Tommee Tippee Closer to Nature Manual

Tommee Tippee Baby-produkt Closer to Nature

Læs gratis den danske manual til Tommee Tippee Closer to Nature (4 sider) i kategorien Baby-produkt. Denne vejledning er vurderet som hjælpsom af 9 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 5 anmeldelser. Har du et spørgsmål om Tommee Tippee Closer to Nature, eller vil du spørge andre brugere om produktet?

Side 1/4
electric
breast pump
INSTRUCTIONS FOR USE
5
3
9
7
6
4
8
18
17
1
2
21
22
20
19
10
11
14
13
12
16
15
9 12 21
For hygiene reasons this product cannot be returned once opened unless faulty.
Please read and retain this information for future reference.
The intended use of the Tommee Tippee Electric Breast Pump is to express milk from the breast of lactating women.
Researched and developed by specialists and breastfeeding experts to express milk for storage and later use.
PARTS GUIDE
DISASSEMBLING THE ELECTRIC BREAST PUMP
1. Unscrew bottle from lower pump body.
2. Pull off valve.
3. Pull air tube from upper pump body and motor unit.
4. Press release tabs to release upper pump body and pull apart.
5. Pull out diaphragm cap and diaphragm.
6. Pull horn from lower pump body.
IT IS NOT ESSENTIAL TO TAKE THE SILICONE INSERT OUT OF THE HORN FOR CLEANING unless milk or dirt has become trapped inside. If so, unclip lip
from cup and pull apart.
CLEANING, STERILISING AND MAINTENANCE
Before use ensure the breast pump has been disassembled, washed and sterilised.
The parts to be sterilised are :
Silicone insert, horn, upper pump body, lower pump body, diaphragm, diaphragm cap, valve, bottle, horn hygiene cover, and milk storage lid or
milk storage pods if required. These components are suitable for sterilisation by steam (electric and microwave), boiling, or cold
water tablet/ liquid solution. Follow the steriliser manufacturer’s instructions.
Do not sterilise:
Air tube, motor unit and adaptor. Wipe clean only with a damp cloth.
Always wash the product immediately after use to remove milk residue.
Wash all products to be sterilised in warm soapy water and rinse in clean water or use a dishwasher.
Do not clean with solvents or harsh chemicals.
3 64 8
12 7 1917 18
1. Silicone insert
2. Horn
3. Upper pump body
4. Lower pump body
5. Release tabs
6. Diaphragm
7. Diaphragm cap
8. Valve
9. Air tube
10. Air tube socket
11. Mains adaptor socket
12. Motor
13. On/off button
14. Low expression button/light indicator
15. Medium expression button/light indicator
16. High expression button/light indicator
17. 150ml bottle
18. Bottle stand & horn hygiene cover
19. 60ml milk storage pot
20. Breast pads
21. Mains adaptor
22. Steriliser box
22
1. On/o button to promote milk let down
2. Low expression button
3. Medium expression button
4. •• High expression button
2
3
4
1
Do not allow product to come into contact with oil based foods (e.g. oil/ tomato based sauces) as staining will occur.
Inspect the air tube before and after each use for condensation. Allow to air dry before next use.
To clean the valve, rub gently between your fingers in warm soapy water – do not insert objects as damage could result.
Routine maintenance includes cleaning. No other servicing is required.
ASSEMBLING THE ELECTRIC BREAST PUMP
1. Wash your hands thoroughly before handling the pump.
Wash and sterilise your breast pump before using. Follow instructions in section for CLEANING, STERILISING AND MAINTENANCE.
2. Make sure the silicone insert is securely attached. Clip lip over end of horn first, then push tube through funnel, ensuring lip is fully clipped over the
other side also.
3. Push horn onto the lower pump body as far as it will go.
4. Push diaphragm down into lower pump body as far as it will go and push diaphragm cap over the top as far as it will go until it is sealed.
5. Push upper pump body and lower pump body together. They will click into place.
6. Push valve onto lower pump body.
7. It is possible for the valve to seal closed during storage & cleaning. Before each use remember to clean & squeeze the valve to open.
8. Screw bottle onto lower pump body.
