Læs gratis den danske manual til Tripp Lite PowerVerter APSX4048SW (48 sider) i kategorien Accu. Denne vejledning er vurderet som hjælpsom af 23 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 12 anmeldelser. Har du et spørgsmål om Tripp Lite PowerVerter APSX4048SW, eller vil du spørge andre brugere om produktet?

Side 1/48
1
Owner’s Manual
Sine Wave DC-to-AC Inverter/Charger
Model: APSX4048SW
48 VDC to 230 VAC
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2014 Tripp Lite.
Table of Contents
Important Safety Instructions 2
1. Overview & Features 3
1.1 Overview 3
1.2 Front Panel Controls, LCD Screen 3
and LED Indicators
1.3 Optional Features 4
2. Battery Charger 4
2.1 Mode of Operation 4
2.2 Transfer Switching Speed 4
3. Battery Installation 4
and Maintenance
3.1 Select Battery Type 4
3.2 Monthly Maintenance 6
3.3 Battery Installation 6
3.4 Battery Connection 6
4. Inverter/Charger Single-Phase 9
Installation
4.1 Installation 9
4.2 Installation Diagrams and Charts 9
4.3 Installation and Start-Up 10
4.4 Single-Phase Parallel Stacking 11
Installation and Start-Up
5. Inverter/Charger 3-Phase 13
Parallel Installation
5.1 Installation 13
5.2 Installation Diagrams and Charts 13
5.3 Installation and Start-Up 14
6. Operation 16
6.1 Modes of Operation 16
(Single and 3-Phase)
6.2 Settings and Parameters 18
6.3 Single-Phase Parallel Operation 20
6.4 3-Phase Parallel Operation 21
7. Technical Specifications 22
8. Troubleshooting 22
9. Service 23
Русский 24
PROTECT YOUR INVESTMENT!
Register your product for quicker service and ultimate peace of mind.
You could also win an ISOBAR6ULTRA surge protector—a $50 value!
www.tripplite.com/warranty
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS!
This manual contains important instructions and warnings that should be followed during the installation,
operation and storage of all Tripp Lite Inverter/Chargers.
Location Warnings
Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously
inhibit the unit’s internal cooling, eventually causing product damage not covered under warranty.
• Install your Inverter/Charger in a location or compartment that minimizes exposure to heat, dust, direct sunlight and
moisture. Flooding the unit with water will cause it to short-circuit and could cause personal injury due to electric shock.
• For proper ventilation, allow a minimum 2 inches of clearance at front and back of the Inverter/Charger. To avoid overheating
the Inverter, the compartment that houses the Inverter/Charger must be properly ventilated with adequate outside air flow.
The heavier the load of connected equipment, the more heat will be generated by the unit.
• Do not install the Inverter/Charger near magnetic storage media, as this may result in data corruption.
• Do not install the Inverter/Charger near flammable materials, fuel or chemicals.
Battery Connection Warnings
• Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type.
• Because explosive hydrogen gas can accumulate near batteries if they are not well ventilated, do not install batteries in a
“dead air” compartment. The battery compartment should have some ventilation to outside air.
• Sparks may result during final battery connection. Always observe proper polarity as batteries are connected.
• Do not allow objects to contact the DC input terminals. Do not short or bridge these terminals together. Serious personal
injury or property damage could result.
Ground Connection Warnings
Safe operation requires connecting the Inverter/Charger’s Main Ground Terminal directly to the frame of the vehicle or
earth ground.
Equipment Connection Warnings
• Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause
the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not
use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
• You may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to the
output of the Inverter/Charger.
• User must supply proper protection for wire openings in unit panels.
Operation Warnings
• Your Inverter/Charger does not require routine maintenance.
• Potentially lethal voltages exist within the Inverter/Charger as long as the battery supply is connected. During any service
work, the battery supply should therefore be disconnected.
• Do not connect or disconnect batteries while the Inverter/Charger is operating from the battery supply. Dangerous arcing may
result.