Læs gratis den danske manual til PCE Instruments PCE-DMM 20 (2 sider) i kategorien Måling. Denne vejledning er vurderet som hjælpsom af 11 personer og har en gennemsnitlig bedømmelse på 4.1 stjerner ud af 6 anmeldelser. Har du et spørgsmål om PCE Instruments PCE-DMM 20, eller vil du spørge andre brugere om produktet?

Side 1/2
User Manual
Pressure gauge PCE-DMM 20, PCE-DMM 21,
PCE-DMM 50, PCE-DMM 51
1.1 Information on the operating manual
This operating manual contains important information on
proper usage of the device. Read this operating manual
carefully before installing and starting up the pressure
measuring device.
Adhere to the safety notes and operating instructions which
are given in the operating manual. Additionally applicable
regulations regarding occupational safety, accident
prevention as well as national installation standards and
engineering rules must be complied with!
This operating manual is part of the device and must be
kept at a, for the personnel always accessible location,
close to the installation position of the device.
This operating manual is copyrighted. The contents of this
operating manual reect the version available at the time of
printing. It has been issued to our best knowledge and
belief. However, errors may have occurred. For incorrect
statements and their consequences, liability cannot be
assumed by PCE Instruments.
– – Technical modications reserved
1.2 Symbols used
DANGER! Dangerous situation, which may result in
serious or fatal injuries
WARNING! Potentially dangerous situation, which
may result in fatal or serious injuries
CAUTION! Potentially dangerous situation, which
may result in minor injuries
!CAUTION! Potentially dangerous situation, which
may result in damage of objects
NOTE Tips and information for the user to ensure
good conditions for the operation.
1.3 Target group
WARNING! To avoid hazards for the operator and
damages of the device, following described instructions
have to be worked out by qualied technical personnel.
1.4 Limitation of liability
No liability is assumed and warranty claims are excluded in
case of non-observance of the operating manual, improper
application, modication of or damage to the device.
1.5 Intended use
- The battery powered digital pressure gauge has been
exclusively designed for applications in hydraulics and
pneumatics as well as for mechanical engineering. It
can be easily and quickly installed in situ.
- It is in the responsibility of the user to verify whether the
chosen device is suitable for the intended application.
In case of any doubts, contact our technical department
to eliminate any indistinctness. PCE Instruments does
not assume any liability for an incorrect selection and
its consequences!
WARNING! Danger through improper usage!
1.6 Package contents
Please verify that all listed parts are undamaged included in
the delivery and check for consistency specied in your
order:
- digital pressure gauge
- mounting instructions
3. Mechanical installation
3.1 Mounting and safety instructions
WARNING! Install the device only when depressurized
and currentless!
WARNING! This device may only be installed by
qualied technical personnel who has read and
understood the operating manual!
!Handle this electronic precision measuring device
carefully in packed as well as in unpacked condition!
!The device must not be subject to any changes or
modications.
!The device may not be thrown!
!To avoid damaging the diaphragm, remove packaging
and protective cap only directly before starting up the
device A delivered protective cap must be stored! .
!Place the protective cap on the pressure port again
immediately after disassembling.
!Handle the unprotected diaphragm very carefully - it is
very sensitive and may be easily damaged.
!Do not use any force when installing the device to
prevent damage of the device and the plant!
!The display and the plastic housing are equipped with
rotational limiters. Please do only rotate the display or
the housing within the limit.
Take note that no inadmissibly high mechanical
stresses occur at the pressure port as a result of the
installation, since this may cause a shifting of the
characteristic curve or the demage.
In hydraulic systems, position the device in such a way
that the pressure port points upward (venting).
Provide a cooling line when using the device in steam
lines.
3.2 General installation steps
- Carefully remove the pressure measuring device from
the package and dispose of the package properly.
- Then go ahead as detailed in the specic instructions
below.
3.3 Installation steps for DIN 3852
DO NOT USE ANY ADDITIONAL SEALING MATERI-
ALS, LIKE YARN, HEMP OR TEFLON TAPE!
- Check to ensure the proper groove tting of the o-ring
and additionally to ensure no damage to the o-ring.
- Ensure that the sealing surface of the taking part is
perfectly smooth and clean. (RZ 3.2)
- Screw the device into the corresponding thread by
hand.
- If you have a device with a knurled ring, the transmitter
has to be screwed in by hand only.
- Devices with a spanner at have to be fully tightened
with an open-end Devices with a spanner at have to
be tightened with an open-end wrench (G1/4": approx.
5 Nm; G1/2": approx. 10 Nm; G3/4": approx. 15 Nm;
G1": approx. 20 Nm; G1 1/2": approx. 25 Nm).
-The indicated tightening torques must not be ex-
ceeded!
3.4 Installation steps for EN 837
- Use a suitable seal, corresponding to the medium and
the pressure input (e. g. a cooper gasket).
- Ensure that the sealing surface of the taking part is
perfectly smooth and clean. (RZ 6.3)
- Screw the device into the corresponding thread by
hand.
- Tighten it with a wrench (for G1/4": approx. 20 Nm; for
G1/2": approx. 50 Nm).
-The indicated tightening torques must not be ex-
ceeded!
3.5 Installation steps for NPT
- Use a suitable seal -strip). (e. g. a PTFE
- Screw the device into the corresponding thread by
hand.
- Tighten it with a wrench (for 1/4" NPT: approx. 30 Nm;
for 1/2" NPT: approx. 70 Nm).
-The indicated tightening torques must not be ex-
ceeded!
3.6 Installation steps for dairy pipe
- Check to ensure that the O-ring ts properly into the
intended groove in the mounting part.
- Center the dairy pipe connection in the counterpart.
- Screw the cup nut onto the mounting part.
- Then tighten it with a hook wrench.
3.7 Installation steps for Clamp and Varivent
- Use a suitable seal corresponding to the medium and
the pressure input.
- Put the seal onto the corresponding mounting part.
- Center the Clamp or Varivent connection on thetting
counterpart with seal.
- Then t the device with a suitable fastening element (e.
g. semi-ring or retractable ring clamp) according to the
supplier’s instructions.
3.8 Installation steps for connecting flanges
- Use a suitable seal corresponding to the medium and
pressure input. (e. g. a ber gasket).
- Put the seal between connecting ange and counter
ange.
- Install the device with 4 resp. 8 screws (depending on
ange version) on the counter ange.
3.9 module Positioning of the display
The display module of the pressure gauge is rotatable so
that clear readability is guaranteed even on unusual
installation positions.
4. Supply / changing the batteries
The digital pressure gauge is supplied by two 3.6 V-lithium-
batteries (Type 1/2 AA). Stored values/parameters are also
kept after changing the batteries.
If the symbol for low batteries is indicated in the display, it is
necessary to replace them as soon as possible with two
new ones of the same type in order to ensure a good
readability of the values. This has only to be done in
switched-o condition.
The battery case is located under the black, circular plastic
cap on the top of the housing.
To change the batteries go ahead
as follows:turn the plastic cap 45°
anti clockwise by a coin
(e. g. 2 € coin) as far as possible
- hold the count tight and lever
the plastic cap out of the
housing with help of the
count
- take the cap o and change
the batteries
- lock the device after that
properly
!An incorrect usage may cause a leak out of batteries
and so a damage the
device!
!Never combine batteries of dierent types or old with
new ones.
! Make sure that the batteries are connected correctly
with the corresponding contacts in the battery tray.
!Never try to charge batteries, demount them, or short-
circuit them.
!Keep the batteries away from heat and unshielded
ame.
!use only batteries with UL certication
5 Initial start-. up
WARNING! Before start-up, the user has to check for
proper installation and for any visible defects.
WARNING! The device can be started and operated by
authorized personnel only, who have read and under-
stood the operating manual!
WARNING! The device has to be used within the
technical specications, only (compare the data in the
data sheet)!
6. Placing out of service
WARNING! When dismantling the device, it must
always be done in the depressurized and currentless
condition! Check also if the medium has to be drained
off before dismantling!
WARNING! Depending on the medium, it may cause
danger for the user. Comply therefore with adequate
precautions for purication.
plastic cap above
battery case
Fig. 1 battery case
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Unit 11
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.co.uk
7. Operation
7 display elements .1 Operating and
Fig. 2 display LC
The indication of the measured value as well as the
conguration of the individual parameters occurs menu-
driven via the LC display. The individual functions can be
set with the help of three miniature push buttons located in
the front.
The menu system is a closed system allowing you to scroll
both forward and backward through the individual set-up
menus to navigate to the desired setting item. All settings
are permanently stored in an EEPROM and therefore
available again even after . a battery change
7.2 Structure of the menu system
8 Maintenance.
In principle, this device is maintenance-free. If desired, the
housing of the device can be cleaned when switched of
using non- cleaning solutions. a damp cloth and aggressive
With certain media, however, the diaphragm may be pollut-
ed or coated with deposit. It is recommended to dene
corresponding service intervals for control.. After placing the
device out of service correctly, the diaphragm can usually
be cleaned carefully with a non-aggressive cleaning solution
and a soft brush or sponge If the diaphragm is calcied, it is .
recommended to send the device to PCE Instruments for
decalcication Please read therefore the chapter Repair . “ ”
below.
