Sauter FK 1K Manual


Læs gratis den danske manual til Sauter FK 1K (3 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 27 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 14 anmeldelser. Har du et spørgsmål om Sauter FK 1K, eller vil du spørge andre brugere om produktet?

Side 1/3
Instruction Manual
FK
AS, 03.04.2008 FK GB.doc Page 1 of 3
Thank you for buying a SAUTER force gauge. We hope
you are pleased with your high quality force gauge with its
big functional range. If you have any queries, wishes or
helpful suggestions, do not hesitate to call our service
number.
Sensor Inside“ means the measuring cell is inside the
housing.
1.
Included in delivery
- SAUTER FK
- Charger
- Standard Attachments as shown below
Terms:
Track = continuous measurement
Peak = Capture of the maximum value
Data in mm
2.
Working Conditions
10°C to 30°C / 15% up to 80% humidity
3.
Electrical Power Supply
Either by recharchable battery or current power supply
Current power supply:
- Connection by power adapter
- Recharchable batteries are charged
simultaneously
Recharchable battery pack for mobile applications:
- Type: AA Size 6 Batteries
- Charging time: approx 1 hour
4.
Technical Data
- Accuracy: ± 0,5 % of Capacity
- Data Sampling Rate: 1.000 Hz
Model Capacity Resolution
FK 10 10 N 0,005 N
FK 25 20 N 0,010 N
FK 50 50 N 0,020 N
FK 100 100 N 0,050 N
FK 250 200 N 0,100 N
FK 500 500 N 0,20 N
FK 1k 1 000 N 0,50 N
Sensor
Inside
LCD
Force Sensor
195 mm
83 mm
Instruction Manual
FK
AS, 03.04.2008 FK GB.doc Page 2 of 3
5.
Operation
a. Display
(1) Measuring Result
(2) Measuring Units
(3) Measuring Direction
(4) Indication of PEAK Mode
b. Operating keys
ON / OFF:
ON / OFF key
(For ON, press 1 sec.)
MAX:
Changes between Track and Peak mode (capture of
maximum values)
UNIT:
- Press short: Select unit:
N, kg, lb, ou
ZERO:
- Zeros the measuring result (Tara function)
- Cleans the peak value (in Peak mode)
c. Display Return
When the instrument itself is turned so that the head faces
down, the display returns automatically.
d. Measurement (Track Modus)
Display (1) shows the continuous force in a dened
direction (3)
To zero the display, press:
e. Peak-Hold Function (Peak Mode)
Please press:
6.
Backside Fixing to a test stand
Fixing by 4 x M3 scres.
7.
CE Declaration of Conformity
(1)
(2)
(3)
(4)


Produkt Specifikationer

Mærke: Sauter
Kategori: Ikke kategoriseret
Model: FK 1K

Har du brug for hjælp?

Hvis du har brug for hjælp til Sauter FK 1K stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Sauter Manualer

Sauter

Sauter ASU-01 Manual

8 Januar 2025
Sauter

Sauter FH 500S71 Manual

8 Januar 2025
Sauter

Sauter CE HSP Manual

8 Januar 2025
Sauter

Sauter FK 10 Manual

11 August 2024
Sauter

Sauter FA 200 Manual

6 August 2024
Sauter

Sauter FK 500 Manual

6 August 2024
Sauter

Sauter FK 1K Manual

5 August 2024
Sauter

Sauter FA 10 Manual

3 August 2024
Sauter

Sauter FL 200 Manual

3 August 2024
Sauter

Sauter FL 500 Manual

3 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer