QUADRA-FIRE 2100 & 4300 MILLENIUM ACC WOOD BURNER INSTALLATION INSTRUCTIONS
INSTALLATIONS TO COMPLY WITH AS/NZS2918:2001
AND WILL REQUIRE A BUILDING CONSENT
IMPORTANT: Read all instructions carefully before starting installation. Failure to follow these
instructions may result in a re hazard and will void the warranty.
• Fig. 3,4,5 and Table 1 & 2 relate to installations with
tested ue systems; as per AS/NZS 2918:2001 -
Appendix F, with a ceiling angle between 0° - 30°
inclusive.
• For installations with a ceiling angle greater than 30°,
refer to Fig. 6 & 7 and AS/NZS 2918:2001 4.6.3(b)
• Ceiling Plate may vary in size depending on ceiling
angle. Please specify ceiling pitch prior to ordering the
ceiling plate.
• Quadra-Fire 2100 & 4300 Millenium ACC wood
burner’s are tested and approved to the N.Z. National
Environmental Standards;
21M-ACC-NZ - 2100 Millenium ACC Softwood Certied
Particulate Emissions = 0.6 g/kg Space Heating Efciency = 72%
21M-ACC-AU - 2100 Millenium ACC Hardwood Certied
Particulate Emissions = 2.0 g/kg Space Heating Efciency = 81%
43M-ACC-NZ - 4300 Millenium ACC
Softwood Particulate Emissions = 0.4 g/kg Space Heating Efciency = 71%
Hardwood Particulate Emissions = 2.5g/kg Space Heating Efciency = 78%
Model:
21M-ACC-NZ
21M-ACC-AU
43M-ACC-NZ
• Do not store or use gasoline or other am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not over re - If appliance or chimney
connector glows, you are over ring. Over
ring will void your warranty.
• Comply with all minimum clearances to
combustibles as specied. Failure to com-
ply may cause house re.
WARNING
If the information in these instruc-
tions is not followed exactly, a re
could - result causing property dam
age, personal injury, or death.
WARNING
Fire Risk.
For use with solid wood fuel only.
Other fuels may over re and generate poisonous
gases (i.e. carbon monoxide).