Læs gratis den danske manual til Crestron CLX-DIN-AP3 (2 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 17 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 9 anmeldelser. Har du et spørgsmål om Crestron CLX-DIN-AP3, eller vil du spørge andre brugere om produktet?

Side 1/2
CLX-DIN-AP3 & CLX-DIN-AP3-HUB
Crestron Electronics, Inc. Installation Guide DOC. 7608B
15 Volvo Drive Rockleigh, NJ 07647 (2038184)
Tel: 888.CRESTRON 01.14
Fax: 201.767.7576 Specifications subject to
www.crestron.com change without notice.
Introduction
The Crestron
®
CLX-DIN-AP3 3-Series Control System
®
is designed for CAEN, CAEN-MLO, and CAENIB
Automation Enclosures. There are two models. The
CLX-DIN-AP3 model includes a DIN-AP3 3-Series
®
Automation Processor and DIN-PWS30-277 Cresnet
®
Power Supply prewired and mounted on a
CAEN-UMP1X2 Universal Mounting Plate. Model
CLX-DIN-AP3-HUB includes the DIN-HUB Cresnet
Distribution Hub as well.
Refer to the illustration on this page for an example of
mounting location and orientation within a single-wide
enclosure. The table beneath the illustration lists the
dimensions and weight.
The CLX-DIN-AP3 and CLX-DIN-AP3-HUB install in
an identical manner. For simplicity within this guide, the
term “CLX-DIN-AP3” is used except where noted.
Installation
The CLX-DIN-AP3 must be mounted in accordance with
all national and local codes.
NOTE: Adhere to Class 1 and Class 2 wiring
requirements when considering the equipment attached to
the CLX-DIN-AP3 in an enclosure.
Use the four screws (8B x 1/4”, supplied) to attach the
CLX-DIN-AP3 to a CAEN, CAEN-MLO, or CAENIB
Automation Enclosure. Mount the CLX-DIN-AP3 as
shown in the illustration on this page. The flanges of the
plates should not overlap other plates or lighting modules
that are mounted in the enclosure.
Once the CLX-DIN-AP3 is mounted to the automation
enclosure, two cables (supplied) must be connected as
shown in the illustration on this page. The 6 in (153 mm)
cable (4519362) connects the CAEN-BLOCK Cresnet
port to the DIN-AP3 Cresnet port. The 18 in (457 mm)
flat cable (4519661) connects the CAEN-BLOCK to the
CLX module connector.
For wiring of the CLX-DIN-AP3, refer to the DIN-AP3
Installation and Operations Guide (Doc. 7491) and
DIN-HUB Installation and Operations Guide (Doc. 6671)
at
www.crestron.com/manuals.
Example of CLX-DIN-AP3-HUB Location and Orientation
CLX-DIN-AP3 Specifications
SPECIFICATION
DETAILS
Height 7 3/8 in (188 mm)
Width 14 in (356 mm)
Depth 3 in (77 mm)
Weight
CLX-DIN-AP3
CLX-DIN-AP3-HUB
2.3 lb (1.1 kg)
2.7 lb (1.3 kg)
Further Inquiries
To locate specific information or resolve questions after
reviewing this guide, contact Crestron's True Blue
Support at 1-888-CRESTRON [1-888-273-7876] or, for
assistance within a particular geographic region, refer to
the listing of Crestron worldwide offices at
www.crestron.com/offices.
To post a question about Crestron products, log onto
Crestron’s Online Help at
www.crestron.com/onlinehelp.
First-time users must establish a user account to fully
benefit from all available features.
CLX Module
DIN-AP3
CAEN-BLOCK
DIN-HUB
6 in (153 mm)
Cable (4519362)
18 in (457 mm)
Flat Cable
(4519661)
DIN-PWS30-277


Produkt Specifikationer

Mærke: Crestron
Kategori: Ikke kategoriseret
Model: CLX-DIN-AP3

Har du brug for hjælp?

Hvis du har brug for hjælp til Crestron CLX-DIN-AP3 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Crestron Manualer

Crestron

Crestron HZ2-AUX Manual

7 Oktober 2025
Crestron

Crestron PW-2407WUL Manual

29 September 2025
Crestron

Crestron C2N-UNI8IO Manual

28 September 2025
Crestron

Crestron CLXI-4HSW4 Manual

24 September 2025
Crestron

Crestron GLD-LED-50W Manual

24 September 2025
Crestron

Crestron TPS-4LW Manual

23 September 2025
Crestron

Crestron Zūm Manual

23 September 2025
Crestron

Crestron SIMPL Manual

23 September 2025
Crestron

Crestron UC-FCM-T Manual

23 September 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer