Læs gratis den danske manual til SurgeX SX-DS-158 (3 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 27 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 14 anmeldelser. Har du et spørgsmål om SurgeX SX-DS-158, eller vil du spørge andre brugere om produktet?
Side 1/3

SX- -158, SX- -208, SX- - i, SX- - i DS DS DS 1011 DS 1611
User Manual
© 2018 AMETEK Electronic Systems Protection | Technical Support 1- - -9712 | -Defender-Rack-Rev-A 800 645 UM

© 2018 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com 1
I. Product Overview
The SurgeX Defender Series are AC surge suppressors and power filters designed to be installed in a 19-inch/48.26
cm equipment rack. 120V and 240V models are available to match global power requirements.
Model
Voltage
Current
Input Plug
Output Receptacles
SX- - DS 158
120 V
15A
NEMA 5- 15P
8, 15RNEMA 5-
SX- - DS 208
120 V
20A
NEMA 5- 20P
2, NEMA 5-20R
6 NEMA 5- , 15R
SX- - i DS 1011
240 V
10A
IEC C14
11, IEC C13
SX- -16 i DS 11
240 V
16A
IEC C20
11, IEC C13
II. Installation
The Defender Series are designed to be installed in a 19-inch/48.26 cm equipment rack and require one unit (1-U) of
rack space. Use the four screws provided with the product to secure the rack ears to the rack rails. These screws can
be tightened by hand and do not require tools.
120V Models (SX- -158, SX- -208): Connect power to the unit by plugging the attached power cord into a DS DS
properly wired and grounded supply receptacle.
240V Models (SX- - , SX- - i): Connect power to the unit by plugging an appropriately rated 3 wire DS 1011 DS 1611
grounding type power cord into a properly wired and grounded supply receptacle. The socket-outlet shall be installed
near the equipment and shall be easily accessible.
Do not plug the unit into a relocatable power tap.
The maximum current rating of each individual receptacle, and of the unit as a whole, must not be exceeded:
Model
Total Maximum Current
Maximum Current Per Outlet
SX- - DS 158
15 A
15 A
SX- - DS 208
20 A
6 Outlets, 15A
2 Outlets, 20A
SX- - i DS 1011
10 A
10A
SX- -16 i DS 11
16 A
10A
Plug the equipment cords into the receptacles as needed.
III. Indicators
Located on the front panel is a green LED. System On
All models: When the LED is illuminated, there is AC power at the AC mains input to the product, and at System On
each of the product’s outlets.
SX- -158, SX- -208: When the DS DS System On LED is not illuminated, one of the following conditions is true:
• There is no power at AC mains input, or
• The supply receptacle is mis-wired, with the Line and Neutral conductors reversed, or
• The supply voltage is too high (> 180V ± 10V), or
• The input circuit breaker has tripped.
SX- - i, SX- - i: When the DS 1011 DS 1611 System On LED is not illuminated, one of the following conditions is true:
• There is no power at AC mains input, or
Produkt Specifikationer
Mærke: | SurgeX |
Kategori: | Ikke kategoriseret |
Model: | SX-DS-158 |
Har du brug for hjælp?
Hvis du har brug for hjælp til SurgeX SX-DS-158 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Ikke kategoriseret SurgeX Manualer
19 Juli 2025
11 December 2024
11 December 2024
10 December 2024
10 December 2024
10 December 2024
10 December 2024
26 August 2024
26 August 2024
26 August 2024
Ikke kategoriseret Manualer
- Graco
- Gamewright
- Ovente
- Rotho
- Transparent
- Proxxon
- Hobart
- Senco
- Primacoustic
- Fischer
- Freedor
- BISWIND
- Dynon Avionics
- Wampler
- Kaiser Nienhaus
Nyeste Ikke kategoriseret Manualer
2 August 2025
2 August 2025
2 August 2025
2 August 2025
2 August 2025
2 August 2025
2 August 2025
2 August 2025
2 August 2025
2 August 2025