  CLTIBN Terminal Blocks 
Functional Summary 
The Crestron
®
 CLTIBN series of terminal blocks with 
circuit breakers provide an additional wiring option when 
installing Crestron CLXI-series modules in a Crestron 
CAENIB automation enclosure. CLTIBN terminal blocks 
feature 10A type “C” load-side breakers that offer 
additional circuit protection where desired, or where 
required by local electrical codes. CLTIBN terminal 
blocks ship separately from their corresponding CLXI 
modules to permit termination of the field wiring to the 
CLTIBN prior to installation of the module. Every 
CLTIBN includes a door kit and an adhesive circuit label 
(for labeling circuits) to be installed on the cover of the 
CAENIB enclosure. This door kit allows access to the 
circuit breakers located on the CLTIBN without removing 
the cover of the CAENIB enclosure.  
Crestron Electronics, Inc.  Installation Guide – DOC. 6561A 
15 Volvo Drive   Rockleigh, NJ 07647  (2017315)  
Tel: 888.CRESTRON  04.07   
Fax: 201.767.7576   Specifications subject to  
www.crestron.com  change without notice. 
Industry Compliance 
This product complies with the essential requirements of 
all applicable EU directives.  
 
Installation 
The terminal block and module must be mounted into a 
CAENIB Enclosure by a licensed electrician, in 
accordance with all national and local codes.  
CAUTION:  This equipment is for indoor use only and 
needs to be air-cooled. Mount in a well-ventilated area. 
The ambient temperature must be 0°C to 40°C (32°F to 
104°F). The relative humidity must be 0% to 90% (non-
condensing).  
Terminal blocks are installed along the left side of single-
wide enclosures and along the outside edges (left and 
right sides) of double-wide enclosures. Modules are 
installed along the right side of single-wide enclosures 
and side-by-side in the center of double-wide enclosures. 
When installing modules and terminal blocks in a double-
wide enclosure, be sure to invert units on the right side so 
that they can be properly wired. Refer to the illustrations 
shown in the next column and next page when 
considering the location of terminal blocks and modules 
within an enclosure.  
NOTE:  For applications where an RCCBO (Residual 
Current Circuit Breaker with Overload) is needed, the 
CLTIBN’s breaker must be replaced with an RCCBO 
(supplied by other). Note that the presence of an RCCBO 
requires the CLXI module to be mounted in a different 
location to allow for the added size of the new breaker. 
Refer to the latest version of the CAENIB Installation 
Guide (Doc. 6562) which is available for download from 
the Crestron website (
www.crestron.com/manuals). 
NOTE:  To insure proper fit, terminal blocks and 
modules must be installed at the locations indicated in the 
latest version of the CAENIB Installation Guide. 
NOTE:  Modules and terminal blocks must be installed 
into the lowest available spaces and continue toward the 
top of the enclosure. 
Terminal Block & Module Locations (Single-wide Enclosure) 
WIRING MODULE