UPG UB1250 Manual
Læs nedenfor 📖 manual på dansk for UPG UB1250 (2 sider) i kategorien Batteri. Denne guide var nyttig for 3 personer og blev bedømt med 4.4 stjerner i gennemsnit af 2 brugere
Side 1/2

Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe operation
in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certied. U.L. recognized under le number
MH 20567.
L: 3.54 in (90.0 mm)
W: 2.76 in (70.1 mm)
H: 3.98 in (101 mm)
TH: 4.21 in (107 mm)
Tolerances are +/- 0.04 in. (+/- 1mm)
and +/- 0.08 in. (+/- 2mm) for height
dimensions. All data subject to
change without notice.
Nominal Voltage
Nominal Capacity
20-hr. (0.25A)
10-hr. (0.46A)
5-hr. (0.85A)
1-hr. (3.00A)
Approximate Weight
Internal Resistance (approx.)
Shelf Life (% of normal capacity at 68º F (20º C)
3 Months 6 Months 12 Months
12 volts
5.00 Ah
1.5 A or smaller
14.6 - 14.8 V
77º F (25º C)
4.65 Ah
4.25 Ah
3.00 Ah
3.09 lbs (1.4 kgs)
32m
91% 83% 64%
Charge Method (Constant Voltage)
Cycle Use
Float Use
Initial Current
Control Voltage
13.6 - 13.8 V
Control Voltage
(Repeating Use)
Specification
Physical Dimensions: in (mm)
Terminals
Sealed Lead-Acid Battery
UPG No. D5777
Maintenance-Free
UB1250
3.98 (101)
4.21 (107)
2.76 (70.1)
3.54 (90.0)
Temperature Dependancy of Capacity
104 F (40 C) 77 F (25 C)
(20 hour rate)
102% 100% 85%
32 F (0 C) 5 F (-15 C)
65%
AGM Operational Temperature
AGM Storage Temperature
(0 C to 40 C)32 F to 104 F
5 F to 113 F
5 F to 104 F
(-15 C to 45 C)
Charge
Discharge
(-15 C to 40 C)
Discharge Characteristics
(Minute) (Hour)
Discharge time
Cell voltage (V/Cell)
Discharge Time vs. Discharge Current
Discharge Current = CA X Nominal Capacity
(Minute) (Hour)
Duration of Discharge
488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 sales@upgi.com
www.upgi.com
All specifications subject to change without notice.
J2020-1
Due to continuous improvements to our products, product may vary slightly from depiction.
Copyright 2020 Universal Power Group, Inc. All rights reserved.
6.4 mm
0.25 in
8.2 mm
0.32 in
.8 mm
0.03 in
7.9 mm
0.31in

Charge Voltage(V/Cell)
Application
Temperature Set Point Allowable Range
Max.Charge Current
Cycle Use
25
(77 )
2.45 2.40~2.50
Standby
25
(77 )
2.30
0.3C
Final Discharge
Voltage V/Cell
1.75 1.70 1.60 1.30
Discharge
Current(A)
0.2C>(A) 0.2C<(A)<0.5C 0.5C<(A)<1.0C (A)>1.0C
Charge Current & Final Discharge Voltage
Cycle Life vs Depth of DischargeShelf Life & Storage
Eect of Temperature on CapacityOpen Circuit Voltage vs Residual Capacity
UPG No. D5777
Maintenance-Free
UB1250
2.27~2.3
488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 sales@upgi.com
www.upgi.com
Let UPG Power Your Life.
Produkt Specifikationer
Mærke: | UPG |
Kategori: | Batteri |
Model: | UB1250 |
Har du brug for hjælp?
Hvis du har brug for hjælp til UPG UB1250 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Batteri UPG Manualer

7 Juni 2025

7 Juni 2025

7 Juni 2025

6 Juni 2025
Batteri Manualer
- Batteri Elbro
- Batteri APsystems
- Batteri Hama
- Batteri Nikon
- Batteri Hedbox
- Batteri Cortina
- Batteri TOA
- Batteri Carat
- Batteri Powerworks
- Batteri Ozito
- Batteri Anova
- Batteri Powerfix
- Batteri Bosch
- Batteri DJI
- Batteri Vetus
Nyeste Batteri Manualer

7 Juni 2025

6 April 2025

6 April 2025

3 April 2025

3 April 2025

3 April 2025

3 April 2025

3 April 2025

3 April 2025

2 April 2025