Læs gratis den danske manual til PCE Instruments PCE-DPD-F1 (16 sider) i kategorien Måling. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 2 anmeldelser. Har du et spørgsmål om PCE Instruments PCE-DPD-F1, eller vil du spørge andre brugere om produktet?

Side 1/16
Output and control opons
DIGITAL PANEL METERS
Modular output and control opons for panel meters from series PCE-DPD (except PCE-DPD-U). Relay
outputs, transistor outputs, SSR control outputs, analog outputs, Modbus RTU communicaons, RS-
485 and RS-232 communicaons.
PANEL METERS . OUTPUT AND CONTROL OPTIONS
4908E
www.pce-instruments.com
2
PCE Instruments PCE Instruments | www.pce-instruments.com
Index
1.1 Read this rst . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 Modular architecture. . . . . . . . . . . . . . . . . . . . 2
1.3 Installaon and start-up . . . . . . . . . . . . . . . . . . 2
1.4 To open the housing . . . . . . . . . . . . . . . . . . . . 3
1.5 Internal modules . . . . . . . . . . . . . . . . . . . . . . 3
1. Opons PCE-DPD/R, PCE-DPD/T and PCE-DPD/SSR . . . . . 4
2. Opon PCE-DPD/AV . . . . . . . . . . . . . . . . . . . . . . 5
2.1 Conguraon menu . . . . . . . . . . . . . . . . . . . . 6
2.2 Error codes . . . . . . . . . . . . . . . . . . . . . . . . . 6
3. Opon PCE-DPD/
MB . . . . . . . . . . . . . . . . . . . . . . . .7
3.1 Accessible registers. . . . . . . . . . . . . . . . . . . . . 7
3.2 Conguraon menu . . . . . . . . . . . . . . . . . . . . 8
3.3 Excepon codes. . . . . . . . . . . . . . . . . . . . . . . 8
3.4 Descripon and example of registers . . . . . . . . . . . 9
4. Opon PCE-DPD/485. . . . . . . . . . . . . . . . . . . . . . 10
4.1 Accessible registers. . . . . . . . . . . . . . . . . . . . . 10
4.2 Conguraon menu . . . . . . . . . . . . . . . . . . . . 11
4.3 Frame types . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.4 Frame structure. . . . . . . . . . . . . . . . . . . . . . . 12
4.5 Error codes . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.7 Frame examples . . . . . . . . . . . . . . . . . . . . . . 13
4.7.1 Frames ‘RD’ (36) and ‘ANS’ (37) . . . . . . . . . . . .13
4.7.2 Frames ‘ERR’ (38) . . . . . . . . . . . . . . . . . . . .13
4.7.3 Frames ‘PING’ (32) and ‘PONG’ (33). . . . . . . . . . 13
4.6 CRC calculaon . . . . . . . . . . . . . . . . . . . . . . .13
5. Opon PCE-DPD/232. . . . . . . . . . . . . . . . . . . . . . 14
All modules menoned in this document are compable with digital
panel meters PCE-DPD series (except mulinput panel meter PCE-
DPD-U). Dierent series dier in the number of digits, the digit height
and the number of output and control opons they can accept.
The output and control modules menoned in this document, are
covered by the warranty of the instrument where they are installed.
Check the users manual of the instrument for more informaon re-
lated to warranty.
The users manual of the instrument where the module is
installed, has important informaon related to installaon
that applies also to the output and control modules men-
oned in this document. Check the users manual of the
instrument for more informaon related to installaon precauons.
The output and control modules menoned in this docu-
ment are covered by the ‘CE declaraon of conformityof
the instrument where they are installed. Check the users
manual of the instrument for more informaon related to
the CE declaraon of conformity.
1.1 Read this rst
Digital panel meters from series M, K and S are designed following a
modular architecture that allows the operator to install any od the
output and control modules menoned in this document.
1.2 Modular architecture
1.3 Installaon and start-up
To install an oponal output and control module into a digital panel
meter from series PCE-DPD:
1. open the housing of the instrument (see secon 1.4)
2. install the module at slot Opt.1’, ‘Opt.2’ or ‘Opt.3’ as preferred and
close the instrument
3. close the housing of the instrument (see secon 1.4)
4. if needed, congure the appropriate jumpers at the module
5. connect the signal output terminals
6. congure the parameters at the ‘Conguraon menu’.
• modules PCE-DPD/R, T1 and SSR are congured from the alarms
menu of the instrument where the module has been installed
• other modules are congured from its own conguraon menu,
accessible from menu entries ‘Opt.1’, ‘Opt.2’ or ‘Opt.3’, depending
on the slot where the module has been installed.
!