Læs gratis den danske manual til PCE Instruments PCE-DPD-F2 (32 sider) i kategorien Måling. Denne vejledning er vurderet som hjælpsom af 11 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 6 anmeldelser. Har du et spørgsmål om PCE Instruments PCE-DPD-F2, eller vil du spørge andre brugere om produktet?

Side 1/32
PCE-DPD-F1
PCE-DPD-F2
Panel meter for load cells
Digital panel meter for load cells. Provides excitaon voltage to power up to 8 cells. Standard
96 x 48 mm size (1/8 DIN). Reading with 6 digit display. Accepts 4 and 6 wire load cells, includes ‘sense’
funcon, fast access to alarm setpoints, tare and auto-tare’ funcons, on power up’ funcons, stabil-
ity alarms, congurable operator menu, congurable led brightness. Universal AC and DC power. Up
to 3 oponal modules for output and control (relays, transistor, control SSR, analog outputs, Modbus
RTU communicaons, RS-485 ASCII, RS-232, ...)
www.pce-instruments.com
DIGITAL PANEL METERS
4784r03
User’s Manual
2
1. Panel meter PCE-DPD-F1 & F2
Panel meter for load cells, size 96 x 48 mm (1/8 DIN)   
Digital panel meter, with 96 x 48 mm (1/8 DIN) size and 6
digits with 14 mm digit height, for load cell signals. Pro-
vides excitaon voltage congurable to +5 Vdc or +10 Vdc
to power up to 8 standard 350 Ohms cells. Scalable read-
ing from 999999 to -199999 with congurable decimal
point.
Tare funcon, with congurable controls, and ‘auto-tare’
funcon for automac tare correcon when weight is re-
moved from the cell. Three working modes with dierent
acquision speeds and noise rejecon to 50 and 60 Hz.
Output and control opons with 1, 2 and 3 relays, isolated
analog outputs, Modbus RTU communicaons, transistor
outputs, SSR control outputs, RS-485 ASCII and RS-232.
Independent alarms congurable as maximum or mini-
mum, with acvaon at setpoint or when reading is
stable, with 1 or 2 setpoints per alarm, hysteresis, inde-
pendent acvaon and deacvaon delays, congurable
inverted acvaon of the relay and congurable locked
alarms (see secon 1.13.8).
Front protecon IP65. Connecons by plug-in screw ter-
minals. For industrial applicaons.
Funcons included :
tare accessible from frontal key or rear contact
(see sec-
on 1.11)
automac ‘auto-tare’ funcon (see secon 1.13.4)
access to gross weight value and tare value (see sec-
on 1.9.5)
funcon On Power Up for automac acvaon of
funcons at start-up (see secon 1.13.14)
scale factor for easy modicaon of reading units (see
secon 1.13.5)
‘stock units funcon to count units (see secon 1.13.6)
access to the measured signal value (in mV), excitaon
current provided (in mA) and real excitaon voltage (see
secon 1.13.13)
congurable Fast accessmenu (key ‘UP ( )) with 5
access to selected funcons (see secon 1.13.13)
Mulple display lters, memory for maximum and mini-
mum, password, 5 congurable brightness levels.
1. Power and signal connecons
- connect the power (see secon 1.8)
- connect the signal (see secon 1.8)
- read recommendaons to connect the ‘sense(see secon
1.8.1) and for load cell ground connecons (see secon
1.8.2)
2. Inial setup (see secon 1.13.2)
- theorecal conguraon of the cell (obtain the load cell
data : sensivity, load and excitaon) and congure the
instrument
- apply the empirical conguraon of the cell (apply the
high and low ‘eld correcon’)
- assign the ‘system zero’
3. Advanced conguraon (oponal) (see secon 1.13.7)
- tare conguraon, see secons 1.11 and 1.13.4
1.1 How to use this manual
- funconstock units(see secon 1.13.6)
- scale factor (see secon 1.13.5)
- acquision modes (see secon 1.9.1)
4. Congure the alarms (oponal) (see secon 1.13.8)
5. Display lters (oponal) (see secon 1.13.10)
6. Congure operator controls (oponal)
- congure the rear control (see secon 1.13.11)
- congure the front key ‘LE (3)(see secon 1.13.12)
- congure the fast access (key UP’ ( ))
5(see secon 1.13.13)
7. Congure other funcons (oponal)
- congure theon power up’ funcon (see secon 1.13.14)
- congure the password and brightness level (see secon 1.13.17)
8. Congure the output and control opons: analog or serial
(see secon 1.13.18)
If this is the rst me you are conguring this instrument,
below are the steps to follow to install and congure the in -
strument. Read all the manual secons in order to have a
full and clear view of the characteriscs of the instrument.
Do not forget to read the installaon precauons
at secon
1.19
.