The detection zones of Redwall-V, which may be cause of false
alarms can be eliminated by masking.
1. To confirm detection zones
Use optional Area View Finder, AVF-1
2. To eliminate unnecessary detection zones
a. Use supplied area masking seals.
b. Use equiped area masking plates.
The following shows an example;
Detection zones and related segments of the mirror of SIP-3020.
See step 4-1 and 6.
INSTALLATION AND MAINTENANCE NOTES
Warning
Failure to follow the instructions provided
with this indication and improper handling
may cause death or serious injury.
Caution
Failure to follow the instructions provided
with this indication and improper handling
may cause injury and/or property damage.
The check mark indicates recommendation.
The nix sign indicates prohibition.
Warning Caution
Never repair or
modify product
Hold the main unit
securely when you
install or service it.
If you remove your
hands from the main
unit when cables are
connected to it, the
main unit may fall
and the connector
cables may break
or the circuit board
may be damaged.
Caution
Verify that the
power is off before
connecting the
wiring.
2
PARTS IDENTIFICATION
1
No. 59-1564-6 1710-11
No. 59-1564-6 1710-11
INSTALLATION INSTRUCTIONS
Synthesized Intelligent PIR
REDWALL-V series
Synthesized Intelligent PIR
REDWALL-V series
FEATURES
* Intelligent PIR Detection System
- Detection of ambient temperature and illuminance for
automatic sensitivity management
- Advanced detection algorithm
- Three dual pyro-elements with patented Double Conductive
Shielding for main area
)stnemele-oryp laud elbuoD( rotceted enoz peerc ni-tliuB *
* Anti-vandalism functions
- Anti-rotation function with accelerometer
- Anti-masking function with photo-beam
- Reinforced polycarbonate housing
- Max. 4m (13ft.) installation height
* Independent sensitivity selector for creep/near/far areas
* Detection logic selector
* Detection range selector
* Independent N.C. and N.O. outputs
* Adjustable alarm interval time
REDWALL-V
: Synthesized Intelligent PIR with creep zone
SIP-3020/5
SIP-4010/5
SIP-404/5
*1: Not used for the SIP-4010/5 and SIP-404/5.
2-1
INSTALLATION HINTS
2.3-4.0 m
(7.6-13 ft.)
F
6 4 2 5 3 1
F 6 F 4 F 2 F 5 F 3 F 1
E 6 E 4 E 2 E 5 E 3 E 1
D 6 D 4 D 2 D 5 D 3 D 1
C 6 C 4 C 2 C 5 C 3 C 1
B 6 B 4 B 2 B 5 B 3 B 1
E
D
C
B
Area Masking Seals
3020 (
1 2
3
4 5 6 7
B1
C1
D1
E1
F1 F6
2F 3F 4F 5F
E5E2 E3 E4
D5D2
C5C2 C3 C4
B5B2 B4
3D 4D
B3
E6
D6
C6
B6
Area View Finder
FAR
NEAR
7
65
43
2
1
B6
C6
D6
E6
B3
C3
D3
E3
F3
B2
C2
D2
E2
F2
B1
C1
D1
E1
F1
B4
C4
D4
E4
F4
B5
C5
D5
E5
F6
F5
Mount the detector so that the majority of
traffic flow is across the detection pattern.
REDWALL-V SIP-3020
Base
Fixing screw
for the base
Main unit
Masking plate for near
area (*1)
Window
Fixing screw
for the cover
Cover
Far area mirror
Masking plate for far area
Fixing rubber form
Adjustment screws
(two facing each other)
Angle adjustment guide
Near area mirror
Arrow marking
Fixing screw
Nylon wire
loop
When servicing, the sensor
can be hooked onto the base
using the nylon wire loop.
Creep unit Fixing rubber
form (*1)
* UL-1: SIP-3020/5, -4010/5 and -404/5 are recommended not to be connected to an
alarm initiating circuit but may be connected to a trouble alarm circuit if nuisance trips
are not tolerable.
UL
* UL/c-UL Listed
* SIP-4010/5 and SIP-404/5 do not
have a masking function.
* Creep
zones can
not be
masked.
- 2 -
3-1
Wall Mounting
Attach the paper template (an accessory) onto the wall,
and drill a 6-mm dia. mounting hole and a cabling hole.
Insert the anchor bolt (an accessory) into the board mount
hole.
Using an allen key, remove the main unit from the base.
Drill through the bushing of the wiring hole, pass the cable
through the hole, and secure the base to the wall.
Connect the cable to the terminal block (see Step 3-3).
Mount the main unit onto the base.
Cautions>>
When mounting the main unit, take care not to trap the
nylon wire loop. Also, take care not to get your fingers
caught.
Check to see that the various settings and operations are
correct.
Caution>>
When the red LED flashes after the power turns on,
this signifies that the system is warming up Wait for .
approximately 60 seconds.
INSTALLATION AND ANGLE ADJUSTMENT
3
(1)
(2)
(3)
(4)
(5)
(6)
3-2
Inside View of the Base
3-3
WIRING
*1: TAMPER terminals to be connected to a 24 hour supervisory loop.
TROUBLE
OUTPUT
Trouble out is used for anti-masking signal. When
an object is placed close to the lens surface, for
a period of more than 100 seconds (approx.), the
IR anti-masking circuit will activate and generate a
trouble signal.
TAMPER
OUTPUT
It is detected when the cover is opened.
It is detected when the main unit is removed from
its base.
Anti-Rotation:
Damage sustained by the main unit is detected.
If the main unit is impacted in a horizontal or
vertical direction and if the position of the main
unit has changed, damage sustained by the main
unit will be detected.
Waterproof seal
(Do not remove
this seal.)
Base
Bushing of wiring
hole ( 18)Φ
Open wiring cap
Main unit connector
Wall mounting hole
Wall mounting hole
Bushing of wiring
hole ( 18)Φ
Wiring terminals
1 Loosen the
fixing screw
for the
base.
2 Open.
3 Unplug
the cable
connector.
4 Pull out.
POWER INPUT
TAMPER OUTPUT *1
ALARM OUTPUT (N.C.)
ALARM OUTPUT (N.O.)
TROUBLE OUTPUT
SPARE
4 Tighten and secure
the fixing screw for
the base.
2 Connect the
connector.
3 Close.
1 Insert and
secure here.
Nylon
wire
loop
Distance from the ground to
the bottom of the template
must be between 2.3 m (7.6 ft.)
and 4 m (13 ft.).
CREEP
ALARM OUTPUT (N.C.)
ALARM OUTPUT (N.O.)
Unit:mm
Wiring hole (M20 x 1.5)
* UL-2: All relay outputs of Alarm/Trouble are resistive load only.
* UL-3: UL requires that the detector is to be connected to a UL listed Burglar power
supply Class 2, capable of providing a input range of not greater than 11 VDC - 26
VDC, 50 mA and battery standby time of 4 hours.
* UL-4: The equipment shall be installed in accordance with the National Electrical
Code, NFPA 70.
Name Function


Produkt Specifikationer

Mærke: Optex
Kategori: Detektor
Model: SIP-5

Har du brug for hjælp?

Hvis du har brug for hjælp til Optex SIP-5 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Detektor Optex Manualer

Optex

Optex SIP-5 Manual

21 December 2024
Optex

Optex FLX-P-ST Manual

28 August 2024
Optex

Optex FLX-P-DT Manual

27 August 2024
Optex

Optex FX-360 Manual

10 August 2024
Optex

Optex FlipX Manual

5 August 2024
Optex

Optex RXC-ST Manual

4 December 2023
Optex

Optex OVS-01GT Manual

26 Marts 2023

Detektor Manualer

Nyeste Detektor Manualer