Læs gratis den danske manual til Techly I-LIGHT-SNR11TY (4 sider) i kategorien Bevægelsesdetektor. Denne vejledning er vurderet som hjælpsom af 46 personer og har en gennemsnitlig bedømmelse på 4.7 stjerner ud af 23.5 anmeldelser. Har du et spørgsmål om Techly I-LIGHT-SNR11TY, eller vil du spørge andre brugere om produktet?
Side 1/4

INFRARED MOTION SENSOR
ATTENTION! Read the user manual completely and
carefully for proper installation and use. Keep this user
manual for future clarification.
SAFETY INSTRUCTIONS
• Thisproductisnotatoyandisnotmeantforchildren,becauseit
containssmallpartswhichcanbeswallowedandcaninjurewhen
used inappropriately!
•Donotuseanydamagedproductsorparts.
•Removethepackingmaterialsbecausetheymaybedangerous
forchildren.Thereisariskofincidentalsswallowingandinhalation
ofinsulatingmaterial.
•Donotmodifyorchangetheproductoritsaccessories:thiswill
haveeffectonthewarranty
•Ifdefects,mechanicaldamages,disturbancesorotherproblems
occur,whicharenotsolvablewiththismanual,takethedeviceout
ofworkimmediatelyandconsultyourdealer.
• This motion sensor isnotsuitable for use ascomponent of an
alarmsystem.Itmighttriggerfalsealarmsiftheinstallationplace
hasbeenchosenunfavourably.
INTENDED USE
This product is made for home useand it is not permitted using
this product in other ways than descripted in this manual. Use
the product only in dry interior rooms. If not attending to these
regulations and notes on safety, it might cause fatal accidents,
injuriesanddamagestopersonsandproperty.Themanufactureris
notliablefordamagestopersonsorpropertycausedbyimproper
installation,operationormaintenance,notdescribedinthismanual.
DESCRIPTION AND FUNCTION
Thisproductisaninfraredmotionsensorforindoorsandisspecified
asinstallationmaterial.Itreactstoheatradiation(infraredradiation)
ofmovingobjectsthatenterthedetection areaofthe sensor,eg.
peopleandanimals,etc.Thesensormust“see”theareawhichis
monitored.Thermal radiation propagates in a straightline, butis
stoppedbyglassorothersolidobjects.
FUNCTION:
Can identify day and night:Theconsumercanadjustworking
stateindifferentambientlight.Itcanworkinthedaytimeandat
nightwhenitisadjustedonthe“sun”position(max).Itcanwork
intheambientlightlessthan3LUXwhenitisadjustedonthe“3”
position(min).
SENS adjustable:Itcanbeadjustedaccordingtousinglocation.
Thedetectiondistanceofwallmountingcouldbe8mandceiling
mountingcouldbe6m.
Time-Delay is added continually:Whenitreceivesthesecond
inductionsignalswithinthefirst induction, itwillrestart totime
from the moment.
SPECIFICATION
Power Source 220-240V/AC
Detection Range 120°/360°
Power Frequency 50Hz
Detection Distance wall:Max.8m(<24°C)
ceiling:Max.6m(<24°C)
Ambient Light <3-2000LUX(adjustable)
Time Delay Min.10sec±3sec
Max.8min±2min
Working Temperature -20~+40°C
Working Humidity <93%RH
Rated Load Max.800W 200W
Power Consumption approx0.5W
Installation Height 1.8-2.5m(wallmounting)
2.2-4m(ceilingmounting)
Detection Moving Speed 0.6-1.5m/s
INSTALLATION ADVICE
As the detector responds to changes in temperature, avoid the
following situations:
Avoidpointingthedetectortowardsobjectswithhighlyreflective
surfaces,suchasmirrorsetc.
Avoidmountingthedetectornearheatsources,suchasheating
vents,airconditioningunits,lightetc.
Avoidpointingthedetectortowardsobjectsthatmaymoveinthe
wind,suchascurtains,tallplantsetc
ATTENTION! Only skilled
electricians may assemble
and disassemble the
housingoftheproduct.
ATTENTION! DANGER! Risk of life by electric shock! Avoid
contactingmainsvoltages!Turnoffthepowerofallcircuitsbefore
workingontheproduct!
AT T E N T I O N
• Warning. Danger of death
throughelectricshock!•Must
be installed by professional
electrician. • Disconnect
powersource.•Coverorshiedanyadjacentlivecomponents.•
Ensuredevicecannotbeswitchedon.•Checkpowersupplyis
disconnected.
AT T E N T I O N
D A N G E R
D A N G E R
GoodSensitivity PoorSensitivity
EN - 1
WWW.TECHLY.COM
INFRARED MOTION
SENSOR

SENSOR INFORMATION:
TEST:
Turn the LUX knob clockwise on the maximum(sun). Turnthe
TIMEknobanti-clockwiseontheminimum(10s)
Switchonthepower;thesensoranditsconnectedlampwillhave
nosignalatthebeginning.AfterWarm-up30sec,thesensorcan
startwork.Ifthesensorreceivestheinductionsignal,thelamp
willturnon.Whilethereisnoanotherinductionsignalanymore,
theload shouldstop working within10sec±3sec andthelamp
would turn off.
