1. Determine hole positions according  to left and right 
    side of the installation plate. The hole center is obtained 
    by measuring the distance as shown in the diagram above. 
 2. Dirll the piping plate hole with  65mm hole-core drill.
3. Drill the piping hole at either the right or the left and the 
    hole should be slightly slanted to the outdoor side.
4. Always take steps to protect the pipe when drilling metal 
    grid,metal plate or the like.
INSTALLATION MANUAL FOR 
ROOM AIR CONDITIONER
(Split Wall-Mounted Type)
DRILL A HOLE IN THE WALL 
INSTALLATION PLATE MOUNTING 
2 
1
 
I
N
D
O
O
R 
U
N
I
T 
          Please read these safety precautions carefully before installation
               Be sure to follow all the precautions below, they are all important for ensuring safety.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
1)  This equipment must be grounded and installed with ground leakage current breaker. It may cause 
electrical shock if grounding is not perfect.                             
2)  Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and 
      accumulates at surrounding of the unit, it may cause fire.
3)  Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water 
       may enter the room and damage the furniture.
1)  Install according to this installation instructions strictly. If installation is defective, it will cause water
leakage, electrical shock,or fire.
                 
2) Use the included accessories parts and specified parts for installation. otherwise, it will cause the set 
 to fall, water leakage, electrical shock,or fire.
                              
3)  Install at a strong and firm location which is able to withstand the set s weight. If the strength is not 
enough or installation is not properly done, the set will drop and cause injury.
                                                        
4)  For electrical work, follow the local national wiring standard, regulation and this installation instructions. 
An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or
                                                                         
                   defect found in electrical work, it will cause electrical shock,or fire.
                                            
5)  Use the specified cable and connect tightly and clamp the cable so that no external force will be acted 
on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
                                                                            
6)  Wiring routing must be properly arranged so that control board cover is fixed properly. If control board
 cover is not fixed perfectly, it will overheat at connection point of terminal, fire or electrical shock.
                                                        
7)  When carrying out piping connection, take care not to let air substances other than the specified 
 refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity,abnormal high pressure
                                                            
           in the refrigeration cycle, explosion and injury.
                             
8)  Do not modify the length of the power supply cord or use of extension cord, and do not share the 
single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock.
                                                        
SAFETY PRECAUTIONS
CAUTION
WARNING
CAUTION
WARNING
      Please read this installation manual carefully before operating the unit to ensure correct installation.
      If the power cord is damaged, replacement work shall be performed by authorised personnel only.
      Installation work must be performed in accordance with the national wiring standards by authorised 
      personnel only. 
      Contact an authorized service technician for repair, maintenance and installation of this unit.
      This appliance is not intended for use by persons(including children) with reduced physical, sensory
     or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
     or instruction concerning use of the appliance by persons responsible for their safety. 
     Children should be supervised to ensure that they do not play with the appliance.
     All the pictures in the instructions are for explanation purposes only. The actual shape should prevail.
     The design and specifications are subject to change without prior notice for product improvement. 
     Consult with the sales agency or manufacturer for details. 
   
There should not be any heat source or stream 
near the unit.
There should not be any obstacles blocking the 
air circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into 
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the 
wall,ceiling,fence or other obstacles.
There should not be any direct sunlight. If unavoidable, 
sunlight prevention should be taken into consideration.
Outdoor unit dimension
          mm(WxHxD)
 A(mm) B(mm)
530 290
560
549
640
335
325
404
481
549
276
276
Mounting dimensions
670x540x265
780x540x250
760x590x285
845x700x320
810x558x310
940x810x375
Indoor  unit
Outdoor  unit
If an awning is built over the unit to prevent 
direct sunsight or rain,be careful that heat 
radiation from the condenser is not obstructed.
There should not be any animal or plant which 
could be affected by hot air discharged.
Keep the spaces indicated by arrow from wall 
ceiling, fence or other obstacles.
Do not place any obstacles which may cause 
a short circuit of the discharged air.
 Anchor the outdoor unit with a bolt and nut   10 or 
8 tightly and horizontally on a concrete or rigid mount.
Settlement of outdoor unit
NOTE: The outdoor unit you purchase may be like one
of the following. Install the outdoor unit according to the
dimension as indicated in the table below:
A
W
B
D
Air inlet 
Air outlet
Air inlet 
INSTALLATION PRECAUTIONS
CONNECT THE CABLE TO THE INDOOR UNIT
3 
,
Terminal block of indoor unit
Connect the cable to the indoor unit
                  Before performing any electrical work, turn off the main power to the system.
1. The inside and outside connecting cable can be connected without removing the front grille.
2. The indoor power cord type is H05VV-F or H05V2V2-F, the outdoor power cord and 
    interconnected cord type is H07RN-F.
3. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw.
4. Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor s
    respectively.
5. Wrap those cables not connected with terminals with insulation tapes, so that they will not touch
    any electrical components. Secure the cable onto the control board with the cord clamp.
    
