Mercusys MS110GMP Manual
Mercusys
Ikke kategoriseret
MS110GMP
Læs nedenfor 📖 manual på dansk for Mercusys MS110GMP (3 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 4 personer og blev bedømt med 4.3 stjerner i gennemsnit af 2.5 brugere
Side 1/3

LED Explanation
MS106LP/MS106P/MS110GMP
Quick Installation Guide
Connection
PC
PoE Ports
1. PoE ports can also connect to non-PoE devices, but only transmit data.
2. Non-PoE ports (ports 5-6 of MS106LP/MS106P and uplink ports of MS110GMP) are
recommended to connect to uplink devices like gateways.
3. By default, ports 1-2 of MS106LP/MS106P have higher priority than other ports in
transmitting data if network congestion occurs. It is recommended to connect key network
devices (network cameras, APs, etc.) to ports 1-2.
Notes:
Internet
IP Camera AP IP Phone
Powered Device (PD)
Power
On: The power is on
O: The power is o
Link/Act Status
On: Link present but no activity
Flashing: Transmitting or receiving data
O: No link
PoE Status
On: Providing PoE power
O: Not providing PoE power
Link/Act; Uplink 1, Uplink 2
Green On: Running at 1000 Mbps, but no
activity.
Green Flashing: Running at 1000 Mbps and
is transmitting or receiving data.
Yellow On: Running at 10/100 Mbps, but no
activity.
Yellow Flashing: Running at 10/100 Mbps
and is transmitting or receiving data.
O: No link
Switch Explanation
O: Ports run at100/10 Mbps (1000/100/10 Mbps for MS110GMP) and support PoE
power supply up to 100m away.
On: Ports run at 10 Mbps and support PoE power supply up to 250m away.
Extend (For MS106LP/MS106P/MS110GMP)
O: The PoE Auto Recovery function is disabled.
On: The switch will constantly detect the working status of a PoE powered device (PD).
When the switch nds that the PD works abnormally, the switch will reboot it.
Recovery (For MS106LP/MS106P/MS110GMP)
O: Ports can transmit data with each other.
On: The isolated ports cannot transmit data with each other. They can transmit data only
with the uplink ports (ports 5-6 of MS106LP and MS106P/uplink ports of MS110GMP).
Isolation (For MS106LP/MS106P/MS110GMP)
O: All the ports transmit data with the same priority.
On: The specic ports transmit data with a higher priority than other ports.
Priority (Only for MS110GMP)
The images in this guide are for demonstration only and may differ from your actual product.
© 2025 MERCUSYS 7100000115 REV1.2.1
MS106LP/MS106P: MS110GMP:
Power
On: The power is on
O: The power is o
PoE Status
On: Providing PoE power
Flashing: PoE fault
O: Not providing PoE power
PoE Max
On: 104 W≤Total power supply < 111 W
Flashing: Total power supply ≥ 111 W
O: Total power supply < 104 W
DC P er Adapterow
AC Power Cord

