ClimeMET CM2011 Manual


Læs gratis den danske manual til ClimeMET CM2011 (2 sider) i kategorien Termometer. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 2 anmeldelser. Har du et spørgsmål om ClimeMET CM2011, eller vil du spørge andre brugere om produktet?

Side 1/2
CM2011
WIRELESS THERMOMETER
Instruction Manual
Please note: For optimum performance we would suggest placing the remote sensor in a
sheltered environment. Direct rainfall can affect the accuracy of your outdoor readings and
cause lasting damage to the device.
Contents:
1. 1 x Indoor station
2. 1 x Remote sensor
3. Instruction Manual
Functions:
l Indoor temperature
l Outdoor temperature
l Minimum/Maximum temperature
l Indoor Humidity
Quick Setup:
Please note: Use good quality Alkaline batteries and avoid using any form of
rechargeable batteries.
1. Place the batteries into the indoor receiver first, followed by the batteries
for the remote sensor.
2. Within one minute the outdoor temperature data will be displayed
indicating that the receiver has synchronized with the transmitter. You
can then place the remote sensor outdoors and set the correct time.
3. If there is no outdoor temperature reading displayed on the indoor
station, make sure the units are within range of each other and repeat
the battery installation procedure. If a key is pressed before the weather
station receives the temperature signal, it will take 10 minutes before the
receiver re-synchronizes with the outdoor sensor. If a reset is
required for the receiver or transmitter, remove the batteries and
wait 10 seconds before re-inserting the batteries to ensure a
correct reset.
Key Operation:
There are two different function modes available: ˚C/˚F mode and Min/Max
mode.
Setting Mode:
Press the ˚C/˚F key once and the temperature will switch from ˚C to ˚F. Press
the same key again to change it back.
Min/Max Mode:
Press the min/max key once and the minimum indoor and outdoor
temperatures will be displayed.
Press the min/max key again and the maximum indoor and outdoor
temperatures will be displayed.
Press the min/max key a third time and the current temperature will be
displayed.
Press and hold the Min/Max key for 2 seconds and the recorded minimum or
maximum temperature will be reset to the current indoor/outdoor temperature.
If no key is pressed for 30 seconds the unit will switch itself back to normal
display mode automatically.
Specification:
l Indoor temperature range: -20°C to +60°C
l Indoor humidity range 20%-98%
l Outdoor temperature range: -40°C to +65°C
l Temperature accuracy: +/-1.0°C
l Humidity accuracy: +/-5%
l Power requirement (indoor station): 2xAAA LR3 alkaline batteries
l Power requirement (remote sensor): 2XAAA LR3 alkaline batteries
l Battery life: 12 months for receiver (approx)
l 24 months for transmitter (approx)
l Transmission frequency: 433.9MHz
l Transmission range: up to 50 meters (150 feet) in an open area
Caution:
l Do not reverse the polarity of the batteries
l Do not put the receiver close to metal
l Avoid exposing the remote sensor directly to rain
How to fix the outdoor sensor:
Note: To achieve a true temperature reading you should avoid mounting the
sensor in direct sunlight. We recommend that you mount the remote sensor
on an outside North-facing wall; obstacles such as walls, concrete, and large
metal objects will reduce the transmission range.
To wall mount the sensor, insert one correctly sized screw to the desired wall
and hang the outdoor sensor on the screw.
The outdoor sensors electronic components are coated with anti-humidity
resin, to protect the circuit function properly. However, the sensor is not
waterproof and exposing the sensor directly to rain should be avoided.
FCC STATEMENT
1. This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired
operation.
2. Changes or modifications not expressly approved by the
party responsible for compliance could void the users
authority to operate the equipment.


Produkt Specifikationer

Mærke: ClimeMET
Kategori: Termometer
Model: CM2011

Har du brug for hjælp?

Hvis du har brug for hjælp til ClimeMET CM2011 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termometer ClimeMET Manualer

ClimeMET

ClimeMET CM2011 Manual

29 September 2025
ClimeMET

ClimeMET CM4302 Manual

31 August 2024
ClimeMET

ClimeMET CM3011 Manual

31 August 2024
ClimeMET

ClimeMET CM3012 Manual

31 August 2024
ClimeMET

ClimeMET CM3086 Manual

31 August 2024

Termometer Manualer

Nyeste Termometer Manualer

Scala

Scala SC 312 Manual

30 September 2025
Inkbird

Inkbird INT-11X-B Manual

28 September 2025
Inkbird

Inkbird IDT-34c-B Manual

28 September 2025
Inkbird

Inkbird INT-12E Manual

28 September 2025
Neno

Neno Medic T07 Manual

25 September 2025
Brandson

Brandson 306118 Manual

15 September 2025
TFA

TFA 30.3072.01.90 Manual

12 September 2025
Berdsen

Berdsen BD-101 Manual

9 September 2025