Tripp Lite Internet650U1 Manual


Læs gratis den danske manual til Tripp Lite Internet650U1 (29 sider) i kategorien Uafbrydelig strømforsyning (UPS). Denne vejledning er vurderet som hjælpsom af 22 personer og har en gennemsnitlig bedømmelse på 4.7 stjerner ud af 11.5 anmeldelser. Har du et spørgsmål om Tripp Lite Internet650U1, eller vil du spørge andre brugere om produktet?

Side 1/29
1
Standby UPS Systems
Models:
BC350, BC450, BC500, INTERNET350U, INTERNET350SER,
INTERNET550SER, INTERNET550U, INTERNET600U,
INTERNET650U1
(Series Numbers: AG-030D, AG-030E, AG-030F, AG-0311,
AG-0312, AG-87AF, AG-0305, AG-0307, AG-0394)
Important Safety Instructions 2
............
Quick Installation 4
..............................
Optional Installation 5
..........................
Basic Operation 5
................................
UPS On/Off 5
...................................
LED Indicator 6
................................
Features 7
...........................................
UPS Features 7
................................
Battery Replacement 8
.......................
Storage and Service 9
.........................
Product Registration and................... 9
Regulatory Compliance
Español........................................... 11
Français 21
..........................................
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2018 Tripp Lite. All rights reserved.
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an ISOBAR6ULTRA
surge protector—a $100 value!
www.tripplite.com/warranty
18-11-058-933864.indb 1 11/20/2018 8:28:42 AM
2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the
installation, operation and storage of this product. Failure to heed these warnings
may affect the warranty.
UPS Location Warnings
Install your UPS indoors, away from excess moisture or heat, conductive contaminants,
dust or direct sunlight.
For best performance, keep the indoor temperature between 32º F and 104º F (0º C and
40º C).
Leave adequate space around all sides of the UPS for proper ventilation.
Only set the UPS upright on a sturdy flat surface.
UPS Connection Warnings
Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into
itself; this will damage the UPS.
Do not modify the UPS plug, and do not use an adapter that would eliminate the UPS
ground connection.
Do not use extension cords to connect the UPS to an AC outlet.
If the UPS receives power from a motor-powered AC generator, the generator must provide
clean, filtered, computer-grade output.
The mains socket outlet that supplies the UPS should be easily accessible and located near
the UPS.
Equipment Connection Warnings
Install in accordance with National Electrical Code standards ANSI/NFPA
70 and Canadian Electrical Code, Part I, C22.1.
Short-circuit backup protection and overcurrent protection is provided by
the building installation.
To reduce the risk of fire, connect only to a circuit provided branch circuit
overcurrent protection in accordance with the National Electrical Code,
ANSI/NFPA 70 and the Canadian Electrical Code, Part I, C22.1. The plug on
the power supply cord is intended to serve as the disconnect device. Be
sure that the socket-outlet is installed near the equipment and is made
easily accessible.
Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended.
Do not connect surge protectors or extension cords to the output of your UPS. This might
damage the UPS and may affect the surge protector and UPS warranties.
Connect the UPS to an outlet that is adequately protected against excess currents, short
circuits and earth faults as part of the building installation.
Important Safety Instructions
18-11-058-933864.indb 2 11/20/2018 8:28:42 AM


Produkt Specifikationer

Mærke: Tripp Lite
Kategori: Uafbrydelig strømforsyning (UPS)
Model: Internet650U1
Bredde: 110 mm
Dybde: 184.9 mm
Højde: 104.9 mm
Vægt: 1800 g
Brugervejledning: Ja
Produktfarve: Sort
Pakkevægt: 2220 g
Pakkedybde: 275.8 mm
Pakkebredde: 144 mm
Pakkehøjde: 180.3 mm
USB-port: Ja
Formfaktor: Kompakt
Opbevaringstemperatur (T-T): -15 - 45 °C
Relativ luftfugtighed ved drift (H-H): 0 - 90 %
Relativ luftfugtighed ved opbevaring (H-H): 0 - 90 %
Ethernet LAN-porte (RJ-45): 2
Antal USB 2.0-porte: 2
Driftstemperatur (T-T): 0 - 40 °C
Husmateriale: Acrylonitrilbutadienstyren
Kabler inkluderet: USB kabel
Udgangseffekt: 330 W
LED-indikatorer: Ja
Kabellængde: 1.5 m
Bæredygtighedscertifikater: RoHS
Driftshøjde: 0 - 3000 m
Hovedkassen højde (udvendigt): 393.7 mm
Hovedkassens længde (udvendigt): 591.8 mm
Hovedkassens bruttovægt (udvendigt): 18460 g
Hovedkassens bredde (udvendigt): 286 mm
Oprindelsesland: Vietnam
Produkter pr. hovedkasse (udvendigt): 8 stk
Indgangsfrekvens: 50/60 Hz
Hovedkasse (udvendig) GTIN (EAN/UPC): 10037332211054
Lydalarmer: Ja
Strømstik: NEMA 5-15P
AC udgange, antal: 8 AC stikkontakt(er)
AC stikkontakt typer: NEMA 5-15R
Overspænding energivurdering: 316 J
Indgående driftsspænding (maks.): 120 V
Output strømkapacitet (VA): 0.65 kVA
Indgående driftsspænding (min.): 120 V
Udgangs driftsspænding (min.): 110 V
Udgangs driftsspænding (maks.): 120 V
UPS topologi: Standby (offline)
Beskyttelsesfunktioner mod strømstød: Digital Subscriber Line (DSL),Network,Telephone
Strøm (maks.): 6 A
Beskyttelse ved overspænding: Ja
Bølgeform: Sine
Hørbare alarmtilstande: Battery replacement,Fault,Low battery alarm,Overload alarm
Typisk backup tid ved halv styrke: 4.5 min.
Koldstart: Ja
Uddgående frekvens: 50/60 Hz
EMI/RFI støjfiltrering: Ja
Antal indgående faser: 1
Regulering af udgangsspænding: ±5% %