NOTE:
Electronic box
cover
Front Panel
To outdoor unit
 Model A Model B
To outdoor unit
L(1)
2(N)
S
1
W
2(N)
S
1(L)
1
2
3
4
5
7
8
9
10
6
Installation Plate
Clip Anchor
Self-tapping Screw A ST3.9x25 
Seal(For cooling & heating models only)
 Drain Joint(For cooling & heating models only       
Connecting 
pipe 
Assembly
Liquid side 
Gas side
Remote controller 
Self-tapping Screw B ST2.9x10 
6.35
9.52
9.52
12.7
 16 
Parts you must purchase. The pipe 
size differ from appliance to appliance. 
Consult the technician for the proper 
size.
1
5-8(depending on models)
5-8(depending on models)
1
1
1
2
1
1
Except the above parts provided,the other parts needed during installation you must 
purchase.
Remote controller holder
ACCESSORIES
Number
Name of Accessories Qty 
NOTE:
optional 
parts
SELECT THE BEST LOCATION
NOTE: If used as MONO unit, for the standby control needs, the cross section area of cable connected 
to  L(1)/W, 1/1(L),  2(N) must be sufficient for the maximum system current. The maximum system current 
is equal to the sum of indoor unit and outdoor unit rated current. If used as MULTI unit,  L(1)/W on the 
terminal block does not need to be connected.
4 
CONNECTIVE PIPE AND DRAINAGE INSTALLATION 
1. Run the drain hose sloping downward. 
    Do not install the drain hose as illustrated 
    in wrong figures.
2. When connecting extension drain hose, 
    insulate the connecting part of extension  
    drain hose with a shield pipe, do not let 
    the drain hose slack.
Drainage
Right Wrong
Correct orientation 
of Installation Plate
1. Fit the installation plate horizontally on 
    structural parts of the wall withspaces 
    around the installation plate.
2. If the wall is made of brick, concrete 
    or the like, drill five or eight 5mm 
    diameter holes in the wall. Insert 
    clip anchor for appropriate mounting 
    screws.
3. Fit the installation plate on the wall 
    with five or eight type A screws.
Mount the Installation Plate and drill 
holes in the wall according to the wall 
structure and corresponding mounting 
points on the installation plate. The 
installation plate providedwith the 
machine differ from appliance
to appliance.(Dimensions are in
  mm   unless otherwise stated)
NOTE:
NOTE:
" 
" 
Installation Plate Mounting
The mounting wall is strong and solid enough
 to prevent it from the vibration. 
45
45
280
120mm or 
more to wall
120mm or 
more to wall
120mm or 
more to wall
150mm or more to ceiling
150mm or more to ceiling
Left rear side 
refrigerant
 pipe hole  65
36.5
835
140 110
Left rear side 
refrigerant
 pipe hole  65
Right rear side 
refrigerant
 pipe hole  65
Right rear side 
refrigerant
 pipe hole  65
Indoor unit outline
Indoor unit outline
120mm or 
more to wall 120mm or 
more to wall
Indoor unit outline
990
315
135
260
150mm or more to ceiling
Left rear side 
refrigerant
 pipe hole  65 Right rear side 
refrigerant pipe 
hole  65
Model C
Model B
Model A
120mm or 
more to wall
45
45
36.5
750
180 110
280
  202000192486    CS159I1-BP11M(L)    20140515
Air freshening filter(used to install on Air filter)
Electric safety regulations for the initial Installation
1. If there is serious safety problem about the power supply, the technicians should refuse to install 
     the air conditioner and explain to the client until the problem is solved. 
2. Power voltage should be in the range of 90%~110%of rated voltage.
3. The  surge protector and main power switch with a 1.5 times capacity of Max. Current of the unit should 
      be installed in power circuit. Ensure the air conditioner is grounded well.
4. The appliance shall be installed in accordance with national wiring regulations. Do not operate your air 
     conditioner in a wet room such as a bathroom or laundry room.
5. An all-pole disconnection device which has at least 3mm clearances in all poles, and have a leakage 
     current that may exceed 10mA, the residual current device(RCD) having a rated residual operating 
     current not exceeding 30mA, and disconnection must be incorporated in the fixed wiring in accordance 
     with the wiring rules.
6. For the unit adopts auxiliary electric heater, keep at least 1 meter away  from the nearest combustible
     materials. 
7. According to the attached Electrical Connection Diagram  located on the panel of the indoor & outdoor 
     unit to connect the wire.
8. All wiring must comply with local and national electrical codes and be installed by qualified and 
    skilled electricians. 
9. An individual branch circuit and single receptacle used only for this air conditioner must be 
   available. See the following table for suggested wire sizes and fuse specifications:
Minimum cross-sectional area of conductors: 
Rated curr ent 
of appliance
(A)
 >3  and   6
 >6  and   10
 >10  and   16
 >16  and   25
 >25  and   32
 >32  and   40
Nominal cross-sectional 
area
(mm2)
0.75
1
1.5
2.5
4
6
Electrical work
The wire size of power supply cord and 
interconnected wire and the current of 
the fuse or switch are determined by the 
maximum current indicated on the 
nameplate which located on the side 
panel of the unit. Please refer to the 
nameplate before selecting the wire size, 
fuse or switch.
  
The controller of the air conditioner 
designed with a fuse protection function 
under abnormal conditions, the 
specifications of the fuse have printed on 
the circuit board, such as: T3.15A/250VAC, 
T5A/250VAC, etc.
NOTE: