Læs gratis den danske manual til PCE Instruments PCE-BPD-C-66D (30 sider) i kategorien Måling. Denne vejledning er vurderet som hjælpsom af 20 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 10.5 anmeldelser. Har du et spørgsmål om PCE Instruments PCE-BPD-C-66D, eller vil du spørge andre brugere om produktet?

Side 1/30
Chronometers and me counters
Big panel displays with chronometer and me counter funcons. Dierent formats available with 60 mm
and 100 mm digit height, 4 and 6 digits, in red color. Sturdy metal housing, with full IP65 protecon,
designed for panel, wall or hanging mount. Versale and congurable, with up and down counng
modes, independent controls for ‘start, ‘stop’ and ‘resetsignals, reading in decimal and sexagesimal
formats (me format), congurable f
ast access menu, on power up’ funcon, password and 5 congu-
rable brightness levels
. Universal AC and DC power. Accepts up to 3 output and control opons (relays,
analog retransmission, Modbus RTU, transistor outputs, RS-485 ASCII, ...). Conguraon from frontal
keypad or remote keypad.
BIG PANEL DISPLAYS
5533r02
User’s Manual
PCE-BPD-C
www.pce-instruments.com
2
PCE Instruments
1. Large display PCE-BPD-C
Big panel displays with chronometer and me counter funcons
Big panel displays for long distance reading, for industrial ap-
plicaons. Dierent formats available with 4 and 6 digits, with
60 mm
and 100 m digit height. Front keypad to access the con-
guraon menu, and oponal remote keypad.
Mulple
reading me formats in hours, minutes, seconds,
cents of seconds and days. Congurable for decimal or sex-
agesimal reading (me format). Funcons for up and down
c
ounng, with preset value congurable.
Controls
Independent controls for ‘start, stop’ and ‘reset’ through free
potenal contacts. Congurable for acvaon with other con-
trol signals (NPN, PNP, inducve, ...).
R
eset
External reset control, with acvaon congurable by edge or
by level, front reset and automac reset congurable when
reaching an alarm setpoint.
Special funcons
Special funcons with acvaon by external connecon :
counng direcon, total accumulated mes, total exceeded
me, display hold, and memory of events, maximum and min-
imum (see secon 1.14.6).
Al
arms
Independent alarms congurable as maximum or minimum,
with congurable acvaon and deacvaon delays and op
-
onal inverted relay acvaon and relay manual unlocking.
Alarms
with ‘repeat’ mode with acvaon at mulples of con-
gured me (see secon 1.14.12).
On_alarm’ parameter to link funcons to alarm acvaon;;
1. Idenfy the instrument format (see secon 1.4)
2. Power and signal connecons
- open the instrument (see secon 1.5)
- connect the power (see secon 1.7)
- connect the signal (see secon 1.8)
- close the instrument (see secon 1.5)
3. Congure the instrument (see secon 1.14)
- select the reading format, counng direcon and preset
value (see secon 1.14.2)
4. Advanced conguraon (oponal)
- funcons ‘on power up’, external reset and ‘B’ funcon
(see secon 1.14.7)
- control conguraons (see secon 1.14.10)
- congure the alarms (see secon 1.14.12)
1.1 How to use this manual
If this is the rst me you are conguring big panel display,
below are the steps to follow to install and congure the in-
strument. Read all the manual secons in order to have a
full
and clear view of the characteriscs of the instrument.
Do not forget to read the installaon precauons at secon
1.20.
- congure the fast access (see secon 1.14.14), and key ‘LE’
(1.14.15)
- congure other funcons (see secon 1.14.16)
5. If the instrument includes analog output or serial commu-
nicaons
- to include an opon to an instrument see secon 1.6
- to congure an installed opon, access the opon congu
-
raon menu (see secon 1.14.23)
6. Install the instrument
- mount on panel, wall or hanging (see secon 1.19)
- adjust the brightness level according to your environmen
-
tal needs (see secon 1.14.22)
7. Check applicaon examples at secons 1.15 and 1.16
connue, reset to ‘0’, load ‘preset’ value or stop counng (see
secon 1.14.12).
Flash
Congurable display ashing in case of stop’ counng, start
counng, or alarm acvaon.
Security on start-up
‘On power-up’ funcon to dene inacvity mes aer power-
up, congure the counter status (‘start’ or ‘stop’) aer power-
up, and the opon to apply a reset aer power-up.
Memory
The instrument saves and recovers the last reading value in
case of power-loss.
Congurable ‘fast-access’ menu
The front key ‘UP’ () gives access to a user congurable menu
with direct access to several useful funcons such as alarm
setpoints and/or preset value (see secon 1.14.14).
Congurable Fast accessto selected funcons with key ‘UP
(5) (see secon 1.14.14), typically alarm setpoints and preset
values.
Control and retransmission opons
Output and control opons with 1, 2 and 3 relays, transistor
outputs, controls for SSR relays, isolated analog outputs, com
-
municaons in Modbus RTU, RS-485 ASCII and RS-232.
Mechanic
al and mounng
Sturdy metal housing with full IP65 protecon. Internal
connecons by plug-in screw clamp terminals, and output
through cable glands. Housing prepared for panel, wall and
hanging mount.