Pentair Azur Manual


Læs gratis den danske manual til Pentair Azur (16 sider) i kategorien Vandpumpe. Denne vejledning er vurderet som hjælpsom af 23 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 12 anmeldelser. Har du et spørgsmål om Pentair Azur, eller vil du spørge andre brugere om produktet?

Side 1/16
English Deutsch
Nederlands
Español Italiano
2
4
6
8
10
12
INSTALLATION GUIDE / INSTALLATIEHANDLEIDING
BEDIENUNGSANTLEITUNG / GUIDE DE LINSTALLATION
GUIA DE INSTALACION / GUIDE ALLINSTALLAZIONE
Français
FILTER SYSTEM
AZUR WITH SWIMMEY/ FREEFLO
IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
AQUATIC SYSTEMS G-FSB-SWM (Rev. 12/2013)
Customer Support
HERENTALS, BELGIUM (8:30 A.M. to 4:30 P.M.) CET
Website: www.pentairpooleurope.com
Declaration of Conformity
We declare, under our sole responsibility, that the product identied in
this declaration, and to which this declaration relates, are in conformity
with the protection requirements of Council Directive 2006/42/EG
The manufacturer, Pentair, has the right to modify the
products without previous notice for as far as their
characteristics are not really changed by this.
© 2013 Pentair. All rights reserved
This document is subject to change without notice
Trademarks and disclaimers: FreeFloTM, SwimmeyTM,, AzurTM and Pentair® are
trademarks and/or registered trademarks of Pentair and/or its aliated
companies. Unless noted, names and brands of others that may be used
in this document are not used to indicate an alitation or endorsement
between the proprietors of these names and brands and Pentair. Those
names and brands may be the trademarks of those parties or others.
IMPORTANT SAFETY PRECAUTIONS
ENGLISH INSTRUCTIONS
The manufacturer has the right to modify the products
without previous notice for as far as their characteristics
are not really changed by this.
Technical information
Maximum working pressure 2 bar
Maximum working temperature 35° C
Voltage 230 V
Rpm at 50 Hz 2800 min-1
Protection IP 44
Isolation F
Sound pressure level of kit > 70 dB (A)
2. GENERAL
Check ltration kit for any evidence of damage due
to rough handling in shipment. If ltration kit is
damaged notify the carrier immediately. The ltration
kit may only be used for the ltering of swimming pool
water, garden pond water or similar applications.
3. INSTALLATION INSTRUCTIONS
Please note: there can be specic needs to use
ltration kits nearby swimming pools, garden ponds
or such places.
The pump should be placed on a at, solid foundation,
high enough to prevent ooding of the motor.
Install the lter and pump in a sheltered location,
ensuring ventilation and adequate access for
servicing. Place the lter in its permanent loca-
tion. Make sure you can reach the valve easily. Then
x the piping. Use only plastic piping. Size all piping
adequately and keep the number of elbows to a
minimum. Use a direct and short suction line with
continuous slope in order to avoid long priming times.
It is essential that the suction line is free of air leaks.
The suction line should always have at least the same
size as the suction inlet of the pump.
4. OPERATION
Look inside and check lower distribution system (6) on
broken or loose laterals (5). Fill tank for 1/3 with water.
Before lling the lter, sand guide (10) should be on
the pipe (4). Fill the lter with the specied quantity of
gravel, afterwards with sand. Remove the sand guide.
Put some vaseline on the O-ring (7) of the valve (8).
Assemble the valve (8) to the lter and tighten with
the clamp ring (9). Connect the piping. Turn the valve
into position “Rinse and start the pump for at least 1
minute. Before starting the pump, the strainer basket
should be lled with water up to the level of the suc-
tion line. Lubricate the lid O-ring with silicone each
time the lid is removed. Energize the motor, the pump
will prime. The priming time depends on the suction
lift and distance to the pool. Five minutes is a reason-
able time. Pump will not lift more than 2 meter.
If pump does not prime, see troubleshooting guide.
CAUTION: NEVER SHIFT VALVE HANDLE POSITION
WHILE PUMP IS RUNNING. NEVER DISASSEMBLE
VALVE WHILE FILTER IS UNDER PRESSURE.
5. FILTRATION
1. Shift valve handle to position “Filtration
2. Start the pump
3. Note here the pressure of the pressure gauge (11).
6. TO CLEAN ( BACKWASH) THE FILTER
When the pressure rises approximately 0.5 bar above
the recorded pressure it is time to backwash.
1. Shut o the pump
2. Shift the valve handle to “Backwash”
3. Start pump and let it run until water is clean
(about 3 minutes).
4. Shut o the pump
5. Shift valve handle to position “Rinse” and start the
pump
6. Start pump and run for approximately one minute
7. Shut o the pump
THESE OPERATING INSTRUCTIONS CONTAIN IMPORTANT
INFORMATION ON THE SAFE, PROPER AND ECONOMICAL OPERATION
OF THE SWIMMING POOL PUMP. STRICT OBSERVATION OF THE
OPERATING INSTRUCTIONS WILL HELP TO AVOID DANGERS,
REDUCE REPAIR COSTS AND SHUTDOWN TIMES AND INCREASE THE
RELIABILITY AND WORKING LIFE OF THE PRODUCT.
Filter area (m²) 0.05 0.11 0.18 0.25
Filter ow rate 5 6 9 12
Gravel Ø 3-5 mm (kg) 5 12 15 20
Sand Ø 0.35-0.5mm (kg) 15 30 65 120
Filter empty weight (kg) 11 15 18 24
Ø 305 Ø 375 Ø 475 Ø 560