Canarm ALX165-DD100EC Manual

Canarm Emhætte ALX165-DD100EC

Læs gratis den danske manual til Canarm ALX165-DD100EC (14 sider) i kategorien Emhætte. Denne vejledning er vurderet som hjælpsom af 32 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 16.5 anmeldelser. Har du et spørgsmål om Canarm ALX165-DD100EC, eller vil du spørge andre brugere om produktet?

Side 1/14
ALX SERIES
SPUN ALUMINUM EXHAUSTER
OPERATION INSTRUCTIONS AND PARTS MANUAL
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY
1. All electrical work must be done in accordance with all applicable electrical codes by a
qualified electrician.
2. Prior to wiring ensure the power supply is locked in the OFF position and that the motor
nameplate voltage matches the supply voltage.
3. Do not install or operate this fan in an environment where combustible materials, gases or
fumes are present.
4. Caution: the fan contains rotating parts and electrical service. Appropriate safety
precautions should be taken during installation, operation and maintenance.
When servicing the fan motor may be hot, allow time for cooling down.
5. Before starting the unit, ensure the wheel rotates freely.
6. Check and tighten where necessary all nuts, bolts & set screws prior to fan start up (as
some may have loosened during shipment).
7. Please follow all applicable national, state/provincial and local codes, all of them will
supersede this manual.
8. Failure to follow the safety instructions in this manual may cause serious injury or
death due to electrical shock or high speed rotating parts.
The purpose of this manual is to aid in the proper installation and operation of the blowers. These instructions are intended to supplement good
general practices and are not intended to cover detailed instruction procedures.
IT IS THE RESPONSIBILITY OF THE PURCHASER TO ASSURE THAT THE INSTALLATION AND MAINTENANCE OF THIS EQUIPMENT IS
HANDLED BY QUALIFIED PERSONNEL.
Inspect all shipments carefully for damage. THE RECEIVER MUST NOTE ANY DAMAGE ON THE CARRIER’S BILL OF LADING AND FILE A
CLAIM IMMEDIATELY WITH THE FREIGHT COMPANY.
DO NOT LIFT THE UNIT BY THE HOOD OR MOTOR. PLEASE LIFT THE UNIT BY HORIZONTAL SUPPORTS.
THESE ARE GENERAL INSTRUCTIONS WHICH COVER OUR DIRECT DRIVE AND BELT DRIVE EXHAUSTERS. A VARIETY OF MOTORS ARE
USED INCLUDING SINGLE AND THREE PHASE, SINGLE SPEED ONLY AND VARIABLE SPEED CAPABLE, ELECTRONICALLY CONTROLLED
(ECM) AND INDUCTION MOTORS. PLEASE REVIEW THE FAN AND MOTOR ELECTRICAL DATA CAREFULLY AND REFER TO THE SECTION
OF THE MANUAL THAT APPLIES TO YOUR PRODUCT.
DIMENSION & COMPONENT
ALX-M-16_10_24 Page 1 of 7
A
B
D
E
C
G
F
A
B
D
E
C
G
F
UPBLAST
MODELS
DOWNBLAST
MODELS
NOTE: DUE TO MOTOR MANUFACTURERS VARIANCES IN DESIGN,
PLEASE SEE PAGE 5 FOR MOTOR DIMENSIONAL GUIDELINES.
DOWNBLAST UPBLAST
Downblast Direct
Drive Shown
Upblast Belt
Drive Shown
Motor plate detail varies
on different sizes
Model A B C D E F G Ø
Wheel
Diameter
Roof
Opening
Net
Weight
(lbs)
ALX105-DD 18.00 25.00 19.00 2.50 1.50 3.50 0.38 10.50 15.00 33
ALX120-DD 19.00 25.00 19.00 3.50 1.50 3.50 0.38 12.25 15.00 35
ALX135-DD/DB 22.25 / 25.25 31.25 21.00 3.13 2.00 3.75 0.44 13.50 17.00 51 / 59
ALX150-DD/DB 23.13 / 26.13 31.25 21.00 3.75 2.00 3.75 0.44 15.00 17.00 56 / 65
ALX165-DD/DB 27.13 / 31.13 36.25 24.75 5.00 2.00 4.00 0.44 16.50 20.75 100 / 106
ALX180-DD/DB 27.75 / 31.75 36.25 28.00 5.50 2.00 4.00 0.44 18.25 20.75 104 / 110
ALX210-DB 36.25 43.75 33.13 5.25 2.50 4.00 0.44 21.25 29.00 176
ALX245-DB 37.00 43.75 33.13 5.88 2.50 4.00 0.44 24.50 29.00 181
Dimension s (inches)
Model A B C D E F G Ø
Wheel
Diameter
Roof
Opening
Net
Weight
(lbs)
ALX105-UD 17.63 25.00 19.00 13.00 1.50 3.50 0.38 10.50 15.00 35
ALX120-UD 18.63 25.00 19.00 13.00 1.50 3.50 0.38 12.25 15.00 37
ALX135-UD/UB 22.25 / 25.25 32.13 21.00 17.13 1.50 3.75 0.44 13.50 17.00 53 / 62
ALX150-UD/UB 23.13 / 26.13 32.13 21.00 17.13 1.50 3.75 0.44 15.00 17.00 58 / 67
ALX165-UD/UB 27.13 / 31.13 37.50 24.75 21.13 2.00 4.00 0.44 16.50 20.75 100 /108
ALX180-UD/UB 27.75 / 31.75 37.50 28.00 21.13 2.00 4.00 0.44 18.25 20.75 108 / 116
ALX210-UB 36.25 43.75 33.13 25.50 2.50 4.00 0.44 21.25 29.00 178
ALX245-UB 37.00 43.75 33.13 25.50 2.50 4.00 0.44 24.50 29.00 183
Dimension s (inches)
!
Note: Belt drive units are
weighted without motor
& drives.


Produkt Specifikationer

Mærke: Canarm
Kategori: Emhætte
Model: ALX165-DD100EC

Har du brug for hjælp?

Hvis du har brug for hjælp til Canarm ALX165-DD100EC stil et spørgsmål nedenfor, og andre brugere vil svare dig




Emhætte Canarm Manualer

Canarm

Canarm SIS1510300 Manual

17 September 2025
Canarm

Canarm SIS910150 Manual

17 September 2025
Canarm

Canarm SIG910150 Manual

17 September 2025
Canarm

Canarm SIS1530300M Manual

17 September 2025
Canarm

Canarm SIS1010150 Manual

26 August 2025
Canarm

Canarm BI-10RM Manual

25 August 2025
Canarm

Canarm BI-12RM Manual

25 August 2025

Emhætte Manualer

Nyeste Emhætte Manualer

Faber

Faber INSP28SS240 Manual

4 November 2025
Artusi

Artusi ATH901B Manual

4 November 2025
Faber

Faber HILTIS36SSNB Manual

4 November 2025
Witt

Witt WFT916G Manual

4 November 2025
Faber

Faber SCIR3614SSNB-B Manual

4 November 2025
Faber

Faber CRIS36SS300 Manual

4 November 2025
Witt

Witt Stream 60 WN Manual

3 November 2025
Artusi

Artusi ATH901MB Manual

3 November 2025
Faber

Faber CRIS36SS600 Manual

3 November 2025