Cointra Thermex Blitz IBL Manual

Cointra Kedler & kedler Thermex Blitz IBL

Læs gratis den danske manual til Cointra Thermex Blitz IBL (9 sider) i kategorien Kedler & kedler. Denne vejledning er vurderet som hjælpsom af 27 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 14 anmeldelser. Har du et spørgsmål om Cointra Thermex Blitz IBL, eller vil du spørge andre brugere om produktet?

Side 1/9
1
Before the first using your electric storage water heater, carefully read this operation
manual and pay special attention to paragraphs marked with «Attention» symbol.
Dear customer! Congratulations on your purchase of THERMEX electric water heater. We are
convinced that a wide range of our electric water heaters will satisfy any of your needs. Use of modern
technologies and the highest quality materials when manufacturing devices have contributed to gaining
popularity and trust to THERMEX trade mark.
THERMEX electric water heaters are designed and manufactured in strict accordance with domestic
and international standards guaranteeing reliability and safety of operation.
Present operation manual applies to THERMEX models series IBL, volume 10, 15 liters. In all
models Silver Heat heating element can optionally be installed. The full name of your heater model of
is specified in section “Manufacturer’s Guarantee” (sub-section "Note of sale") and in the
identification plate on the casing of the heater.
1. Application
Water heater (hereinafter EWH) is designed to provide with hot water for welfare and industrial
facilities that have cold water supply main with appropriate characteristics.
EWH shall be operated in closed heated spaces and is not designed for continuous flowing mode.
2. Main technical characteristics
Maximum cold water main pressure – 0.7 MPa
Minimum cold water main pressure – 0.05 MPa
Parameters of the power supply - single-phase network with voltage (220 V ± 10%) and +1% 50
Hz + 1%
Power of tube heater is adjustable in steps:
1.5 kW - save heating mode
2.5 kW - full heating mode (TURBO mode)
Thread diameter of hot and cold water connecting pipes - ½
Heater protection class - IPX4
EN
Model
Volume
(l)
Average heating
time
=450 , Т С
(.5 kW)
Permanent
subsistence
loss (kWh/24
h)
Actual annual energy
consumption * (*Permanent
subsistence loss) (kW/h)
IBL 10O, 10U 10 16 min. 0,56 204,4
IBL 15O, 15U 15 28 min. 0,69 251,8
3. Scope of supply
1. Water heater ..................................................
1 pc.
2. Pressure relief valve GP type ............................ 1 pc.
3. Operation manual ........................................ 1 pc.
4. Packaging ...........................................................................1 pc.
5. Anchors for fastening.......................................................... 2 PCs. for each clamping bar
2
EN
4. Description and principle of operation
EWH consists of the housing, removable flange, safety valve, protective cover and Control Panel.
4.1.
The housing consists of the outer shell, made of plastic, internal tank, thermal insulated with
environmentally friendly polyurethane foam, and two threaded pipes for cold water inlet (blue ring) and
hot water exhaust (red ring).
Internal tank is made of stainless austenitic stainless steel, which ensures high corrosion resistance
and, as a consequence, long operation life.
4.2.
At the removable flange the following is mounted: tubular heater (HEATER), pipe thermostat.
TEH is used to heat water and thermostat provides with possibility to adjust temperature up to +74°
C C). Temperature adjustment is made using adjustment knob located on the water heater
control panel (Fig. 1).
The thermal switch is used to prevent overheating and cut off EWH power when water
temperature exceeds +95° C (± 5° c) (fig. 2). EWH housing can heat inthe course of operation.
Two warning lights (button) located on the control panel (fig. 1) of the water heater next to the
temperature adjustment knob indicate operating mode: "POWER" light is on when the save mode
(1.5 kW), and TURBO light - when the full heating mode (2.5 kW). Switching between the modes is
made by pressing TURBO button, when button pressed "TURBO" mode is on, when released – save
mode. EWH power on/off is carried out by POWER button.
4.3.
Safety valve is back-flow valve preventing ingress of water from the water heater to
water main in case of pressure drop in the latter and in case of pressure increase in the tank
when water is heating up, as well as safety valve, relieving excess pressure in tank when water
is heating up. During water heater operation water may leak out of the exhaust outlet pipe of the
safety valve to relieve excessive pressure, which is made for the purpose of water heater
safety. This outlet pipe shall remain open to the atmosphere and be installed constantly down.
and in a non-freezing environment. You shall ensure drainage of water from exhaust pipe safety
valve into the drain, with installation of the corresponding EWH drainage.
It is required regularly (at least once a month) to discharge a small amount of water through the
exhaust pipe of the safety valve into the drain to remove lime deposits and to test the operating
functionality of the valve. Handle is intended to open the valve. It is necessary to control when
operating water heater this handle to be in position closing water draining from the tank.
5. Specifying security measures
5.1.
Electrical safety and corrosion protection of EWH are guaranteed only if there is an effective
earthing in accordance with applicable electric installation rules and regulations.
5.2.
Plumbing pipes and fittings shall conform to parameters of water main and have the required
certificates of quality.
5.3.
When installing and operating EWH the following is not allowed.


Produkt Specifikationer

Mærke: Cointra
Kategori: Kedler & kedler
Model: Thermex Blitz IBL

Har du brug for hjælp?

Hvis du har brug for hjælp til Cointra Thermex Blitz IBL stil et spørgsmål nedenfor, og andre brugere vil svare dig




Kedler & kedler Cointra Manualer

Cointra

Cointra Optima 11 D Manual

1 September 2024
Cointra

Cointra Thermex IF Manual

1 September 2024
Cointra

Cointra TNC 10 Manual

1 September 2024
Cointra

Cointra TL Plus 30 S Manual

1 September 2024
Cointra

Cointra Optima COB-5p Manual

1 September 2024
Cointra

Cointra Thermex ID Manual

1 September 2024
Cointra

Cointra TNC- 100 H Manual

1 September 2024
Cointra

Cointra TNC-15 Manual

1 September 2024
Cointra

Cointra Optima COB-5N Manual

1 September 2024

Kedler & kedler Manualer