106P/MS110GMP)
O: All the ports transmit data with the same priority.
On: The specic ports transmit data with a higher priority than other ports.
Priority (Only for MS110GMP)
The images in this guide are for demonstration only and may differ from your actual product.
© 2025 MERCUSYS 7100000115 REV1.2.1
MS106LP/MS106P: MS110GMP:
O: Not providing PoE power
On: 104 W≤Total power supply < 111 W
Flashing: Total power supply ≥ 111 W
O: Total power supply < 104 W