Senseca DX530 Manual


Læs gratis den danske manual til Senseca DX530 (12 sider) i kategorien Måling. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.7 stjerner ud af 2 anmeldelser. Har du et spørgsmål om Senseca DX530, eller vil du spørge andre brugere om produktet?

Side 1/12
Z03.0.0X.6C-13
Operating Manual
pH electrodes
GE xxx
Keep for later use.
www.senseca.com
English
Z03.0.0X.6C-13 Operating manual GE xxx serie page 2 of 12
Index
1 GENERAL NOTE ...................................................................................................................................... 2
2 SAFETY ....................................................................................................................................................... 2
2.1 INTENDED USE ........................................................................................................................................ 2
2.2 SAFETY GUIDELINES ................................................................................................................................ 3
2.3 SAFETY SIGNS AND SYMBOLS .................................................................................................................. 3
2.4 FORESEEABLE MISUSE ............................................................................................................................. 4
2.5 SAFETY INSTRUCTIONS ............................................................................................................................ 4
3 BASICS ........................................................................................................................................................ 6
3.1 PH MEASUREMENT .................................................................................................................................. 6
3.2 DESIGN OF ELECTRODE ............................................................................................................................ 6
3.3 FURTHER INFORMATION .......................................................................................................................... 7
3.4 SERVICE LIFE ........................................................................................................................................... 7
4 OPERATING AND MAINTENANCE ..................................................................................................... 7
4.1 MEASURING AND STORING ...................................................................................................................... 7
4.2 CALIBRATION .......................................................................................................................................... 8
4.3 CARE AND MAINTENANCE ....................................................................................................................... 9
5 CHOOSE THE RIGHT ELECTRODE.................................................................................................. 10
6 RESHIPMENT AND DISPOSAL ........................................................................................................... 11
6.1 RESHIPMENT ......................................................................................................................................... 11
6.2 DISPOSAL .............................................................................................................................................. 11
7 MANUFACTURER / DISTRIBUTER ................................................................................................... 11
8 SPECIFICATION ..................................................................................................................................... 12
1 General Note
Read this document carefully and get used to the operation of the product before you use it. Keep
this document within easy reach near the product for consulting in case of doubt.
2 Safety
2.1 Intended Use
The pH electrodes must be used only according to its intended purpose and under suitable conditions.
The electrodes must be operated with suitable measuring devices and be calibrated before first use
and afterwards in regular intervals.
The safety requirements (see below) have to be observed.
The life-time and accuracy of the electrodes depends on adequate selection as well as on proper
handling. Please consider therefore the chapters “Choose the right electrode”, “Measuring and storing”
and “Maintenance”.
Use the device carefully and according to its technical data (do not throw it, strike it, etc.). Protect
the device from dirt.
To be sure that there´s no risk arising due to misinterpretation of measured values, the operator
must have further knowledge in case of doubt - the user is liable for any harm/damage resulting
from misinterpretation due to insufficient knowledge.


Produkt Specifikationer

Mærke: Senseca
Kategori: Måling
Model: DX530

Har du brug for hjælp?

Hvis du har brug for hjælp til Senseca DX530 stil et spørgsmål nedenfor, og andre brugere vil svare dig