Læs gratis den danske manual til Austrian Audio OC818 (5 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 22 personer og har en gennemsnitlig bedømmelse på 3.9 stjerner ud af 11.5 anmeldelser. Har du et spørgsmål om Austrian Audio OC818, eller vil du spørge andre brugere om produktet?

Side 1/5
OC818 Large-Diaphragm Condenser Microphone
with Multiple Polar Patterns
Owner Manual ’s
Introduction Safety Instructions and
Please read understand, and follow all instructions in this manual ,
before using this product.
This product was made for professional users and we ask you to
follow a few restrictions to guarantee a hassle-free workflow for you,
and to keep the product in perfect working condition:
Please do not operate this product in other than the
intended use cases.
Do not use if the product is defective
Always keep and operate the product in dry and safe place a
Do not expose it to excessive heat (for example, do not leave
it in your car parked in the sun)
If you need to bring the product inside from the cold, please
give it time to reach adequate temperature before use
(allowed storage temperature range: -25°C 60°C). to
Do not operate outside the intended operating temperature range: 0°C 55°C to
Do not use this product in wet or in humid environment a
Do not drop
When used upside down (for example in the OCH8 or OCS8) make sure that a tight fit is
achieved and do not operate it upside down right above personnel
Only connect the back output of the OC818 to an OCR8 Bluetooth® dongle or the OCC8 mini
XLR cable. Do not connect that output to any other devices
This product requires a phantom power source of 48V (+/-4V), max draw is 4mA (with OCR8
connected).
Please keep this product away from small children and persons who are not able to operate
professional audio equipment (some sound technicians with gray pony-tails included)
If you need to clean the product, do this only with a soft dry cloth
Please do not use any third-party accessories unless otherwise stated
Do not disassemble the product, as there are no user-serviceable parts inside (but plenty of
components to mess up)
The length of the XLR cable must not exceed 30m.
Do not remove the sticker
Thank you for reading the instructions so far, and thank you for putting your trust in Austrian Audio.
How to Operate the OC : 818
The OC818 requires phantom power, so please make sure that you are supplying it according to P48
(48V +/- 4V). Peak current consumption is below 4 mA (OC818 with OCR8 connected). Almost all
state- -the-art professional mixing consoles, preamps and audio interfaces provide enough power, of
however some battery driven, or older devices may fail to do so!
Setting up the OC818:
For optimum performance, do not cover the grill of the OC818, and always ensure a secure fit in the
OCH8 (holder) or OCS8 (suspension).
Always place your sound source to face our beautiful logo!
If you record in figure-8, then you can also use the rear side. Or if you record in Omnidirectional, then
it does not matter at all. Or if you pick up a Leslie cabinet and are experimenting with the phase-
shifting-effects. But otherwise: Please face the logo!
Adjusting the Polar Pattern:
The OC818 provides 4 default directional characteristics: figure-8, supercardioid, cardioid and
omnidirectional. The 5th setting ( ) is called ”. If you own an OCR8 Bluetooth dongle Preset Mode
you can program your custom pattern to this position. Factory setting (before you change the
pattern by an OCR8) for this position is broad-cardioid without High Pass Filter and Pad Switch
those are inactive in Preset Mode.
Switch the polar pattern selector to the desired pattern. Please note that the microphone needs a
few seconds to adapt to the new pattern, especially if you switch all the way from figure-8 (left) to
omni (right) or vice versa (this gives any sluggish electrons time to catch up).
High Pass Filter:
The high pass filter is a powerful tool to reduce unwanted low frequencies, like stage noise, handling,
or your Uncle Albert’s singing.
'' ''0 means not active
'' ''40 is a high pass 2nd order filter at 40 Hz
'' ''80 is a high pass 2nd order filter at 80 Hz
'' ''160 is a high pass 1st order filter from 160 Hz to 80 Hz, and a high pass 2
nd order filter below 80 Hz.
Pad Switch:
The Pad switch reduces the sensitivity of the microphone and prevents overloading the microphone
in loud environments.
'' ''0 means not active
'' ''-10 means that the microphone is 10 dB less sensitive
'' ''-20 means that the microphone is 20 dB less sensitive
'' ''-30 means you may need to see an optician, as there is no 30” position.-
Note: The -10dB position reduces the bias voltage of the capsule, so the microphone can take 10dB
more input (I am looking at you there, trombone jockey), whereas the -20db Setting reduces the gain
by another 10 dB to protect your mixer preamp from overload.


Produkt Specifikationer

Mærke: Austrian Audio
Kategori: Ikke kategoriseret
Model: OC818

Har du brug for hjælp?

Hvis du har brug for hjælp til Austrian Audio OC818 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Austrian Audio Manualer

Austrian Audio

Austrian Audio OC818 Manual

4 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Rane

Rane THX 22 Manual

19 Juni 2025
Icom

Icom LC-192 Manual

19 Juni 2025
Curtis

Curtis 840 Manual

19 Juni 2025
Physa

Physa PHY-TW-02 Manual

19 Juni 2025
Ridgid

Ridgid RST100 Manual

19 Juni 2025
Chapin

Chapin 97761E Manual

19 Juni 2025
Fiamma

Fiamma Compass Manual

19 Juni 2025
Fiamma

Fiamma A20 Manual

19 Juni 2025