Læs gratis den danske manual til PCE Instruments PCE-DPD-U (28 sider) i kategorien Måling. Denne vejledning er vurderet som hjælpsom af 35 personer og har en gennemsnitlig bedømmelse på 4.2 stjerner ud af 18 anmeldelser. Har du et spørgsmål om PCE Instruments PCE-DPD-U, eller vil du spørge andre brugere om produktet?

Side 1/28
PCE-DPD-U
Mulsignal panel meter
Mulsignal digital panel meter, congurable to work as AC and DC voltmeter (up to 600 Vac / dc), AC and DC
ammeter (up to 5 Aac / dc), accepts process signals (mA, Vdc), thermocouples, resisve temperature probes
(Pt, Ni, PTC and NTC), resistances, potenometers and frequency. Congurable. Standard 96 x 48 mm size
(1/8 DIN). Scalable reading with 4 digits (9999 / -1999). ‘Fast access’ funcon to alarm setpoints, ‘external
control’ to acvate predened funcons, ‘Eco’ mode for low consumpon, selectable dual scaling, 5 levels
of congurable brightness. Single universal power supply 18 to 265 Vac/dc. Oponal modules for output
and control (relays, analog output, Modbus RTU).
User’s Manual
PANEL METERS
4822r06
www.pce-instruments.com
2
1. Panel meter PCE-DPD-U
Mulsignal 96x 48 mm panel meter   
Mulsignal digital panel meter in 96 x 48 mm size (1/8 DIN). Accepts
AC and DC voltage signals from mV up to 600 V and currents up to
5 A (AC measures in True RMS), process signals (mA and Vdc) with
excitaon voltage included, thermocouples K, J, E, N, L, R, S, B, T and
C, resisve temperature probes (Pt100, Pt500, Pt1000, Ni100, Ni200,
Ni1000, PTC and NTC), resistances, potenometers and frequency.
Scalable reading with 4 digits up to 9999 / -1999 with congurable
decimal point. Two independent alarms, congurable as maximum
or minimum, with hysteresis and setpoint.
Oponal 1 or 2 relay outputs, 4/20 mA isolated analog output, and
Modbus RTU isolated serial communicaons.
Front protecon IP50, with oponal IP65. Connecons with plug-in
screw terminals.
Index
1. Panel meter PCE-DPD-U . . . . . . . . . . . . . . . . . . . . 2
1.1 How to order . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 Front view . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3 Rear view . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.4 Power connecons . . . . . . . . . . . . . . . . . . . . . 3
1.5 Signal connecons . . . . . . . . . . . . . . . . . . . . . 3
1.6 Mechanical dimensions (mm) . . . . . . . . . . . . . . . 3
1.7 Installaon and start-up . . . . . . . . . . . . . . . . . . 3
1.8 Technical specicaons . . . . . . . . . . . . . . . . . . 4
1.9 Internal jumpers . . . . . . . . . . . . . . . . . . . . . . 5
1.10 Measuring AC voltages and AC currents. . . . . . . . . 6
1.11 Measuring DC voltages and DC currents . . . . . . . . 7
1.12 Measuring thermocouples . . . . . . . . . . . . . . . . 8
1.13 Measuring with Pt and Ni probes . . . . . . . . . . . . 9
1.14 Measuring with NTC probes . . . . . . . . . . . . . . .10
1.15 Measuring with PTC probes . . . . . . . . . . . . . . . 10
1.16 Process measures . . . . . . . . . . . . . . . . . . . . .11
1.17 Measuring frequency . . . . . . . . . . . . . . . . . . .11
1.18 Measuring resistances . . . . . . . . . . . . . . . . . . 12
1.19 Measuring potenometers. . . . . . . . . . . . . . . .12
1.20 ‘Fast access’ menu . . . . . . . . . . . . . . . . . . . . 13
1.21 Scaling . . . . . . . . . . . . . . . . . . . . . . . . . . .13
1.22 Oset reading . . . . . . . . . . . . . . . . . . . . . . . 13
1.23 ‘Eco’ mode. . . . . . . . . . . . . . . . . . . . . . . . . 13
1.24 External control . . . . . . . . . . . . . . . . . . . . . . 13
1.25 Second scaling. . . . . . . . . . . . . . . . . . . . . . . 13
1.26 To open the instrument. . . . . . . . . . . . . . . . . . 14
1.27 How to operate the menus. . . . . . . . . . . . . . . .15
1.28 Messages and errors . . . . . . . . . . . . . . . . . . .15
1.29 Conguraon menu. . . . . . . . . . . . . . . . . . . .16
1.29.1 Input signal ranges . . . . . . . . . . . . . . . . . . 16
1.29.2 Scaling . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.29.3 Alarms . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.29.4 Fast access . . . . . . . . . . . . . . . . . . . . . . . 18
1.29.5 Super fast access . . . . . . . . . . . . . . . . . . . 18
1.29.6 External control . . . . . . . . . . . . . . . . . . . .18
1.29.7 Menu ‘Tools’ . . . . . . . . . . . . . . . . . . . . . . 19
1.29.8 Conguring the opons. . . . . . . . . . . . . . . . 21
1.30 Full conguraon menu . . . . . . . . . . . . . . . . . 22
1.31 Precauons on installaon . . . . . . . . . . . . . . . .25
1.32 Factory conguraon . . . . . . . . . . . . . . . . . . .25
1.33 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . 25
1.34 CE declaraon of conformity . . . . . . . . . . . . . . . 25
2. Output and control modules . . . . . . . . . . . . . . . . . 26
2.1 Modules PCE-DPD-U/R1 and PCE-DPD-U/R2 (relay output) . 26
2.2 Module PCE-DPD-U/A1 (analog output) . . . . . . . . . 26
2.3 Module PCE-DPD-U/MB1 (Modbus RTU) . . . . . . . . . 27
Instrument designed for industrial use, highly exible, allows for in-
tegraon in mulple applicaons, reduced cost, excellent quality and
oponal customizaon available.
• ‘Fast access’ menu at front key UP ( ) congurable for fast access 5
to alarm setpoints (see secon 1.20).
• ‘ ’ mode reduces power consumpon Eco
(see secon 1.23).
• Simplied scaling conguraon .(see secon 1.21)
• Funcon ‘ ’ to acvate with a contact a predened external control
funcon (second scaling, decimal point, reading ‘hold’, ‘tare’, memo-
ry of maximum or minimum) .(see secon 1.24)
• 5 congurable brightness levels .(see secon 1.29.7)
1.1 How to order
PCE-DPD
Model Opon 1
U - -
-R1 (1 relay)
-A1 (analog output)
-MB1 (Modbus RTU)
-(empty)
-U
(Power supply
18...265 Vac/dc)
-
Opon 2
-R2 (1 relay)
-(empty)


Produkt Specifikationer

Mærke: PCE Instruments
Kategori: Måling
Model: PCE-DPD-U

Har du brug for hjælp?

Hvis du har brug for hjælp til PCE Instruments PCE-DPD-U stil et spørgsmål nedenfor, og andre brugere vil svare dig