Turn LUX knob anti-clockwise on the minimum (moon). If the
ambientlightismorethan3LUX,thesensorwouldnotworkand
thelampstopworkingtoo.Iftheambientlightislessthan3LUX
(darkness), the sensor would work. Under no induction signal
condition,thesensorshouldstopworkingwithin10sec±3sec.
TIME: Adjustthelightingtime(10sto7min)
LUX:Adjustthephotosensitivity(3-2000Lx)
Note:whentestingindaylight,pleaseturnLUXknobto (SUN)
position,otherwisethesensorlampcouldnotwork!Ifthelampis
morethan60W,thedistancebetweenlampandsensorshouldbe
60cmatleast.
Motionsensorworks byday andnight.Fordaylightuse, setLUX
knobtomaximum(SUN)forcorrectwork.
SOME PROBLEM AND SOLVED WAY
The product does not work:
a.Please check if the connection of power source and load is
correct.
b.Pleasecheckfunctionofthelampandswitchonmainfuseafter
complete installation.
c.Please check if the settings of working light correspond to
ambientlight.
The sensitivity is poor:
a.Pleaseremoveobjectsoutfromthedetectionarea.
b.Pleasecheckiftheambienttemperatureistoohigh.
c.Please checkif the induction signal source is in the detection
field.
d.Pleasecheckiftheinstallationheightcorrespondstotheheight
required in the instruction.
The lighting time is not compliance with needed:
a.If the sensor can’t shut off thelamp, please check if the time
delayissettomaximumposition
b.Pleaseadjustthelightingtimeasyouneed.
WARRANTY
No guarantee or liability can be accepted for any changes and
modifications of the productor damage causeddue to incorrect
use of this product.
CONNECTION
•Switchoffthemainfuse.
•Checkwithavoltagetestertobesurealllinesarereallystress-
free.
• Installthesensortowallorceilingusingtheinstallationmaterial
includedintothepackage(seebelowtheinstallationdiagram).At
this,attendtothecablelocationanditsalignment.Alsoattendto
thedetectionareaandmaxdistance.
• Connectthe powerand theload according to theconnection-
wirediagrambelow.
Testthesensorasbelowindicated.
CONNECTION-WIRE DIAGRAM:
WiththeCEsign,Techly
® ensures that the product is conformed to
thebasicEuropeanstandardsanddirectives.
In accordance with the WEEE regulation, electrical and
electronicequipmentmustnotbedisposedofwithhousehold
waste. It means that used electrical and electronic products
shouldnotbemixedwithgeneralhouseholdwaste.Thereisa
separate collections system for these products.
Heightofinstallation:2.2-4m DetectionDistance:Max.6m
EN - 2
WWW.TECHLY.COM
INFRARED MOTION
SENSOR
Produkt Specifikationer
Mærke: | Techly |
Kategori: | Bevægelsesdetektor |
Model: | I-LIGHT-SNR11TY |
Kode for international beskyttelse (IP): | IP20 |
Bredde: | 36.8 mm |
Højde: | 25.5 mm |
Vægt: | 69 g |
Antal pr. pakke: | 1 stk |
Brugervejledning: | Ja |
Produktfarve: | Hvid |
Relativ luftfugtighed ved drift (H-H): | 0 - 93 % |
Strømforbrug (typisk): | 0.5 W |
Driftstemperatur (T-T): | -20 - 40 °C |
Forbindelsesteknologi: | Ledningsført |
Strømforbrug (maks.): | 800 W |
Monteringstype: | Loft/væg |
Indgangsspænding: | 220 - 240 V |
Sensortype: | Passiv infrarød (PIR) sensor |
Indgangsfrekvens: | 50 Hz |
Opdagelsesafstand: | 6 m |
Lys sensitivitet: | 2000 Lux |
Installationshøjde (min.): | 1.8 m |
Installationshøjde (maks.): | 4 m |
Registreringsvinkel: | 360 ° |
Registrering af lysstyrke: | Ja |
Justerbar lysintensitet: | Ja |
Har du brug for hjælp?
Hvis du har brug for hjælp til Techly I-LIGHT-SNR11TY stil et spørgsmål nedenfor, og andre brugere vil svare dig
Bevægelsesdetektor Techly Manualer
27 Juli 2024
27 Juli 2024
Bevægelsesdetektor Manualer
- Abus
- Gira
- Satel
- Konyks
- ALC
- Brennenstuhl
- Yale
- Aqua Joe
- Pentatech
- Elgato
- Goobay
- Intertechno
- KlikaanKlikuit
- Plugwise
- Velleman
Nyeste Bevægelsesdetektor Manualer
17 Juli 2025
11 Juli 2025
9 Juli 2025
8 Juli 2025
8 Juli 2025
7 Juli 2025
7 Juli 2025
7 Juli 2025
7 Juli 2025
6 Juli 2025