Theben RAMSES 856 top2 OT Manual

Theben Termostat RAMSES 856 top2 OT

Læs gratis den danske manual til Theben RAMSES 856 top2 OT (20 sider) i kategorien Termostat. Denne vejledning er vurderet som hjælpsom af 60 personer og har en gennemsnitlig bedømmelse på 3.8 stjerner ud af 30.5 anmeldelser. Har du et spørgsmål om Theben RAMSES 856 top2 OT, eller vil du spørge andre brugere om produktet?

Side 1/20
RAMSES
RAMSES 856 top2 OT
Heating controller
8569132
309560 04
GB
RAMSES 856 top2
Installation and
operating guide
OT Box RAMSES top2 OT Standard box
F
NL E I
GB
D
Proper use
The heating controller RAMSES 856 top OT consists of the OT-Box
RAMSES top2 OT as well as the room thermostat RAMSES 850 top2
OT, which transmits the values (target/actual values) via the Open-
Therm bus. The 7-channel regulator regulates 2 heating circuits
with the required circulation pumps and temperature sensors. In ad-
dition, the domestic hot water circulation is maximised via program
control with optional legionella protection function. The range of
functions can be extended via connection of 2 OT boxes.
The device is intended for wall installation in the boiler room
Corresponds to Type 1 B in accordance with IEC/EN 60730-1
The entire system serves the purpose of digital heating
regulation for time-dependent monitoring and control of room
temperature (by means of circulation pumps, burner and/or
motor mixing valve)
It is used in dry rooms with normal levels of domestic cleanliness
The controller is suitable only for the Heating-
systems listed. For use in connection with other
systems, contact the service department of Theben AG
Accessories: optional: RAMSES 850 top2 OT ( (8509132),
feed temperature sensor (9070371), plunge sensor (9070379),
floor sensor (9070321), external temperature sensor (9070459),
additional OT box for system 5 (standard box 9070712)
Disposal
Dispose of equipment in an environmentally sound manner
Contents
Proper use 2
Disposal 2
Safety advice 3
Installation and dismantling 3
Connection 4
Terminal layout 5
Description 6
Start-up with RAMSES 850 top2 OT 7
Set TSP parameters (Transparent Slave Parameters) 8
Set heating curve of second heating circuit on controller 8
Systems/Applications 1–5 9
System 1 10
System 2 11
System 3 12
System 4 13
System 5 comfort box 14
Switch chimney sweep function on/off 17
Operating hours counter 17
Connect USB/GSM modem 17
Error messages 18
Technical data 19
Service address/Hotline 20
22


Produkt Specifikationer

Mærke: Theben
Kategori: Termostat
Model: RAMSES 856 top2 OT

Har du brug for hjælp?

Hvis du har brug for hjælp til Theben RAMSES 856 top2 OT stil et spørgsmål nedenfor, og andre brugere vil svare dig