Wilbur Curtis Alpha5Gt Manual


Læs gratis den danske manual til Wilbur Curtis Alpha5Gt (8 sider) i kategorien Kaffemaskine. Denne vejledning er vurderet som hjælpsom af 78 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 39.5 anmeldelser. Har du et spørgsmål om Wilbur Curtis Alpha5Gt, eller vil du spørge andre brugere om produktet?

Side 1/8
1
Models Included
•ALPHA1GT
•ALPHA2GT
•ALPHA2GTW
•ALPHA3GT
•ALPHA3GTR
•ALPHA3GTL
•ALPHA4GT
•ALPHA5GT
•ALPHA5GTR
•ALPHA5GTL
•ALPHA6GT
•ALPHA6GTN
connect this brewer to hot
water.Theinletvalveis
not rated for hot water.
CAUTION:Pleaseuse
this setup procedure
before attempting to use
this brewer. Failure to follow the
instructions can result in injury or the
voidingofthewarranty.
ISO9001REGISTERED
C
Important Safeguards/Conventions
Service Manual, Alpha G3 - Decanter Brewer
For the Latest speciFications and inFormation go to www.wiLburcurtis.com
This appliance is designed for commercial use. Any servicing other than cleaning and maintenance should be performed by an autho-
rized Wilbur Curtis service center.
•DoNOTimmersetheunitinwateroranyotherliquid
•Toreducetheriskofreorelectricshock,doNOTopentoporrearpanel.Nouserserviceablepartsinside.Repairshould
be done only by authorized service personnel.
•Keephandsandotheritemsawayfromhotpartsofunitduringoperation.
•Nevercleanwithscouringpowders,bleachorharshimplements.
Conventions
WARNINGS–Tohelpavoidpersonalinjury
ImportantNotes/Cautions–fromthefactory
SanitationRequirements
YourCurtisADSSystemisFactoryPre-SetandReadytoGo…RightfromtheCarton.
FollowingaretheFactorySettingsforyourALPHA™GT
CoffeeBrewingSystems:
•BrewTemperature=200°F
•BrewVolume=Settodispensingvesselrequirements(60oz)
•WarmerSettingonHIGHwithQualityTimerOFF
GenerallytherewillneverbeareasontochangeyourG3programming.However,shouldyouneedtomakeslightadjustmentstomeet
yourbrewingneeds,programminginstructionsareprovidedlaterinthismanual.
SystemRequirements:
•WaterSource20–90PSI.Musthaveaminimumowrateof GPM(preferredowrateis1gpm).½
•Electrical:Seeattachedschematicforstandardmodelorvisitwww.wilburcurtis.comforyourmodel.
Equipmenttobeinstalledtocomplywithapplicablefederal,state,orlocalplumbing/electricalcodeshavingjurisdiction.
SETUPSTEPS
Theunitshouldbelevel(lefttorightandfronttoback),locatedonasolidcountertop.Connectawaterlinefromthewaterltertothe
brewer.NOTE:Sometypeofwaterltrationdevicemustbeusedtomaintainatrouble-freeoperation.(Inareaswithextremelyhard
water,wesuggestthatasedimentaryandtaste&odorlterbeinstalled.)Thiswillprolongthelifeofyourbrewingsystemandenhance
coffeequality.
1.A3/8”NPTx1/4”Flareelbowhasbeensuppliedforwaterlineconnection.Usetubingsizedsufcientlytoprovideaminimumof
½ gallon per minute.
2.Connecttheunittoanappropriateelectricalpowercircuit.
3.Turnonthetoggle(STANDBY/ON)switchbehindtheunit.Theheatingtankwillstarttoll.Whenthewaterlevelinthetankrises
tothecorrectvolume,theheatingelementswillenergizeautomatically.WithADSSystemsthereisnodangerofelementburnout
causedbyanemptytank.
4.Theheatingtankwillrequire20to30minutestoreachoperatingtemperature(200°F)asindicatedbyREADY-TO-BREWdisplayed
ontheLED.
5.Priortobrewing,dispense12ouncesofhotwaterthroughthehotwaterfaucet.
6. Brewacycleofatleast12ounces,topurgethewaterlinesofanyairthatmaybetrappedafterlling.
BREWINGINSTRUCTIONS
1.BrewershouldbeON(Conrmatreartoggleswitch,thenpressON/OFFbutton).Ready-to-Brewshouldbedisplayed.
2.Placeemptydecanter(notincludedwithAlphabrewer)onwarmerplate.
3.Placeanewlterinbrewcone.
4.Pourground
coffee into
brewcone.
6. PressBrew
button.
W C C , i .ilbur urtis ompany nC
5. Position
brewcone
intobrew
rails.
WILBURCURTISCOMPANY
Montebello,CA90640
CAUTION:When
cleaning,DONOTuse
powders, liquids, cleans-
ers, or any substance containing
chlorine.Theseproductspromote
corrosion, cause pitting of
stainlesssteelandwillvoidthe
warranty.
NSF International requires the following water connection:
