Champion Tuff Grills CG 64 Manual


Læs gratis den danske manual til Champion Tuff Grills CG 64 (5 sider) i kategorien Grillplade. Denne vejledning er vurderet som hjælpsom af 24 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 12.5 anmeldelser. Har du et spørgsmål om Champion Tuff Grills CG 64, eller vil du spørge andre brugere om produktet?

Side 1/5
The Champion/Tuff Grill (Wood Fired Grill) Chef Series is to be installed according the
following design criteria:
CODES & STANDARDS
The Champion/Tuff Grill Chef Series grills are designed to use Solid Fuels for
commercial cooking applications. These grills are NSF approved for use in commercial
kitchens by NSF International. The use of Solid Fuels (hardwood, mesquite, charcoal
briquettes or charcoal chunks) in commercial kitchen applications is regulated by NFPA
96. NFPA 96 is a standard issued by the National Fire Protection Association for the
“Ventilation Control & Fire Protection of Commercial Cooking Operations”. All
electrical components used are Underwriters Laboratory (UL) certified. All gas
components are American Gas Association (AGA) certified. Local codes governing Fire
Safety in Commercial Kitchens / Food Preparation Areas and Pollution Control may offer
alternate restrictions. Local Codes or Standards always overrule National Standards
should conflicts arise between the standards.
EXHAUST
The Champion/Tuff Grill Chef Series grills are designed for indoor use under an
approved canopy style exhaust hood with an approved fire suppression system for solid
fuel appliances. The exhaust hood must extend a minimum of 12 inches on each side and
18 to 24 inches in the front larger than the cooking area dimensions of the grill. Other
local codes or restrictions may apply.
The following are ventilation exhaust hood requirements paraphrased from NFPA 96:
The powered exhaust hood must capture all effluent (smoke & vapors) emitted from the grill.
The exhaust cannot terminate through a wall and cannot be of a recirculating type.
Makeup air must be available in accordance with the exhaust hood manufacturer specifications.
The spark arrestor screen or filter must be periodically inspected and cleaned to prevent exhaust
ventilation restriction.
FLOOR REQUIREMENTS
These grills are designed to be setup and operated on a non-combustible floor surface
extending 3 feet in all directions from the grills cooking surface. The floor is to be level
and structurally sufficient to support the weight of the grill. The cooking surface shall be
located 30 inches minimum above the floor. See the grill specifications for full
dimensional and weight data.
GRILL LOCATION COSIDERATIONS
The Champion/Tuff Grill Chef Series units are designed for installation with 3 feet of
clearance on the back and sides from objects such as a deep fat fryer or other hot oil or
grease appliance. There must exist at least 16 inches of space in between the hot oil or
grease appliance (deep fryers) and any flames possibly emitting from the grill. If a steel
or glass baffle is erected between the grill and the hot oil or grease appliance, the baffle
must extend at least 8 inches higher than the oil or grease appliance and any potential
flames emitting from the grills cooking surface or firebox door areas.
The Tuff Grill is equipped with a Gas Fired Log Starter and shall be located with the gas
regulator at least 3 feet from any heat-emitting device where the temperature to the gas
regulator unit would be greater than 150 degrees Fahrenheit and located in a naturally
ventilated area.
The sides of the Champion/Tuff Grill are designed not to exceed 300 degrees Fahrenheit
during maximum fired grilling operations. No combustible materials should be within 3
inches of contact with the external sides or back surface of the grill body during fired
operations. Combustible materials shall never be stored above or below the grill.
PROPER CLOTHING
Please take note that an open flame can produce temperatures around 2,000 degrees
Fahrenheit and can cause serious burns or ignite clothing. A fire-retarding apron and
sleeves should be considered when cooking on a Champion/Tuff Grill Chef Series as
grease flare-ups can happen at any time. Proper clothing should always be worn so as to
not allow exposure to the open flame or hot surfaces of the grill. Particular care should be
taken when adding fuel or adjusting the fuel loading in the firebox. It is recommended
that fire proof insulated oven gloves or mitts and long handled tongs or other tools be
used when adjusting the fuel load. Also keep in mind that the cast iron grates and ash
drawers may remain hot long after the fires flame has gone out.
SAFE OPERATION


Produkt Specifikationer

Mærke: Champion Tuff Grills
Kategori: Grillplade
Model: CG 64

Har du brug for hjælp?

Hvis du har brug for hjælp til Champion Tuff Grills CG 64 stil et spørgsmål nedenfor, og andre brugere vil svare dig