Læs gratis den danske manual til Vemer LPG Sensor (1 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 20 personer og har en gennemsnitlig bedømmelse på 3.5 stjerner ud af 10.5 anmeldelser. Har du et spørgsmål om Vemer LPG Sensor, eller vil du spørge andre brugere om produktet?

Side 1/1
V3IS00462-010
CH4 Sensor CO Sensor LPG Sensor, and areprobesforthedetectionof
methanegas,carbonmonoxideandLPGtobeconnectedtoSRG and SRG.4
controlunitstocreatesystemsfordetectinggasinareassuchasboilerrooms,
warehouses,etc.
It is wall-mounted in a vertical position using screws and plastic plugs.
SAFETY WARNINGS
During installation and operation of the instrument, comply with the
following instructions:
1) The device must be installed by a competent person
2) Before removing the cover, make sure that power is NOT provided to
the device
3) Before accessing the terminals, make sure that the electrical leads are
not live
4) Install the detector in the correct position (see “Installation”)
5) Do not power on the device if any part of it is damaged
Code Model Description
VE205100 CH4SENSOR Methanedetectionsensor
VE206900 LPG SENSOR LPG sensor
VE207700 CO SENSOR Carbonmonoxidesensor
TECHNICAL CHARACTERISTICS
• Powersupply:fromthecontrolunitSRGorSRG.4
 −Currentinput(at6.5V):40mA
 −Connection:terminalsof2.5mm2C(common),S(signal),A(powersupply)
• Modelsandcalibration:
 −Methanegas:CH4Sensor,(default)10%LIEofmethane
 −LPG:LPGSensor,(default)12%LIEofisobutene
 −Carbonmonoxide:COSensor,(default)200ppmofcarbonmonoxide
• Max.lengthofconnection:50m
• Container:inself-extinguishingplasticmaterial
• Fastenedtowallusingscrewsandplasticplugs
• Protection:IP30
• Operatingtemperature:0÷+50°C
• Humidity: 90%R.H.withoutcondensation
INSTALLATION
 LPG,COandCH4Sensorsaredesignedtobewall-mounted(vertically),using
screwsandplasticplugs.Toproceedwithinstallation,openthecontainerby
unscrewingthescrewlocatedonthelowerside.Makesurenottodamagethe
sensorandnottotouchthecalibrationdevices.
POSITIONING
 Thecorrectinstallationoftheprobeisessentialtoproperoperationofthe
system.Therefore,itmustbeinstalled:
• Inareaswithcirculationofnaturalair;
• Inareasthatarenotsubjecttodustordirtthatmayrenderthesensor
inoperative;
• Nearjetsofwater,intakegrilles,openings,etc.
• Atanadequatedistancefromusersofgassoastopreventthesystemfrom
interveningimproperlyduetofunctionalleakage.
 Also,positioningdependsonthetypeofgastobedetected,specically:
• CH4 Sensor: Methane gas – at top, about 20-30 cm from the ceiling
• LPG Sensor: LPG – at bottom, about 20-30 cm from the floor
• CO Sensor: carbon monoxide – about 1.5 m from the floor
 Fornewsystems,theprobemustbeinstalledaslateaspossible,sothattypical
constructionsiteactivitiesdonotdamagethedetector.
CONNECTIONS
 Normalelectricalcablescanbeusedforconnections.Inanycase,when
installationisinplacesthatarestronglyexposedtoelectromagnetic
disturbances,itisadvisabletouseshieldedcables.Thedetectionsystemmust
alwaysbeinoperation.Therefore,theelectricalpowersupplyofthedetector
mustnotincludeswitchesorotherdevicesthatmayaccidentallyshutitoff.The
averagelifespanoftheprobesis5yearsfromthedateofinstallation.Therefore,
attheendofthattimetheywillneedtobereplaced.
Note. Make sure you check operation at least once a year, and in any
case whenever there is an extended period of disuse or in the event of
replacement. Any tampering may compromise correct operation of the
system.
REFERENCE STANDARDS
CompliancewithCommunityDirectives:
2006/95/EC (lowvoltage)
89/336/EECmod.from andfrom92/31/EEC 93/68/EEC(E.M.C.)
isdeclaredwithreferencetothefollowingstandards:
EN 61779-4, EN 50270
User Manual
SENSORS FOR SRG/SRG.4 CONTROL UNITS
Read all the instructions carefully
Dimensions
Connection diagrams
119,0
75,3
75,3
36,0
CH4 SENSOR
C S A
C S A
SRG/SRG.4
Mod. CH4 SENSOR
Mod. LPG SENSOR
Mod. CO SENSOR


Produkt Specifikationer

Mærke: Vemer
Kategori: Ikke kategoriseret
Model: LPG Sensor

Har du brug for hjælp?

Hvis du har brug for hjælp til Vemer LPG Sensor stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Vemer Manualer

Vemer

Vemer TCR Manual

2 Oktober 2024
Vemer

Vemer Set PC RF8 Manual

1 Oktober 2024
Vemer

Vemer ADR-D Vision Manual

22 September 2024
Vemer

Vemer ES Manual

10 September 2024
Vemer

Vemer Thalos RF Manual

3 September 2024
Vemer

Vemer VE 502E Manual

1 September 2024
Vemer

Vemer VE LAN Manual

10 August 2024
Vemer

Vemer LCR048 Manual

10 August 2024
Vemer

Vemer PSR400 Manual

8 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Rival

Rival CN753-W Manual

15 Juni 2025
Acopa

Acopa 553WSMKE Manual

15 Juni 2025
Atosa

Atosa RDCS-35 Manual

15 Juni 2025
Gourmia

Gourmia GAF692 Manual

15 Juni 2025
Taylor

Taylor 5315856 Manual

15 Juni 2025
Watts

Watts LF8B Manual

15 Juni 2025
Watts

Watts PLT-5 Manual

15 Juni 2025
ToiToiKids

ToiToiKids Fay Manual

15 Juni 2025
Aiphone

Aiphone JP-8Z Manual

15 Juni 2025