9. Connect air tube onto upper pump body and the air tube socket of the motor unit. This is on the RIGHT of the two sockets on the motor unit.
10. Plug the electric adaptor into the electric adaptor socket of the motor unit. This is on the LEFT.
11. Plug the electric adaptor into the mains power supply.
BATTERY OPERATION
1. To install batteries, disconnect the air tube and mains adaptor.
2. Push the clip of the battery compartment towards centre of motor unit whilst pulling upwards. Remove the cover.
3. Insert batteries as indicated inside the battery compartment and push the cover back into place until it snaps shut.
4. Batteries are to be inserted with the correct polarity. Ensure that the + and – ends of the batteries are positioned correctly.
Requires 4AA batteries (sold separately). DO NOT USE RECHARGEABLE BATTERIES. The use of rechargeable batteries could cause your breast pump to
malfunction and will void the warranty. Non-rechargeable batteries are not to be recharged. Different types of batteries or new and used batteries are
not to be mixed. Only batteries of the same or equivalent type as recommended are to be used. Exhausted batteries are to be removed from the breast
pump. Batteries should always be removed or replaced by an adult. Keep away from children. Remove batteries if the electric breast pump will not be
used for some time. Help the environment by disposing of your product responsibly. The wheelie bin symbols indicate the product and batteries must
not be disposed of in the domestic waste as they contain substances which can be damaging to the environment and health. Please use designated
collection points or recycling facilities when disposing of the item or batteries.
INFORMATION ON THE DISPOSAL FOR WASTE ELECTRICAL & ELECTRONIC EQUIPMENT (WEEE)
This symbol on the products and accompanying documents means that used electrical and electronic products should not be mixed
with general household waste.
For proper disposal for treatment, recovery and recycling, please take these products to designated collection points where they will
be accepted on a free of charge basis. In some countries you may be able to return your products to your local retailer upon the
purchase of a new product. Disposing of this correctly will help you save valuable resources and prevent any possible effects on
human health and the environment, which could otherwise arise from inappropriate waste handling.
Please contact you local authority for further details of your nearest collection point for WEEE.
Penalties may be applicable for the incorrect disposal of this product in accordance with national legislation.
USING THE ELECTRIC BREAST PUMP
1. Ensure that the breast pump has been cleaned and sterilised. Wash your hands before touching the breast pump or your breasts and avoid
touching inside the breast pump or the storage pot. Find a comfortable chair where you can relax
2. Hold the pump in whichever hand is most comfortable.
3. Place the silicone insert of the horn over your breast, so that it creates a seal all the way round. IF AIR CAN GET IN THERE WILL BE LOW OR NO
SUCTION.
4. Press the on/off button to promote milk let-down. This let-down setting is a gentle rhythm to get your milk flowing.
5. IMPORTANT: Sit upright and do not tilt the bottle while pumping, it should be kept upright at all times to avoid milk flowing back up through the air
tube. If this happens you must turn the breast pump off immediately as it could damage the motor. Read HELPFUL ADVICE for further information
WEE/JC0045SY
1
21 3 5
6 8
4
109 117


Produkt Specifikationer

Mærke: Tommee Tippee
Kategori: Baby-produkt
Model: Closer to Nature
Produktfarve: Transparent,White
Anbefalet alder (min): 0 måned(er)
Indeholder ikke: Bisphenol A (BPA)
Nippel materiale: Silikone
Flaske kapacitet: 260 ml
Antal nipler inkluderet: 6
Antal flasker inkluderet: 6
Gennemløbshastighed: Langsom flow

Har du brug for hjælp?

Hvis du har brug for hjælp til Tommee Tippee Closer to Nature stil et spørgsmål nedenfor, og andre brugere vil svare dig