1. Aquickdisconnectoradditionalcoiledtubing(atleast2xthedepthoftheunit)sothatthemachinecanbemovedfor
cleaning underneath.
2. Insomeareasanapprovedbackowpreventiondevicemayberequiredbetweenthebrewerandthewatersupply.
Find out more
on the web
www.wilburcurtis.com
2
Brew Volume
SelectingBrewbyVolumeorBrewbyTimedependsonwhetheryouknowyourbrewtimebeforestarting.FromProgramMenuspress>displaywillnowshow
thenextfeature.
Duringtheactualbrewcycle,a2-minutedripmodeisaddedtothebrewtime.Theprogrammedwaterlevelcompensatesforbacktobackbrewing
Delta3toallowforanincreaseofwatervolume.
Brew by Volume (Factory set to 60 oz.): Press toSelect,DisplaywillnowshowPushSTARTToBegin...PresstheBREWbuttonthenhotwaterstartsrun-
ning,whendesiredvolumeisreachedpressBREWbuttonagaintostoptheow.Nowthevolumehasbeenset.Pressing>buttonwilldisplaythesubsequent
menu features.
Brew by Time (Factory set to 2min40sec).Press toSelecttochangethebrewtime.Displaywillnowshowthecurrenttime.Bypressing<or>youcan
togglebackandforthfromminutestosecondstoexit(ex).Changethetimeorsetandexitbypressing.
Temperature (Factory set to 200°F) Press toSelect.Press<or>tomovetodesiredtemperatureandthen to set. Temperature is programmable from
170ºFto204ºF,in2-degreeincrements.
Energy Save Mode (Factory set to OFF)Press toSelect,<or>ON,OFForON140ºF, toset.WheninON,unitwillautomaticallyshutoff4hours
fromlastbrew.WhenfeatureisOFF,unitdoesnothavetheenergysavingmode.IntheON140ºFposition,temperaturegoesdownto140ºF.ifunithasnot
brewedin4hours.Thisfeaturewillsaveenergybyloweringthetanktemperatureduringperiodsofnon-operation.
Brew Count Odom. Press todisplaytotalgallonsbrewed.PressexorReset
Pre-Infusion (Factory set to OFF)Press toSelect.Currentsettinginsecondsisdisplayed<todecreaseorselect>toincrease(rangefromOFFto10
through60seconds), to set.
IfPre-infusionisselected(ON),ColdBrewLockissettoDelta1within5ºFofsetpointandColdBrewLockisdisappearsfromthelistofprogramselec-
tions.WhenPre-infusionisON,PulseBrewdisappearsfromthelistofprogramselections.
Quality Timer (Factory set to OFF)Press toSelect,<or>OFForON20minutesto120minutesin10minuteincrements.Press to set. An audible
alarmwillsoundwhentimeisexpired.
Brew Count Total Press toSelect,Showstotalgallonsandtotalbrewcyclesontheunit.Isreadonlyandnotresettable
ToGoIntoProgramming
Turnoff(darkdisplay)bypressingON/OFFbutton(yellow).Pressand BREWbutton(green)andthenpressandreleaseON/OFFbutton(yellow).hold
ContinueholdingBREWbutton.Displaywillread ,waituntil isdisplayedEnterthe4-digitaccesscode,thedigits1-4correspondtothebut-
tons(seeillustrationbelow).
Thedefaultcodesetatthefactoryis1-2-3-4.Then willbedisplayed.
YourCurtisG3SystemisFactoryPre-SetforOptimumPerformance.
Afterconnectiontowaterandpower;thereartoggleswitchmustbeon.Youwillhearabeepsound,indicatingpowerisavailabletothecontroller.
Thecontroldisplays .PressON/OFFbuttonandthescreenwilldisplay .Afterthreeseconds, isdisplayed.
Waterwillllthetank(approximately2-3minutesdependingonwaterowrate).Whentheproperlevelisreached willappearonthescreen.Ittakesapproxi-
mately20minutestoreachsetpointtemperatureof200°F.
Controlwilldisplay whentemperaturereachesthesetpoint(200°F).Unitisnowreadytobrew.
<ALP3/4/5>
CURTIS
CURTIS CURTIS
FILLING
CURTIS
HEATING
ENTER CODE
– – – –
PROGRAM MENUS
< SELECT >
CURTIS
READYTOBREW
ENTERING PROGRAM
MODE
1
2 3
4
PROGRAM MENUS
ModelSelect–Alwaysperformthisrst.Thisfeaturere-setsallsettingstothefactorydefaults.
ScrollthroughthemenutoModelSelect.ThechoicesareALPHA-1, ALPHA-2, ALPHA-3/4/5, Airpot Brewer Thermo-Alphaand .YoushouldselectonlyALPHA-1,
ALPHA-2orALPHA-3/4/5.
Allprogrammingselectionsareperformedwiththethreecenterbuttons.
Thesymbolsbelowthebuttonsare:
 ScrollLEFT
SELECTIONorENTERtosavenewparameter
ScrollRIGHT


Produkt Specifikationer

Mærke: Wilbur Curtis
Kategori: Kaffemaskine
Model: Alpha5Gt

Har du brug for hjælp?

Hvis du har brug for hjælp til Wilbur Curtis Alpha5Gt stil et spørgsmål nedenfor, og andre brugere vil svare dig