Phoenix UPS-BAT/LI-ION/24DC/120WH Manual

Phoenix power bank UPS-BAT/LI-ION/24DC/120WH

Læs nedenfor 📖 manual på dansk for Phoenix UPS-BAT/LI-ION/24DC/120WH (66 sider) i kategorien power bank. Denne guide var nyttig for 7 personer og blev bedømt med 4.2 stjerner i gennemsnit af 4 brugere

Side 1/66
Power Supplies
User Manual
UPS-CONF
Order No.: -
Configuration and Management Software
UPS-CONF
2.1 System requirements
In order to run the UPS-CONF software, your computer must meet the following software and
hardware requirements:
Software requirements
Supported operating systems:
- Windows 7, 32bit and 64bit
- Windows Vista SP1
- XP SP3 (requires .NET Framework 3.5 SP1)
Supported browser: Internet Explorer version 6 or later
Hardware requirements
CPU 1 GHz min.
2 GHz recommended
Windows 7
Windows Vista SP1
Pentium III 1GHz min.
2 GHz recommended
Windows XP SP3
Main memory 1 GB RAM min.
2 GB RAM recommended
Windows 7
Windows Vista SP1
512 MB RAM min.
1 GB RAM recommended
Windows XP SP3
Main memory used by UPS-CONF max. 96 MB
Hard disk drive (recommended)
Hard disk used by UPS-CONF
850 MB
max. 50 MB
CD-ROM drive not necessarily needed
Interfaces 1 x USB 2.0
Monitor VGA, resolution 800 x 600 pixels minimum, 256 colors
Network Internet connection needed for program download
UPS-CONF
4
PHOENIX CONTACT 104779_en_01
4.3 Connecting the PC
A PC has to be connected to the UPS in one of the following cases:
You want to configure or monitor the UPS by the UPS-CONF software.
You want to display currently set QUINT-UPS parameters or modify them using UPS-
CONF.
You want to initiate a controlled PC shutdown in case of a mains failure and if battery
runs low.
NOTE
First, install the software (see page 5) and then connect the PC afterwards.
To connect the PC to the QUINT-UPS, proceed as follows:
1. Connect the USB connector of the IFS-USB-DATACABLE to a free USB connector of
your PC. After detecting the device, the used USB port is entered automatically in the
software settings of UPS-CONF.
2. Connect the other side of the IFS-USB-DATACABLE to the Data port of the UPS:
UPS-CONF
14
PHOENIX CONTACT 104779_en_01
Battery parameters Meaning
Quantity check o.k. Shows "Yes", if the number of installed bat-
tery units complies with the number of detec-
ted batteries. Otherwise "No" is displayed.
6.3 Battery Advanced
This navigation item is only available if the "Enable advanced views" checkbox is marked in
the software settings (see page 5).
If the "Battery Advanced" item is selected in the software menu "Status", advanced status
information for all connected batteries is shown in the action area.
In normal operation it looks something like this:
UPS-CONF
26
PHOENIX CONTACT 104779_en_01
A reported alarm is additionally signaled by the LED at the front of the UPS device as well as
in the status bar of the UPS-CONF software.
By means of warnings and alarms you can implement a two-level detection system:
1. Report a warning, when the first threshold value is exceeded.
Example: battery lifetime is still one year.
2. Report an alarm, when the second threshold value is exceeded.
Example: remaining lifetime of the battery is only some few months or weeks. Now an
Email is additionally sent to the responsible person to ensure that a new battery is
ordered in time.
UPS-CONF
32
PHOENIX CONTACT 104779_en_01


Produkt Specifikationer

Mærke: Phoenix
Kategori: power bank
Model: UPS-BAT/LI-ION/24DC/120WH
Kode for international beskyttelse (IP): IP20
Bredde: 135 mm
Dybde: 110 mm
Højde: 202 mm
Vægt: 2900 g
Produktfarve: Grå
Batterispænding: 24 V
Batterikapacitet: 120 Wh
Indbygget skærm: Ingen
Batteriteknologi: Lithium-Ion (Li-Ion)
Opbevaringstemperatur (T-T): -40 - 65 °C
Driftstemperatur (T-T): -20 - 60 °C
Vandfast: Ingen
Certificering: IP20
Udgangsspænding: 24 V
Udgangsstrøm: 30 A
Indgangsspænding: 24 V
Opladningskilde: DC
Oprindelsesland: Kina

Har du brug for hjælp?

Hvis du har brug for hjælp til Phoenix UPS-BAT/LI-ION/24DC/120WH stil et spørgsmål nedenfor, og andre brugere vil svare dig