Læs gratis den danske manual til Chauvin Arnoux C.A 6117 (112 sider) i kategorien Måling. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 2 anmeldelser. Har du et spørgsmål om Chauvin Arnoux C.A 6117, eller vil du spørge andre brugere om produktet?

Side 1/112
Installation testers
EN - User’s manual
C.A 6116N
C.A 6117
2
WARNING, risk of DANGER! The operator must refer to these instructions whenever this danger symbol appears.
Useful information or tip. Current clamp.
USB socket. Auxiliary rod.
The voltage on the terminals must not exceed 550 V. Equipment protected by double insulation.
The product is declared recyclable following a life cycle analysis in accordance with standard ISO 14040.
Chauvin Arnoux has adopted an Eco-Design approach in order to design this appliance. Analysis of the complete
lifecycle has enabled us to control and optimize the e󰀨ects of the product on the environment. In particular this appli-
ance exceeds regulation requirements with respect to recycling and reuse.
The CE marking indicates compliance with the European Low Voltage Directive (2014/35/EU), Electromagnetic
Compatibility Directive (2014/30/EU), and Restriction of Hazardous Substances Directive (RoHS, 2011/65/EU and
2015/863/EU).
The UKCA marking certies that the product is compliant with the requirements that apply in the United Kingdom, in
particular as regards Low-Voltage Safety, Electromagnetic Compatibility, and the Restriction of Hazardous Substances.
The rubbish bin with a line through it indicates that, in the European Union, the product must undergo selective disposal
in compliance with Directive WEEE 2012/19/EU. This equipment must not be treated as household waste.
PRECAUTIONS FOR USE
This instrument is compliant with safety standard IEC/EN 61010-2-034 and the leads are compliant with IEC/EN 61010-031, for
voltages of 600V category III or 300V in category IV (under shelter).
Failure to observe the safety instructions may result in electric shock, re, explosion, and destruction of the instrument and of the
installations.
Do not exceed the maximum rated voltage and current and the measurement category.
Never exceed the protection limits indicated in the specications.
Comply with the conditions of use, namely the temperature, the humidity, the altitude, the degree of pollution, and the place of use.
Do not use the device or its accessories if they seem damaged.
Do not use the device if the battery compartment cover is missing or incorrectly installed.
To recharge the battery, use only the mains adapter unit provided with the device.
To replace the battery, disconnect everything connected to the device and set the switch to OFF.
Do not use a battery with a damaged jacket.
Use connection accessories of which the overvoltage category and service voltage are greater than or equal to those of the
measuring device (600 V Cat. III or 300 V Cat. IV).
Troubleshooting and metrological checks must be done only by accredited skilled personnel.
Wear the appropriate protective gear.
Thank you for purchasing a C.A 6116N or C.A 6117 installation tester.
To obtain the best service from your unit:
read this user manual carefully,
comply with the precautions for use.