Metro C533-CLFC-L Manual


Læs gratis den danske manual til Metro C533-CLFC-L (32 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 4 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 2.5 anmeldelser. Har du et spørgsmål om Metro C533-CLFC-L, eller vil du spørge andre brugere om produktet?

Side 1/32
INSTRUCTIONS FOR USE
C5 3 SERIES - 1 SERIES
HOLDING & PROOFING CABINETS
TABLE OF CONTENTS
SECTION PAGE
I. Basic Operating Guidelines .....Inside Front Cover
II. Safety Information .............................................. 3
III. Identifying Your Cabinet .................................... 4
IV. Installation & Set-up ........................................... 5
V. Product Features ............................................... 9
VI. Operating Instructions .......................................10
VII. Care & Maintenance .......................................... 12
VIII. Basic Troubleshooting ....................................... 13
IX. Service & Replacement Parts ............................ 15
X. Warranty .............................................................28
3 Series
1 Series
Metro Heated Cabinets are for
Hot Food Holding applications only.
DESCRIPTION
This manual covers cabinets with electrical ratings of: 120V-60 Hz-2000W, 120V-60 Hz-1440W,
220-240V, 50/60 Hz, 1681 – 2000W and 220-240V, 50/60 Hz, 1210 – 1440W
C5 1-3 SERIES HOLDING & PROOFING CABINETS — INSTRUCTIONS FOR USE
2
www.metro.com
L01-430
REV W 01/22
BASIC CABINET SETUP
A. Refer to DATA PLATE for electrical requirements. Cabinets rated at 120V 1440W must be
plugged into either a 15 amp or 20 amp 125VAC receptacle. Cabinets rated at 120V 2000W
must be plugged into a 20 amp 125VAC receptacle and used on an individual branch circuit.
Cabinets rated at 220-240V must be plugged into a 15 amp 250VAC receptacle.
B. With POWER switch OFF, plug into VAC grounded receptacle.
C. Fill stainless water pan to top with clean HOT tap water for Proofing, Combination, and Moisture
holding modules. Check water level every 3 hours (2 hours when Proofing) and refill with clean
HOT tap water as necessary.
HOLDING INSTRUCTIONS (Holding, Combo, Moisture Holding)
1) Set Combination Module switch to HOLD.
2) Set POWER switch to the ON position.
3) Set TEMPERATURE control to 10.
4) Moisture Module Only: Set MOISTURE control to 10 (or desired level).
5) Pre-heat cabinet until desired temperature is reached (typical heat-up time from 72°(22°C)
ambient to 160°(71°C)is approximately 45 minutes).
6) Re-set TEMPERATURE control and adjust as necessary to reach desired
temperature - setting 6-8 is typical for 150°(66°C) to 160° (71°C). Indicator light will turn on and
off as the heat thermostat cycles.
PROOFING INSTRUCTIONS (Combo and Proong)
1) Set Combination Module switch to PROOF.
2) Set POWER switch to the ON position.
3) Set TEMPERATURE control to 2.
4) Set MOISTURE control to 10.
5) Pre-heat cabinet until desired temperature and humidity is reached (typical heat-up time from
72°(22°C)ambient to 95°(35°C)and 95% relative humidity is approximately 30 minutes).
6) Adjust settings as necessary to reach desired temperature and humidity levels. Power indicator
lights will turn on and off as the heat and moisture thermostats cycle.
3 & 1 SERIES


Produkt Specifikationer

Mærke: Metro
Kategori: Ikke kategoriseret
Model: C533-CLFC-L

Har du brug for hjælp?

Hvis du har brug for hjælp til Metro C533-CLFC-L stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Metro Manualer

Metro

Metro C533-CLFC-L Manual

24 September 2025
Metro

Metro C539-HLDC-L Manual

24 September 2025
Metro

Metro C539-HDC-L Manual

24 September 2025
Metro

Metro C548X-ASFS-U Manual

23 September 2025
Metro

Metro C533-CLFC-U Manual

23 September 2025
Metro

Metro C537-HLFC-U Manual

23 September 2025
Metro

Metro C515-CFC-L Manual

23 September 2025
Metro

Metro C533-HLFS-L Manual

23 September 2025
Metro

Metro C545-ASFS-U Manual

23 September 2025
Metro

Metro C539-HFC-L Manual

23 September 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

IVT

IVT DSW-2000 Manual

24 September 2025
Duronic

Duronic DM354 Manual

24 September 2025
Lincoln Electric

Lincoln Electric NA-3 Manual

24 September 2025
Duronic

Duronic DM453VX1 Manual

24 September 2025
HABAU

HABAU Kanada Manual

24 September 2025
Prebena

Prebena 4C-WS38 Manual

24 September 2025
Draper

Draper 24807 Manual

24 September 2025
Celly

Celly TCSCREEN2C1A45W Manual

24 September 2025
T'nB

T'nB CHCARW1V2 Manual

24 September 2025
Prebena

Prebena 1GP-ALK35 Manual

24 September 2025