Sauermann Si-AQ Pro Manual

Sauermann Måling Si-AQ Pro

Læs gratis den danske manual til Sauermann Si-AQ Pro (2 sider) i kategorien Måling. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 2 anmeldelser. Har du et spørgsmål om Sauermann Si-AQ Pro, eller vil du spørge andre brugere om produktet?

Side 1/2
DATA SHEET
SI-AQ PRO
The Latest in Handheld IAQ Monitoring
& Real Time Data Logging for Complete
Air Quality Analysis
Accurate / Reliable / Robust / Fast
Up to 3 Gases
Temp., %RH, & Barometric
Real-Time Data Logging
Active Internal Sampling Pump
Large Internal Memory (2,000 Tests)
Protective Magnetic Rubber Boot
Optional Wireless Printer
Optional Handheld Probe
Select Up To 3 Gases:
CO
2
, CO, NO
2
,
NO, O
2
, SO
2
,
H
2
S, Formaldehyde
Long Lasting Rechargeable
Battery & AC Charger
Light Weight & Durable
Si-AQ PC Software
& USB Cable
FT_EN – Si-AQ Pro – 12/10/2020 – Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Relative Humidity Capacitive 5 - 95 % 0.1 % ±2 % RH
Ambient Temperature Pt100
-40 to 257 °F
-40 to 125 °C
0.1 °F
0.1 °C
±0.4 °F (32 - 140 °F)
±0.4 °C (0 - 60 °C)
Barometric Pressure Piezoresistive 260 - 1,260 mbar 1 mbar ±2 mbar
Differential Pressure* Piezoresistive
-40 inH
2
O to 40 inH
2
O
-100 mbar to 100 mbar
0.1 inH
2
O
0.1 mbar
±1 % rdg
Temperature Type K T1 Tc K
0 - 2,000 °F
0 - 1,100 °C
1 °F
1 °C
5 °F / 3 °C
or 2 % rdg
Air Velocity Calculated
0 - 300 ft/sec
0 - 91 m/s
1 ft/sec
1 m/s
-
Electromagnetic
Compatibility
EN 61326-1, Portable Equipment
All Si-AQ Pro Kits include:
Temperature, %RH, Wet Bult, Dew Point
Barometric Pressure
PC Software & USB Cable
Real-Time Continuous Data Logging
Bluetooth
®
Connectivity
Continuous Active Internal Sampling Pump
Differential Pressure*
Long Lasting Battery & AC Charger
Factory Calibration Certicate
Quick Start Guide
Si-AQ CO
2
Sensor
(0 - 5000 ppm)
Carbon Dioxide (CO
2
NDIR 0 - 5,000 ppm 1 ppm ±2 % rdg ±10 ppm
Si-AQ CO Cell
(0 - 200 ppm)
Carbon Monoxide (CO)¹
EC
2,5
0 - 200 ppm 0.1 ppm ±4 % rdg ±0.5 ppm
Si-AQ CH
2
O Cell
(0 - 10 ppm)
Formaldehyde
3,4
EC
2,5
0 - 10 ppm
0 - 10,000 ppb
1 ppb ±5 % rdg ±50 ppb
Si-AQ H
2
S Cell
(0 - 100 ppm)
Hydrogen Sulde (H
2
S)¹
EC
2,5
0 - 100 ppm 1 ppm ±4 % rdg ±0.5 ppm
Si-AQ NO
2
Cell
(0 - 20 ppm)
Nitrogen Dioxide (NO
2
EC
2,5
0 - 20 ppm 0.1 ppm ±4 % rdg ±0.5 ppm
Si-AQ O
2
Cell
(0 - 25%)
Oxygen (O
2
)
EC
2,5
0 - 25 % 0.1 % ±0.1 % vol rdg
Si-AQ SO
2
Cell
(0 - 20 ppm)
Sulfur Dioxide (SO
2
EC
2,5
0 - 20 ppm 0.1 ppm ±4 % rdg ±0.5 ppm
Si-AQ NO Cell
(0 - 250 ppm)
Nitric Oxide (NO) ¹
EC
2,5
0 - 250 ppm 0.1 ppm ±4 % rdg ±0.5 ppm
Si-AQ Pro Ordering Code
Example Part #: PRO - Si-AQ CO
2
Sensor (0 - 5000 ppm) - Si-AQ CO Cell
(0 - 200 ppm) - Si-AQ H
2
S Cell (0 - 200 ppm) = CO
2
, CO,
H
2
S
Sensor Range Resolution Accuracy
1
Other ranges are available upon request
2
Electrochemical
3
Accuracy based on laboratory conditions
4
This sensor may have interference from H
2
, CO,
H
2
S and other reducing gases such as alcohols
5
Maximum of TWO (2) Electrochemical (EC) Sensors per unit
Optional Accessories
Parameter
Bluetooth
®
Printer
(Si-AQ Bluetooth
®
Printer)
Moisture Exchange
Tube for Calibration
(Si-AQ Moisture Exchange)
Sampling Probe
(Si-AQ Probe with Hose)
Pitot Tube for Air Velocity
(Si-AQ Pitot Tube)
Parameter Sensor Range Resolution Accuracy
* Requires connection accessories, exible tubes and connections available as option in the Si-AQ Kit Press. Diff.
www.sauermanngroup.com


Produkt Specifikationer

Mærke: Sauermann
Kategori: Måling
Model: Si-AQ Pro

Har du brug for hjælp?

Hvis du har brug for hjælp til Sauermann Si-AQ Pro stil et spørgsmål nedenfor, og andre brugere vil svare dig