Conguration and data viewing
software freely downloadable
KT 50 - KH 50
KISTOCK Data logger
or HVAC - Temperature, Humidity
Conguration and data processing
software available as option
16,000 measurement points
2 congurable setpoint alarms
1 line LCD display
Fast data download (1,000 values/second)
IP65 (KT 50) and IP20 (KH 50) housing
DATA SHEET
KT 50 KH 50
Units displayed °C, °F °C, °F, %RH
Resolution 0.1 °C, 0.1 °F 0.1 °C, 0.1 °F, 0.1 %RH
External inputs Micro-USB connector
Internal sensor Temperature Humidity, temperature
Setpoints alarm 2 setpoint alarms on each channel
Frequency of measurement From 1 minute to 24 hours
Operating temperature
(1)
From -40 to +70 °C
-40 to +158 °F
From -20 to +70 °C
-4 to +158 °F
Storage temperature From -20 to +50 °C / -4 to +122 °F
Battery life 500 days
(2)
365 days
(2)
Standards
2014/30/EU EMC; 2014/35/EU Low Voltage;
2011/65/EU RoHS II; 2012/19/EU WEEE;
FCC part 15; UL 61010
General features
Magnetic
mounting
(1)
The screen can be hard to read, and its display speed often slows down at temperatures lower than 0 °C / 32 °F. This has no effect on the accuracy of measurements.
(2)
Non-contractual value. Based on 1 measurement each 15 minutes at 25 °C / 77 °F. A correct operation of the device and the storage conditions must be respected.
°C
°F
Housing
Dimensions 61.3 x 40 x 21.9 mm / 2
13
/
32
’ x 1
9
/
16
’ x
7
/
8
Weight 40 g / 1.42 oz
Display
1 line LCD screen
Screen dimensions: 26.5 x 22.5 mm / 1
3
/
64
‘ x
57
/
64
Control 1 OK key
Material
Compatible with food industry environment
ABS housing. Caps made of Elastomer
Protection rating IP65: KT 50. IP20: KH 50
PC communication 1 micro USB input
Battery power supply 2 x CR2032 (lithium 3 V)
Environmental
conditions of use
Hygrometry: in non-condensing condition
Maximum altitude: 2000 m / 2188 yd
Air and neutral gases
KT 50 TemperatureInternal sensor
Type of sensor NTC
Measuring range From -40 to +70 °C / -40 to +158 °F
Accuracy*
±0.4 °C from -20 to 70 °C ±0.8°C below -20 °C
±0.8 °F from -4 to 158 °F ±1.5 °F below -4 °F
Technical specications
* All accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for
measurements carried out in the same conditions, or carried out with calibration compensation.
** Factory calibration uncertainty: ±0.88 %RH. Temperature dependence: ±0.04 x (T-20) %HR if T<15 °C or T>
25 °C / ±0.04 x [((T°F - 32) x 5/9) -20] %RH (if T<59°F or T>77°F).
KH 50 Hygrometry TemperatureThermo-hygrometer
Type of sensor Capacitive NTC
Measuring range From 0 to 100% RH
From -20 to +70 °C
-4 to 158 °F
Accuracy*
±2.5 %RH (from +15
to +25°C / +59 to
+77 °F from 5 to 95
%RH)**
±0.4 °C from 0 to +50 °C
±0.8 °F from +32 to +122 °F
±0.8 °C below 0 °C or
above +50 °C
±1.5 °F below 32 °F or
above 122 °F
EN 12830
KT 50


Produkt Specifikationer

Mærke: Sauermann
Kategori: Måling
Model: KH 50

Har du brug for hjælp?

Hvis du har brug for hjælp til Sauermann KH 50 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måling Sauermann Manualer

Sauermann

Sauermann KPA 320 Manual

17 September 2025
Sauermann

Sauermann KP 320 Manual

16 September 2025
Sauermann

Sauermann KP 321 Manual

16 September 2025
Sauermann

Sauermann KTT 220 Manual

16 September 2025
Sauermann

Sauermann Si-VH 3 Manual

16 September 2025
Sauermann

Sauermann KTT 320 Manual

27 August 2025
Sauermann

Sauermann LV 130 Manual

27 August 2025
Sauermann

Sauermann KCC 320 Manual

27 August 2025
Sauermann

Sauermann KH 50 Manual

27 August 2025
Sauermann

Sauermann MP 120L Manual

26 August 2025

Måling Manualer

Nyeste Måling Manualer