Saxon 8710P3 Manual


Læs gratis den danske manual til Saxon 8710P3 (4 sider) i kategorien Vejrstation. Denne vejledning er vurderet som hjælpsom af 27 personer og har en gennemsnitlig bedømmelse på 4.2 stjerner ud af 14 anmeldelser. Har du et spørgsmål om Saxon 8710P3, eller vil du spørge andre brugere om produktet?

Side 1/4
1
Operation Instruction
. Main Functions:
1. Weather forecast for 5 states: sunny, semi-sunny, cloudy, rainy, cloudburst.
2. Time display (displaying month, date, day, hour, minute, second)
3. Indication of the trend of air pressure/temperature/humidity
4. Indication of the comfort index: dry, comfortable and wet.
5. Air pressure record of 12-hour
6. Units of air pressure for choice: mb/hpa, or inHg.
7. Calculation of sunrise and sunset time of 160 cities in Europe.
8. The indoor/outdoor temperature/humidity and Max/Min record.
9. Temperature alert.
10. Dual alarms.
11. Sunrise and Sunset display
12. Time display format for choice:12/24 hour.
13. Temperature display format for choice: /.
14. Moon phase calculated.
. Power-On or Reset
1. When Power-On or reset, LCD full displays for 3 seconds, and after a Beep” it begins testing indoor temperature, humidity and air
pressure.
2. The calendar defaults 0:00:00 January 1, 2007
3. Alarm defaults 0:00.
4. The weather icon defaults semi-sunny.
. Instruction of operating the KEYS
1. Key functions
Twelve functional keys: DOWN,UP, ALARM,TIME SET,LOCATION,SNOOZE,HISTORY,▲,
,ALERT,MAX/MIN,CHANNEL.
TIME SET
ALARM
UP
DOWN
SNOOZE
LOCATI
ON
Standard mode
Click
-----
Time
displaying /
alarm1/
Alarm2
------
Alarm on/off
-----
----
Hold
Enter into
time setting
Enter into
alarm setting
-----
-------
-----
Enter 160
cities set
Time set
Click
Confirm
the setting
-----
One step
forward
One step
backward
-----
-----
Hold
-----
-----
8steps/seco
nd forward
8steps/second
backward
-----
-----
Alarm set
Click
-----
Confirm the
setting
One step
forward
One step
backward
-----
-----
Hold
-----
-----
8steps/seco
nd forward
8steps/second
backward
-----
-----
City set
Click
-----
-----
One step
forward
One step
backward
-----
Confirm
the setting
Hold
-----
-----
8steps/seco
nd forward
8steps/second
backward
-----
-----
Channel
Alert
MAX/MIN
HISTORY
Standard
mode
Click
Exit RF
receiving
state/shift
channel
All the
MAX/MIN
temperature alert
on/off
°C/°F switchable
Showing the
Max value
----
Function
Operation
Function
Operation
2
Hold
Enter into
RF
registering
state
Enter into
temperature alert
setting
-----
Enter into
snooze state
Enter 160
cities set
Temperature set
Click
Choose the
channel
need to be
set
Confirm the
setting
One step
backward
-----
-----
Hold
-----
-----
8steps/second
backward
-----
-----
Height
set
Click
-----
-----
One step
backward
-----
-----
Hold
-----
-----
8steps/second
backward
-----
-----
TIME SET Key:
Hold TIME SET key for 2 seconds to enter into time setting mode, the sections being set will flash in the frequency of 1 Hz/second,
press UP or DOWNto choose the value needed then press TIME SET key to confirm the setting.
It will return to standard mode automatically, if there is no operation for more than 7 seconds.
ALARM Key
Click Alarm key to display alarm time, press once to display AL1; twice for Al2; thrice to return to standard state. Hold Alarm key
for 2 seconds to enter alarm setting, the sequence: AL1/ AL2 Hour Minute Exit.
It will return to standard mode automatically, if there is no operation for more than 7 seconds.
UP Key
Under setting mode, click UP Key to adjust one step (forward), holding the UP Key for 2 seconds to enter speedy adjusting mode (8
steps/seconds).
DOWN Key
Under setting mode, click DOWN Key to adjust one step (backward), holding the DOWN Key for 2 seconds to enter speedy
adjusting mode (8 steps/seconds).
Under standard mode, Click DOWN Key to turn alarm on/off, the setting sequence: AL1 on/ AL2 off AL2 on/ AL1 off AL1,
AL2 on AL1, AL2 off.
SNOOZE Key
When the alarm is ringing, click SNOOZE key to pause the alarm, and enter 5 minutes of snooze function.
LOCATION Key
Under standard mode, hold the LOCATION key for 2 seconds to enter city setting.
Under city setting state, hold UP or DOWN key to choose the city, and then click LOCATION key to confirm the setting and exit
the state.
CHANNEL Key
Under standard mode, click Channel key to shift RF channel, CH1CH2 CH3displaying circularly.
Under standard mode, hold Channel Key for 2 seconds to clean out RF registering state, temperature displays and MAX/MIN value.
Under Alert setting channel state, choose the needed setting channel..
MAX/MIN Key
Click Max/Min key to display MAX value of indoor/outdoor temperature, humidity for 5 seconds. Click once again to display the
MIN values for 5 seconds, click again to return to standard mode.
When it displays the Max or Min values, hold Max/Min key for 2 seconds to clear out the memory of the Max/Min values, then return to
normal standard state.
ALERT Key
Under standard mode, click Alert key to turn temperature alert on/off.
Under standard mode, hold Alert key for 2 seconds, it will enter temperature alert setting.


Produkt Specifikationer

Mærke: Saxon
Kategori: Vejrstation
Model: 8710P3

Har du brug for hjælp?

Hvis du har brug for hjælp til Saxon 8710P3 stil et spørgsmål nedenfor, og andre brugere vil svare dig