Velleman VTBAL6 Manual


Læs gratis den danske manual til Velleman VTBAL6 (16 sider) i kategorien Køkkenvægt. Denne vejledning er vurderet som hjælpsom af 42 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 21.5 anmeldelser. Har du et spørgsmål om Velleman VTBAL6, eller vil du spørge andre brugere om produktet?

Side 1/16
VTBAL6
COUNTING SCALES
TELWEEGSCHAAL
BALANCE DE COMPTAGE
BALANZA CUENTAPIEZAS
ZÄHLWAAGE
USER MANUAL
GEBRUIKERSHANDLEIDING
NOTICE D’EMPLOI
MANUAL DEL USUARIO
BEDIENUNGSHANDLEITUNG
VTBAL6_v3 VELLEMAN
2
VTBAL6 – COUNTING SCALES
1. Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment.
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling.
This device should be returned to your distributor or to a local recycling service.
Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Velleman! Please read the manual thoroughly before bringing this device into service. If the device was damaged in
transit, do not install or use it and contact your dealer.
2. Technical Specifications
Capacity 5kg/12lb
Display Resolution 6.0000kg x 0.0005kg/13.2280lb x 0.0010lb
Counting Range 0 ~ 16777216
Tare Range 0 ~ 100% FS
Zero Range power-on zero range ± 5% FS
Min. Input Piece Weight 0.5g/0.0002lb
Operating Temperature 15°C ~ 35°C
Power Supply 220VAC/12VDC PSU + internal 6V/4Ah rechargeable battery (both incl.)
Power Consumption < 120mA at lowest brightness setting (200mA at default setting)
Dimensions 110 x 290 x 330mm
Spare PSU order code PS1205R
Spare Battery order code WP4-6
Unit Conversion 1lb = 0.45359237kg, 1kg = 2.20462262lb
3. Setting up Your Scales
Place the scales on a stable and horizontal surface where it is out of the sunlight and protected against extreme temperatures and
temperature changes, humidity, fumes, dust, draughts and electromagnetic fields. Turn the adjustable feet until the scales are level.
Insert the battery into the scales minding the polarity. Connect the scales to the PSU and insert the PSU into the mains.
4. Operation
4.1. Key Description
Numeric keypad
Clear the entered data (in input mode) or exit input mode after
clearing data
Confirm and save the entered data (in input mode) or confirm
operation (all other modes)
Zero the scales – range is power-on zero point ± 5% - proper
power-on zero point is calibration zero point ± 10% of FS
Tare function – tare range is 0 ~ 100% of FS
Totalising function
Choose the current weighing unit (kg or lb) or piece weighing unit
(g or lb)
Input the piece weight
Input the upper limit
Input the lower limit
On/off key or exit key when in auto off setting mode and calibration
mode


Produkt Specifikationer

Mærke: Velleman
Kategori: Køkkenvægt
Model: VTBAL6

Har du brug for hjælp?

Hvis du har brug for hjælp til Velleman VTBAL6 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Køkkenvægt Velleman Manualer

Velleman

Velleman VTBAL6 Manual

24 Juli 2024

Køkkenvægt Manualer

Nyeste Køkkenvægt Manualer