Mercusys hereby declares that the device is in compliance with the essential
requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU,
2011/65/EU and (EU)2015/863.
The original EU declaration of conformity may be found at
https://www.mercusys.com/en/ce/
EU declaration of conformity
General Specications
Specications
IEEE 802.3i, IEEE 802.3u, IEEE 802.3x (for all models)
IEEE 802.3ab (only for MS110GMP)
CSMA/CD. 802.3af/at PD supported
MS106LP/MS106P:
6 10/100 Mbps RJ45 Ports Auto-Negotiation/Auto MDI/MDIX
PoE Ports: Port 1–4
MS110GMP:
10 1000 Mbps RJ45 Ports Auto-Negotiation/Auto MDI/MDIX
PoE Ports: Port 1–8
10BASE-T:2-pair UTP/STP (≤100m) of Cat. 3 or above
100BASE-TX:2-pair UTP/STP (≤100m) of Cat. 5 or above
1000BASE-T:4-pair UTP/STP (≤100m) of Cat. 5e or above (only
for MS110GMP)
MS106LP/MS106P:1.2 Gbps
MS110GMP: 20 Gbps
Store-and-Forward
Automatically learning, automatically aging
MS106LP: External Power Adapter
Input: 100-240 VAC, 50/60 Hz
Output: 53.5 VDC/0.81 A
MS106P: External Power Adapter
Input: 220-240 VAC, 50/60 Hz
Output: 53.5 VDC/1.31 A
MS110GMP: External Power Adapter
Input: 100-240 VAC, 50/60 Hz
Output: 54 VDC/2.22 A
MS106LP: 40 W (up to 30 W for each PoE port)
MS106P: 67 W (up to 30 W for each PoE port)
MS110GMP: 111 W (up to 30 W for each PoE port)
CE, RoHS
Safety Information
Keep the device away from water, re, humidity or hot environments.
Do not attempt to disassemble, repair, or modify the device. If you need service,
please contact us.
Place the device with its bottom surface downward.
Do not use damaged charger or USB cable to charge the device.
Do not use any other chargers than those recommended.
Adapter shall be installed near the equipment and shall be easily accessible.
The POE output cannot be used to charge lithium batteries or devices with lithium
batteries.
The socket-outlet shall be near the equipment and shall be easily accessible.
Plug the product into the wall outlets with earthing connection through the power
supply cord.
Frequently Asked Questions (FAQ)
The Power LED should be lit when the power system is working normally. If the Power
LED is not lit, please check as follows:
A1:
Make sure the AC power cord/power adapter is connected the switch with power
source properly.
A2:
Make sure the voltage of the power supply meets the requirements of the input
voltage of the switch.
A3:
Make sure the power source is on.
Q1. Why is the Power LED not lit?
It is recommended that you check the following items:
A1:
Make sure that the cable connectors are rmly plugged into the switch and the
device.
A2:
Make sure the connected device is turned on and working well.
A3:
The cable must be less than 100 meters long (328 feet). If Extend Mode is enabled,
it should be less than 250 meters (820 feet).
Q2. Why is the Link/Act LED not lit when a device is
connected to the corresponding port?
A:
When the total power consumption of connected PoE devices exceeds the maximum,
the PoE port with a smaller port number has a higher priority. The system will cut o
power to the ports with larger port numbers to ensure supplying to other ports.
Taking MS110GMP as an example, if port 1, 2, 3 and 5 are consuming 25 W respectively,
and an additional PoE device with 15 W is inserted to port 4, the system will cut o the
power of port 5 to compensate for the overload.
Q3. Why are PoE ports not supplying power for PoE devices?
A1:
Before upgrading a connected PoE powered device (PD), disable PoE Auto
Recovery to avoid the PD’s damage.
A2:
When a PD does not send data packets to the switch for a long period in certain
scenarios (e.g. an IPC in sleep mode), disable PoE Auto Recovery to avoid the PD
repeatedly rebooting.
Q4. What should I notice before using the PoE Auto Recovery
feature?
Mercusys hereby declares that the device is in compliance with the essential
requirements and other relevant provisions of the Electromagnetic Compatibility
Regulations 2016 and Electrical Equipment (Safety) Regulations 2016.
The original UK declaration of conformity may be found at
https://www.mercusys.com/support/ukca/
UK declaration of conformity
For technical support, replacement services, user guides, and other
information, please visit https://www.mercusys com/support/..
Standard
Network Media (Cable)
Interface
Switching Capacity
Protocol
Power Supply
Forwarding Method
MAC Address Learning
PoE Budget
Certication
For MS110GMP only:
Environmental and Physical Specications
CE, RoHS
MS106LP: 0˚C to 40˚C (32˚F to 104˚F)
MS106P: -20˚C to 40˚C (-4˚F to 104˚F)
MS110GMP: -10˚C to 40˚C (14˚F to 104˚F)
-40˚C to 70˚C (-40˚F to 158˚F)
10% to 90% non-condensing
5% to 90% non-condensing
Certication
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Produkt Specifikationer
Mærke: | Mercusys |
Kategori: | Ikke kategoriseret |
Model: | MS110GMP |
Har du brug for hjælp?
Hvis du har brug for hjælp til Mercusys MS110GMP stil et spørgsmål nedenfor, og andre brugere vil svare dig
Ikke kategoriseret Mercusys Manualer

4 Juni 2025

4 Juni 2025

3 Juni 2025

3 Juni 2025

3 Juni 2025

3 Januar 2025

24 December 2024

23 December 2024

3 September 2024

2 September 2024
Ikke kategoriseret Manualer
- Ikke kategoriseret Robus
- Ikke kategoriseret Macally
- Ikke kategoriseret Beper
- Ikke kategoriseret Holzmann
- Ikke kategoriseret Pancontrol
- Ikke kategoriseret SteelBody
- Ikke kategoriseret Dreame
- Ikke kategoriseret Muama
- Ikke kategoriseret MyPhone
- Ikke kategoriseret Aicon
- Ikke kategoriseret Metapace
- Ikke kategoriseret Formuler
- Ikke kategoriseret SKLZ
- Ikke kategoriseret Ronco
- Ikke kategoriseret Genelec
Nyeste Ikke kategoriseret Manualer

6 Juni 2025

6 Juni 2025

6 Juni 2025

6 Juni 2025

6 Juni 2025

6 Juni 2025

6 Juni 2025

6 Juni 2025

6 Juni 2025

6 Juni 2025