Optex SIP-4010WF Manual

Optex Detektor SIP-4010WF

Læs gratis den danske manual til Optex SIP-4010WF (11 sider) i kategorien Detektor. Denne vejledning er vurderet som hjælpsom af 29 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 15 anmeldelser. Har du et spørgsmål om Optex SIP-4010WF, eller vil du spørge andre brugere om produktet?

Side 1/11
- 1 -
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
2.3-4.0 m
(7.6-13 ft.)
INSTALLATION AND MAINTENANCE NOTES
Warning Caution
Never repair or
modify product
Hold the main unit
securely when you
install or service it.
If you remove your
hands from the main
unit when cables are
connected to it, the
main unit may fall
and the connector
cables may break
or the circuit board
may be damaged.
Caution
Verify that the
power is off before
connecting the
wiring.
2
PARTS IDENTIFICATION
1
NO.59-1576-1 0905-30
INSTALLATION INSTRUCTIONS
Synthesized Intelligent PIR
REDWALL-V series
Synthesized Intelligent PIR
REDWALL-V series
FEATURES
* Lowpowerconsumption(3-9VDC,40μA(standby)5mAmax.)
* Low battery signal
* Intelligent PIR Detection System
- Three dual pyro-elements with patented Double Conductive
Shielding
- Detection of ambient temperature and illuminance for
automatic sensitivity management
- Advanced detection algorithm
* Anti-vandalism functions
- Max.4m(13ft.)installationheight
- Anti-rotation function with accelerometer
- Anti-masking function with photo-beam
* Independent sensitivity selector for near/far areas
* Detection logic selector
* Detection range selector
* Independent N.C. and N.O. ALARM output
* Adjustable alarm interval time
* Reinforced polycarbonate housing
REDWALL-V
: Low current Synthesized Intelligent PIR
SIP-3020WF
SIP-4010WF
SIP-404WF
Mountthedetectorsothatthemajorityoftrafcowisacrossthedetectionpattern.
*1: Not used for the SIP-4010WF and
SIP-404WF.
2-1
INSTALLATION HINTS
Base
Fixingscrew
for the base
Main unit
Masking plate for near
area (*1)
Fixingrubber
form (*1)
Window
Fixingscrew
for the cover
Cover
Far area mirror
Masking plate for far area
Fixingrubberform
Adjustment screws
(two facing each other)
Angle adjustment guide
Near area mirror
Arrow marking
Fixingscrew
Nylon wire
loop
When servicing, the sensor
can be hooked onto the
base using the nylon wire
loop.
- 2 -
3-1
Wall Mounting
Attach the paper template (an accessory) onto the wall,
and drill a 6-mm dia. mounting hole and a cabling hole.
Insert the anchor bolt (an accessory) into the board mount
hole.
Using an allen key, remove the main unit from the base.
Drill through the bushing of the wiring hole, pass the cable
through the hole, and secure the base to the wall.
Connect the cable to the terminal block (see Step 3-3).
Mount the main unit onto the base.
Cautions>>
When mounting the main unit, take care not to trap the
nylon wire loop. Also, take care not to get your fingers
caught.
Check to see that the various settings and operations are
correct.
Caution>>
When the red LED flashes after the power turns on,
this signifies that the system is warming up. Wait for
approximately 120 seconds.
INSTALLATION AND ANGLE ADJUSTMENT
3
(1)
(2)
(3)
(4)
(5)
(6)
3-2
Inside View of the Base
3-3
WIRING
Cautions>>
Maximum wiring length is 3 m.
Name Function
TROUBLE
OUTPUT
Trouble out is used for anti-masking signal and
low battery signal. When an object is placed close
to the lens surface, for a period of more than
120 seconds (approx.), the IR anti-masking circuit
will activate and generate a trouble signal.
When the battery power is less than 2.3V DC, and
this condition continues more than 2.5 hours, the
signal will be generated.
TAMPER
OUTPUT
It is detected when the cover is opened.
It is detected when the main unit is removed from
its base.
Anti-Rotation:
Damage sustained by the main unit is detected.
If the main unit is impacted in a horizontal or
vertical direction and if the position of the main
unit has changed, damage sustained by the main
unit will be detected.
Waterproof seal
(Do not remove
this seal.)
Base
Bushing of wiring
hole
Open wiring cap
Main unit connector
Wall mounting hole
Wall mounting hole
Bushing of wiring
hole
Wiring terminals
1 Loosen the
xing screw
for the
base.
2 Open.
3 Unplug
the cable
connector.
4 Pull out.
POWER INPUT
TAMPER OUTPUT *1
ALARM OUTPUT (N.C.)
ALARM OUTPUT (N.O.)
TROUBLE
OUTPUT
SPARE
4 Tighten and
secure the
xing screw
for the base.
2 Connect the
connector.
3 Close.
1 Insert and
secure here.
Nylon
wire
loop
Distance from the ground to
the bottom of the template
must be between 2.3 m (7.6 ft.)
and 4 m (13 ft.).
WF-100DT
(Transmitter)
+ (red)
– (black)
DC POWER SUPPLY (BATTERY)
ELECTRICAL CONNECTIONS TO TRANSMITTER
* The Cable Gland (accessory )
enables wiring.
*1: TAMPER terminals to be connected to a 24 hour supervisory loop.


Produkt Specifikationer

Mærke: Optex
Kategori: Detektor
Model: SIP-4010WF

Har du brug for hjælp?

Hvis du har brug for hjælp til Optex SIP-4010WF stil et spørgsmål nedenfor, og andre brugere vil svare dig




Detektor Optex Manualer

Optex

Optex SIP-5 Manual

21 December 2024
Optex

Optex FLX-P-ST Manual

28 August 2024
Optex

Optex FLX-P-DT Manual

27 August 2024
Optex

Optex FX-360 Manual

10 August 2024
Optex

Optex FlipX Manual

5 August 2024
Optex

Optex RXC-ST Manual

4 December 2023
Optex

Optex OVS-01GT Manual

26 Marts 2023

Detektor Manualer

Nyeste Detektor Manualer