Introduction
A redundant power supply provides a low-cost, simple
solution to the equally simple yet vexing problem of internal
power supply failure, which can result in the shutdown of a
single switching device or an entire network.
With a redundant power supply connected, an integrated
detection circuit continuously monitors the switch’s internal
power supply. In the event of a power interruption, the
redundant power supply is immediately triggered so that the
switch and connected devices can continue providing
service.
This results in a more reliable network infrastructure and
protects the network from a single failure of a network
device power supply.
Description
The DPS-200, DPS-300, DPS-500, DPS-500DC, DPS-600
and DPS-700 are redundant power supply units designed to
conform to the wattage requirements of the switches being
supported. DPS-200 operates at 60 watts; DPS-300
operates at 90 watts, DPS-500/500DC at 140 watts, DPS-
600 at 500watts, and the DPS-700 at 589 watts.
The DPS-200, DPS-300, DPS-500, DPS-500DC, and DPS-
600 can connect to the master switch using a 14-pin DC
power cable. Similarly, the DPS-700 uses a 22-pin DC
power cable. A standard, three-pronged AC power cable
connects the redundant power supply to the main power
source.
Single RPS (DPS-200/DPS-300
/DPS-500/DPS-500DC)
Single RPS (DPS-
600/700)
14-pin DC power cable
22-pin DC power cable
Installation of the RPS
The single RPS DPS-200, 300, 500, and 500DC can be
installed to the standard rack via the RPS rack DPS-800
and DPS-900. DPS-900 is a standard-size rack mount (5U
in height) designed to hold up to 8 redundant power
supplies. The DPS-800 is also a standard-size rack mount
(1.25U in height) designed to hold up to 2 redundant power
supplies. Installed RPS units can be DPS-200s, DPS-300s,
DPS-500s, DPS-500DCs, or a combination of the above.
NOTE: The DPS-500DC can only be
inserted into a DPS-800
Installing a DPS-
600/700 in a standard
electronics rack
Inserting a single
RPS into a DPS-800
RPS rack
Installing a DPS-800 in a
standard electronics rack
Inserting a single
RPS into a DPS-900
RPS rack
Installing a DPS-900 in a
standard electronics
rack


Produkt Specifikationer

Mærke: D-Link
Kategori: bryter
Model: DPS-600
Vægt: 3500 g
Opbevaringstemperatur (T-T): -40 - 70 °C
Relativ luftfugtighed ved drift (H-H): 10 - 90 %
Driftstemperatur (T-T): 0 - 50 °C
Dimensioner (BxDxH): 441 x 139 x 44.5 mm
Certificering: FCC Class B, CE, UL, CUL
Gennemsnitstid mellem fejl (MTBF): 100000 t
Total effekt: 500 W
Strømforsyningenhed (PSU) formfaktor: 1U

Har du brug for hjælp?

Hvis du har brug for hjælp til D-Link DPS-600 stil et spørgsmål nedenfor, og andre brugere vil svare dig




bryter D-Link Manualer

D-Link

D-Link DAP-X3060OU Manual

23 Januar 2025
D-Link

D-Link DGS-1100 Manual

23 Januar 2025
D-Link

D-Link DGS-1024T Manual

23 Januar 2025
D-Link

D-Link DGS-1016S Manual

23 Januar 2025
D-Link

D-Link DGS-3224TGR Manual

23 Januar 2025
D-Link

D-Link DES-1026G Manual

21 Januar 2025
D-Link

D-Link DPS-600 Manual

26 December 2024
D-Link

D-Link DWL-3200AP Manual

25 December 2024
D-Link

D-Link DES-3250TG Manual

25 December 2024
D-Link

D-Link DIS-100G-S5W Manual

24 December 2024

bryter Manualer

Nyeste bryter Manualer