!A false cleaning of the device can cause an irreparable
damage on the diaphragm. Therefore never use point-
ed objects or pressured air for cleaning the diaphragm.
9 Return.
Before every return of your device, whether for recalibration,
decalcication, modications or repair, it has to be cleaned
carefully and packed shatter-proofed. You have to enclose a
notice of return with detailed defect description when
sending the device. This form can be provided by PCE
Instruments. If your device came in contact with harmful
substances, a declaration of decontamination is additionally
required. Should you dispatch a device without a
declaration of decontamination and if there are any doubts
in our service department regarding the used medium,
repair will not be started until an acceptable declaration is
sent.
If the device came in contact with hazardous
substances, certain precautions have to be
complied with for purication!
10 Warranty conditions.
The warranty conditions are subject to the legal warranty
period of 24 months from the date of delivery. In case of
improper use, modications of or damages to the device, we
do not accept warranty claims. Damaged diaphragms will
also not be accepted. Furthermore, defects due to normal
wear are not subject to warranty services.
11 Declaration of conformity / CE.
The delivered device fulls all legal requirements. The
applied directives, harmonised standards and documents
are listed in the EC declaration of conformity.
Additionally, the operational safety is conrmed by the CE
sign on the manufacturing label.
12. Menu list
13. Disposal
The device must be disposed according to the
European Directives and 2002/96/EG
2003/108/EG (on waste electrical and electronic
equipment Waste of electrical and electronic )
equipment may not be disposed by domestic
refuse!
WARNING Depending on the measuring medium, !
deposit on the device cause danger for the user may
and the environment. Comply with adequate
precautions for purication and dispose of it properly.
limit exceeding
neg. / pos.
symbol for
indicat lowe
batteries
unit
measured value
1 P MIN
Minimum pressure display
▼–button: puts the current pressure as minimum value
▲–button: puts the value on zero
2 P MAX
Maximum pressure display
▼–button: puts the current pressure as maximum value
▲–button: puts the value on zero
3 LOWER
Displaying of the lower range
This value was determined on the order and cannot be changed.
4 UPPER
Displaying of the upper range
This value was determined on the order and cannot be changed.
5 DECIMA
Setting of the decimal point position
Depending on the nominal pressure range and on the set unit, only a limited number of positions after
the decimal point can be displayed.
6 UNIT
Setting of the pressure unit
Permissible units: bar, mbar, PSI, InHg, cmHg, mmHg, hPa, kPa, Mpa, mH
2O, InH2O.
Along with the unit, the decimal point position has probably to be changed in order to get a correct
indication of the measured value. Besides, depending on the nominal pressure range, perhaps not all
available units can be used.
7 SW OFF
Configuration of the switch- off automatic
Meaning of the permissible number:
"0": switch-o automatic is turned o
"1" "5": automatic switch-o in 1 to 5 minutes
8 CAL ZP
Calibration of initial point
If you detect a shifting of the measured value deviating from the oset, the display can be re-calibrated. For
this, a pressure reference is necessary if the oset diers from the ambient pressure. The used pressure
must be identical to the starting point of the pressure measuring range. For reading the new pressure into
the device, push the ▲ button.
Please note the following diviation:
- the oset is calibrated at -0.9 bar; during calibration we check whether the device will be within 1 … x bar:
tolerance at -1 bar (in theory); for re-calibration a pressure reference of -0.9 bar is necessary
0 … x bar abs.: the oset is calibrated at 0.1 bar abs.; during calibration we check whether the device will
be within tolerance at 0 bar abs.; for re-calibration a pressure reference of 0.1 bar is necessary
If the -calibration leads to a worsening of the original calibration, e. g. as a result of a defect pressure re
reference, the defaults can be re-set by the menu item "LD FAC" according to your order
9 CAL EP
Calibration of end point
If you detect a shifting of the measured value deviating from the end point, the display can be re-calibrated.
For this, a pressure reference is necessary if the oset diers from the ambient pressure. The used pres-
sure must be identical to the end point of the pressure measuring range. For reading the new pressure into
the device, push the ▲ button.
If the re-calibration leads to a worsening of the original calibration, e. g. as a result of a defect pressure
reference, the defaults can be re-set by the menu item "LD FAC" according to your order.
10 LD FAC
Load defaults
To load the defaults you have to push the ▲button. After the action "LOADED" and "OK" appers in the
display for a short time. The conguration mode will be left automatically.


Produkt Specifikationer

Mærke: PCE Instruments
Kategori: Måling
Model: PCE-DMM 20

Har du brug for hjælp?

Hvis du har brug for hjælp til PCE Instruments PCE-DMM 20 stil et spørgsmål nedenfor, og andre brugere vil svare dig