Læs gratis den danske manual til Sirius 3RV2011-0HA10 (8 sider) i kategorien Afbryder. Denne vejledning er vurderet som hjælpsom af 50 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 25.5 anmeldelser. Har du et spørgsmål om Sirius 3RV2011-0HA10, eller vil du spørge andre brugere om produktet?

Side 1/8
Data sheet
Data sheet
Data sheet
Data sheetData sheet 3RV2011-0HA10
3RV2011-0HA10
3RV2011-0HA10
3RV2011-0HA103RV2011-0HA10
Circuit breaker size S00 for motor protection, CLASS 10 A-release
0.55...0.8 A N-release 10 A screw terminal Standard switching
capacity
Product brand name
Product brand name
Product brand name
Product brand nameProduct brand name SIRIUS
Product designation
Product designation
Product designation
Product designationProduct designation Circuit breaker
Design of the product
Design of the product
Design of the product
Design of the productDesign of the product For motor protection
Product type designation
Product type designation
Product type designation
Product type designationProduct type designation 3RV2
General technical data
Size of the circuit-breaker
Size of the circuit-breaker
Size of the circuit-breaker
Size of the circuit-breakerSize of the circuit-breaker S00
Size of contactor can be combined company-specific
Size of contactor can be combined company-specific
Size of contactor can be combined company-specific
Size of contactor can be combined company-specificSize of contactor can be combined company-specific S00, S0
Product extension
Product extension
Product extension
Product extensionProduct extension
● Auxiliary switch Yes
Power loss [W] total typical
Power loss [W] total typical
Power loss [W] total typical
Power loss [W] total typicalPower loss [W] total typical 6W
Surge voltage resistance rated value
Surge voltage resistance rated value
Surge voltage resistance rated value
Surge voltage resistance rated valueSurge voltage resistance rated value 6kV
maximum permissible voltage for safe isolation
maximum permissible voltage for safe isolation
maximum permissible voltage for safe isolation
maximum permissible voltage for safe isolationmaximum permissible voltage for safe isolation
● in networks with grounded star point between
main and auxiliary circuit
400V
● in networks with grounded star point between
main and auxiliary circuit
400V
Protection class IP
Protection class IP
Protection class IP
Protection class IPProtection class IP
● on the front IP20
● of the terminal IP20
3RV2011-0HA10 Subject to change without notice
Page 1/
8
06/07/2019 © Copyright Siemens
Shock resistance
Shock resistance
Shock resistance
Shock resistanceShock resistance
● acc. to IEC 60068-2-27 25g / 11 ms
Mechanical service life (switching cycles)
Mechanical service life (switching cycles)
Mechanical service life (switching cycles)
Mechanical service life (switching cycles)Mechanical service life (switching cycles)
● of the main contacts typical 100000
● of auxiliary contacts typical 100000
Electrical endurance (switching cycles)
Electrical endurance (switching cycles)
Electrical endurance (switching cycles)
Electrical endurance (switching cycles)Electrical endurance (switching cycles)
● typical 100000
Certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
Protection against electrical shock
Protection against electrical shock
Protection against electrical shock
Protection against electrical shockProtection against electrical shock finger-safe
Reference code acc. to DIN EN 81346-2
Reference code acc. to DIN EN 81346-2
Reference code acc. to DIN EN 81346-2
Reference code acc. to DIN EN 81346-2Reference code acc. to DIN EN 81346-2 Q
Ambient conditions
Installation altitude at height above sea level
Installation altitude at height above sea level
Installation altitude at height above sea level
Installation altitude at height above sea levelInstallation altitude at height above sea level
● maximum 2000m
Temperature compensation
Temperature compensation
Temperature compensation
Temperature compensationTemperature compensation -20...+60°C
Relative humidity during operation 10...95%
Main circuit
Number of poles for main current circuit
Number of poles for main current circuit
Number of poles for main current circuit
Number of poles for main current circuitNumber of poles for main current circuit 3
Adjustable pick-up value current of the current-
Adjustable pick-up value current of the current-
Adjustable pick-up value current of the current-
Adjustable pick-up value current of the current-Adjustable pick-up value current of the current-
dependent overload release
dependent overload release
dependent overload release
dependent overload releasedependent overload release
0.55...0.8A
Operating voltage
Operating voltage
Operating voltage
Operating voltageOperating voltage
● rated value 690V
● at AC-3 rated value maximum 690V
Operating frequency rated value
Operating frequency rated value
Operating frequency rated value
Operating frequency rated valueOperating frequency rated value 50...60Hz
Operating current rated value
Operating current rated value
Operating current rated value
Operating current rated valueOperating current rated value 0.8A
Operating current
Operating current
Operating current
Operating currentOperating current
● at AC-3
— at 400 V rated value 0.8A
Operating power
Operating power
Operating power
Operating powerOperating power
● at AC-3
— at 230 V rated value 120W
— at 400 V rated value 180W
— at 500 V rated value 250W
— at 690 V rated value 370W
Operating frequency
Operating frequency
Operating frequency
Operating frequencyOperating frequency
● at AC-3 maximum 151/h
Auxiliary circuit
Number of NC contacts for auxiliary contacts
Number of NC contacts for auxiliary contacts
Number of NC contacts for auxiliary contacts
Number of NC contacts for auxiliary contactsNumber of NC contacts for auxiliary contacts 0
Number of NO contacts for auxiliary contacts
Number of NO contacts for auxiliary contacts
Number of NO contacts for auxiliary contacts
Number of NO contacts for auxiliary contactsNumber of NO contacts for auxiliary contacts 0
Number of CO contacts
Number of CO contacts
Number of CO contacts
Number of CO contactsNumber of CO contacts
● for auxiliary contacts 0
3RV2011-0HA10 Subject to change without notice
Page 2/
8
06/07/2019 © Copyright Siemens


Produkt Specifikationer

Mærke: Sirius
Kategori: Afbryder
Model: 3RV2011-0HA10

Har du brug for hjælp?

Hvis du har brug for hjælp til Sirius 3RV2011-0HA10 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Afbryder Sirius Manualer

Sirius

Sirius 3RV2011-0HA10 Manual

20 November 2022

Afbryder Manualer

Nyeste Afbryder Manualer

Hager

Hager HED630H Manual

14 November 2024
Hager

Hager HED400H Manual

14 November 2024
ATen

ATen CE624-AT-G Manual

20 August 2024
Hager

Hager ADC913T Manual

22 Maj 2024
Hager

Hager LLD685 Manual

19 Maj 2024
Hager

Hager LLD004 Manual

17 Maj 2024