Læs gratis den danske manual til Berner Commercial Low Profile 8 (12 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 2 anmeldelser. Har du et spørgsmål om Berner Commercial Low Profile 8, eller vil du spørge andre brugere om produktet?

Side 1/12
-1-
TABLE OF CONTENTS
I. UNCRATING........................................................................................................................................................................ 2 ..
II. MOUNTING INSTRUCTIONS........................................................................................................................................... 4 ..
III. WALL MOUNTING........................................................................................................................................................... .. 5
IV. SUSPENDED MOUNTING.............................................................................................................................................. 5 ...
V. ELECTRICAL CONNECTIONS 6 ...........................................................................................................................................
VI. FIELD CONNECTIONS .................................................................................................................... 6 ..................................
VII. OPERATING INSTRUCTIONS ................................................................................................................................. 7 ........
VIII. MAINTENANCE AND CLEANING .................................................................................................................. 8 ...............
IX. SERVICE ............................................................................................................................................................. 9 ................
X. TROUBLESHOOTING ....................................................................................................................................................... 10
XI. WARRANTY ...................................................................................................................................................... ............... 12
ANSI/NSF 37
Air Curtain Fans
max.mounting
height is 7’
SLC07
for outdoor use
SLC07
indoor use
CLC08
II-480
July, 2024
©Copyright, 2024 Berner International
READ ALL INSTRUCTIONS BEFORE INSTALLING OR USING AIR CURTAIN
Commercial Low Prole 8
Sanitation Certied Low Prole 7
Air Curtain Series
#CLC08 & #SLC07
www.Berner.com
®
WHEN THE DOORS ARE OPEN
save energy & create healthy, comfortable environments
Installation & Maintenance Instructions
USDA
COMPLIANCE
FDA
RECOMMENDED
Thank you for choosing Berner.
Berner International has been saving energy and creating healthy, comfortable environments for our customers
for over 60 years. Berner oers unmatched quality, performance, and dependability—not to mention our service.
At Berner, we stand behind our products.
-2-
Carefully examine the carton(s) for damage. If the carton is damaged,
immediately notify the shipping company. Do not delay inling claim.
If the air curtain(s) were shipped on wooden skids, remove protective
wood and banding straps securing the carton(s) to the skid. Open the
carton(s) and remove all protective packaging.
Immediately verify that the electrical rating nameplate located on the
cover matches electrical power supply available. Retain the shipping
carton(s) until the air curtain(s) are installed and properly operating.
ACCESSORIES: The air curtain ships with a wall mounting plate;
remove and save the two (2) locking screws from the back corners and
detach the wall mounting plate.
See FIGURE 1.
If the air curtain(s) were ordered with optional electrical accessories, the
accessories will be found in the carton containing the air curtain packed
in a red bag (marked additional parts inside”) or in a separate carton(s)
accompanying the air curtain(s).
Check all of the cartons/skids for accessories before discarding.
I. UNCRATING
Commercial
role 8
urtain
C08
A. Read all instructions before installing or using this air curtain.
B. Use this unit only in the manner intended by the manufacturer and described in this manual. Any other use not recommended by the
manufacturer may cause re, electric shock, or injury to persons. If you have any questions, contact the manufacturer.
C. Before servicing or cleaning unit, switch power o at service panel and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
D. Installation work and electrical wiring must be done by qualied person(s) in accordance with all applicable national and local codes
having jurisdiction, including re-rated construction. See page 6, ELECTRICAL CONNECTIONS (NEC Code ANSI/NFPA No. 70).
E. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
F. To reduce the risk of re, do not store or use gasoline or other ammable vapors and liquids in the vicinity of the air curtain.
G. This air curtain is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture,
pillows, bedding, papers, clothes, etc. and curtains at least 1 inch from the top, back, front, sides and at least 6 feet from the discharge
of the air curtain.
H. Extreme caution is necessary when any air curtain is used by or near children or invalids, and whenever the heater is left operating
I. Do not operate any air curtain after it malfunctions. Disconnect power at the service panel and have the air curtain inspected by a
reputable electrician before reusing.
J. To disconnect the air curtain, turn controls to "o", and turn o power to the air curtain circuit at main disconnect panel.
K. Do not insert or allow foreign objects to enter any ventilation or discharge opening as this may cause an electric shock or re, or
damage the air curtain.
L. To prevent a possible re, do not block the air intake or discharge of the air curtain in any manner.
M. The air curtain has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or ammable vapors or liquids
are used or stored.
N. This heater may include an audible or visual alarm to warn that parts of the heater are getting excessively hot. If the alarm sounds
(or illuminates), immediately turn the heater o and inspect for any objects on or adjacent to the heater that may have blocked the airow
or otherwise caused high temperatures to have occurred. DO NOT OPERATE THE HEATER WITH THE ALARM SOUNDING (OR ILLUMINATING).
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: