Læs gratis den danske manual til Middle Atlantic ICOMP-COOL-3 (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 8 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 4.5 anmeldelser. Har du et spørgsmål om Middle Atlantic ICOMP-COOL-3, eller vil du spørge andre brugere om produktet?

Side 1/4
I-00245 Rev B
ICOMP-COOL
Quiet-Cool Series Component Cooler
Instruction Sheet
m i d d l e a t l a n t i c . c o m
7.5VDC @ 70MA
m i d d l e a t l a n t i c . c o m
7.5VDC @ 70MA
TM
THANK YOU
Thank you for purchasing the Quiet-Cool Series ICOMP-COOL Component Cooler.
PRODUCT FEATURES
- Extends equipment life.
- Removes heat directly from the source.
- Up to ten individual ICOMP-COOLs can
be run from one power supply.
3-1/8
[79 mm]
3-3/16
[81 mm]
5/8 [16 mm]
SPECIFICATIONS
MODEL
POWER
REQUIREMENTS
CFM dBA @ 1 METER
ICOMP-COOL 7.5 VDC @ 70mA
8
Per Fan
19
ICOMP-COOL-E 7.5 VDC @ 70mA
8
Per Fan
ICOMP-COOL-3
7.5 VDC @ 210mA
8
Per Fan
19
24
- Fan turns on at 87ºF [30.5ºC] and turns off at 85ºF [29.4ºC]
- LED illuminates green when fan activates, and
red when fan deactivates
LED
Page 2
middl ea t lan tic
.co m
7.5VDC@ 70MA
m
id
dl ea tla
nt
ic .
c
om
7.5VDC @
70MA
PARTS
FAN UNIT
QTY
- ICOMP-COOL 1
- ICOMP-COOL - 3 3
- ICOMP-COOL - E 0
ADHESIVE BACKED FEET
QTY
- ICOMP-COOL 8
- ICOMP-COOL - 3 24
- ICOMP-COOL - E 8
WIRE TIE MOUNT
- ICOMP-COOL 5
- ICOMP-COOL - 3 15
- ICOMP-COOL - E 5
QTY
POWER SUPPLY
QTY
- ICOMP-COOL 1
- ICOMP-COOL - 3 1
- ICOMP-COOL - E 0
WIRE TIE
- ICOMP-COOL 5
- ICOMP-COOL - 3 15
- ICOMP-COOL - E 5
QTY
JUMPER CORD
- ICOMP-COOL 0
- ICOMP-COOL - 3 2
- ICOMP-COOL - E 1
QTY
1) Locate the hot spot on your component. (FIGURE A)
2) Clean area with provided alcohol wipe.
3) Remove paper covering adhesive ring. (FIGURE B)
4) Position ICOMP-COOL with power jack facing rear of component.
(FIGURE C) Press down to adhere.
TIP: If your cabinet does not have doors or sides, you may prefer to
position the unit so the air flows in a different direction.
5) Select appropriate wall plug for your region and install in provided
power supply.
6) Connect ICOMP-COOL to power source using provided Power
Supply.
NOTE: Wire Ties and Wire Tie Mounts are provided for cable
management.