Læs gratis den danske manual til Servend Flomatic (8 sider) i kategorien Køleskab. Denne vejledning er vurderet som hjælpsom af 4 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 2.5 anmeldelser. Har du et spørgsmål om Servend Flomatic, eller vil du spørge andre brugere om produktet?

Side 1/8
Part Number 5027981 8/10
INSTALLATION INSTRUCTIONS
464, 424 & 324 POST-MIX VALVES
The Flomatic valves are available in manual, electric,
portion control and automatic fill models. All Flomatic
valves share the same mounting and flow control char-
acteristics. The 324 valves are also compatible with
the 300-Q mounting block. Those instructions are not
included here.
Prior to installation determine which mounting block
you need. The Flomatic mounting block kit 5007842
has inlet O rings sized for both inlet port sizes
(located at the rear of the block) port. Sized at 0.380
inches is compatible with most current mounting block
inlet fittings.
INSTALLATION / REPLACEMENT
Be sure to relieve system pressure prior to beginning
work. When replacing most other brand valves with
the Flomatic valve, remove the existing mounting
block and install the appropriate Flomatic mounting
block. This is an easy first step just align the four bolt
holes and mount. The Flomatic mounting blocks have
a positive shut off and mounting system to prevent
accidental removal while the system is pressurized.
The valve cannot be removed unless the shut-off
valves are in the closed position (arrows pointed
across the service line).
The hole pattern for most current valves will have key
slots for the product supply lines. Some older valve
mountings may require the use of the S clip 2 to hold
the product supply lines in place (available as an
option).
2 Part Number 5027981 8/10
Remove the valve cover
and align the valve stems
with the mounting block.
Engage the valve and
depress the latch pin. Do
not force the latch pin
down or you may bend
the latch pin. If you are
having difficulty, simply
re-engage the valve and
try again. Be sure the
valve base is completely
seated against the mount-
ing block. Open the shut-
off valves by turning 1/4
turn (arrows pointed
toward the service line) to
engage system pressure.
FLOW CONTROL & BRIX
Two simple adjustments are all you need to brix the
Flomatic valves. You will need a Flomatic S tube syrup
separator, 5/32 inch hex wrench, watch and brix cup.
Place the S-tube syrup separator over the syrup dif-
fuser and you are ready to
begin. You need not
remove the nozzle. Clock-
wise movement of the brix
nut adjustment screw
increases the flow rate and
vice versa. Restrict the flow
by withdrawing the brix nut
adjustment screw as far as
it will go (turn counterclock-
wise). At this point the flow
will be at a minimum.
The 424 or 324 ceramic
flow controls can be
adjusted from 1.5 oz. /sec.
to 3.0 oz. /sec. Turn the